The JK-

82 “Oasis” wireless alarm kit

 

2/2 

MKE58105 

 

2. 

Install the JA-83P PIR motion detector about 2 to 2.5 meters above 
the  floor,  select  its  reaction  via  the  relevant  internal  DIP  switch 
(INS/DEL), connect its battery up and close the cover. 

+

1

23

45

6

78

9

12

3

tab

strap

 

To  observe  EN  50131-2-2  the  battery  in  the  JA-83P  must  be  fixed  with  the 
supplied strap and the tabs must be secured by the supplied screw. 

3. 

Plug the JA-80L siren into

 a mains power socket 

5.  Enrolling more wireless devices 

The  system  can  be  extended  with  more  wireless  devices  (a maximum  of 
50 can be enrolled). To enroll another device, the CP should be in service 
mode, if it is not enter 

 0 8080 

(while the system is unset) 

1. 

On the keypad, key in 

1 to enter enrollment

 mode 

2. 

The  next 

vacant  address  is  displayed

  (scroll  to  other  addresses 

using the 

&

 7

  keys if desired) 

3. 

Connect  up  the  device’s  battery  to  enroll  the  device  to  the  CP. 
Successful  enrollment  is  confirmed  by  the  A  indicator  lighting.  The 
next vacant address is then displayed. 

  The RC-86 key-fob can also be enrolled by pressing and holding a 

pair of its buttons 

+

 (or 

+

4. 

Exit enrollment mode 

by

 pressing the # key.

 

 

To enroll the CP to 

UC-82 or AC-82 modules, enter 299

 while the 

CP is in service mode with the receiving module in enrollment

 

mode. 

6.  Testing device functionality  

1. 

The CP should be in Service mode, if not enter 

 0 8080

 

2. 

First  trigger  the  device  under  test

  (e.g.  a  detector).  The 

keypad

 

(with its flip cover open) 

then indicates

 triggering of the device if the 

device is functioning correctly and is enrolled. 

  Motion  detectors  are  best  tested  within  15  minutes  of  closing  their 

covers  as  after  that  they  only  react  to  frequent  movements  once 
every 5 minutes (to restart a device’s test mode, open and close the 
detector housing again). 

 

7. 

Checking a device’s radio signals 

1. 

The CP must have its antenna connected and should be in Service 
mode, if not enter 

 0 8080

 

1. 

Enter 298

, the lowest address with enrolled device will be displayed 

2. 

Trigger the device

 

linked to

 

this address 

– the keypad (with its flip 

cover open) then 

shows

 

the device’s signal strength in the range ¼ 

to 4/4 (it should be at least 2/4, if not, relocate the device)   

  Motion detectors are best tested within 15 minutes of closing their 

covers  as  after  that  they  only  react  to  frequent  movements  once 
every 5 minutes (to restart a device’s test mode, open and close 
the detector housing again). 

  To test the JA-81F keypad signal, trigger the connected magnetic 

door sensor or activate the keypad’s tamper sensor. 

  To test the JA-

80L siren signal, press the siren’s button. 

3. 

To select the 

next enrolled device

 

address

 use the 

&

 7

 

 keys.

  

4. 

To 

exit 

signal

 

measurement mode, press the

 #

 key. 

8.  Programming the system 

1. 

The CP should be in Service mode, if not enter 

 0 8080

 

2. 

Enter the appropriate programming sequences to select the desired 
functions  (a  complete  list  of  them  is  in  the  CP  and  communicator 
manuals) 

 
 

 

Function 

Sequence 

Note 

New 

service code

 

5 xxxx 
xxxx 

Factory default: 8080  
xxxx = new code 

Exit delay 

20x 

x=multiples of 10 sec. (e.g. 205 = 50 
sec).  
Factory default:  30s 

Entrance delay 

21x 

x=multiples of 5 sec. (e.g. 204 = 20 
sec.). 
Factory default: 20s 

Alarm duration 

22x 

x=1 to 8=1 to 8 minutes 
9 = 15min. 
Factory default: 4 min 

Tel. numbers for event 
reporting to telephones 
 

81 M xx.x  

M

 = memory 1 to 8 

Factory default reports: 

M1 & 2 alarms by SMS 
M3 & 4 alarms by SMS+call 
M5 & 6 alarms by SMS+call & 

setting/unsetting by SMS 

M7 alarms by call 
M8 faults by SMS  

xx..x

 = tel. number 

81 M 

0 erases memory M 

Forwarding of incoming 
SMSes to the first 
programmed phone 
number 

801 x 

x = 1 enabled (factory def.)  
x = 0 disabled 

Time and date entry 

4 hh mm DD MM YY

 

 

 

9.  Testing GSM communication  

1. 

Program 

your mobile phone number to memory M1

 

2. 

Exit Service mode 

via the

 #

 key and press both buttons on the key-fob 

to trigger a 

Panic alarm

 

– an alarm SMS should be sent to your mobile.  

3. 

End the Panic alarm

 by pressing the 

button on the key-fob. 

4. 

Call the SIM card number 

(it is shown in the alarm SMS report). Wait 

until the call is answered by the CP (beep in the phone) and enter a valid 
service code (factory default: 8080)  

5. 

Your  phone  keypad 

should  now

 

work  the  same  way  as  the  system 

keypad 

– test it. 

6. 

End the call

 

7. 

Erase y

our mobile’s number from M1 and program it into M8 if you wish 

to receive reports of technical troubles in the system in future. 

10. Editing keypad text strings  

1. 

The CP should be in 

Service mode

, if not enter 

 0 8080

  

2. 

Press and hold the

 

?

 

key

 to enter editing mode. 

        Keys

:  

1 & 7 

are for the selection of 

text strings, 

 

 

3 & 9 

scroll through 

characters and numbers

4 & 6 

move the 

cursor

2 erases 

the

 

highlighted

 

character, 

# exits 

editing mode.

 

Editing  text  only  affects  the  text  in  that  particular  keypad. 

A

 

more 

convenient way of text editing is with a PC running Olink software. 

11. Finishing off the installation 

1.  Exit  service  mode  via  the  #  key  and  demonstrate  clearly  how  to 

operate the system to the user(s). 

2.  Recommend the user to change the default master 1234 code to 

a new master code. 

 

Entry 

Function 

code / card 

Setting/unsetting (arming and disarming) 

ABC 

Complete arming (all sections) 

Partially setting A (if used) 

Partially setting AB (if used) 

Reading the event memory (4 scrolls backwards) 

Changing the MASTER code/card (e.g. *5 1234 2789 2789) 

To create a new user code/card (e.g. *6 1234 03 3344 programs 
user code number 3, to erase the code enter: *6 1234 03 0000) 

7 code/card 

To secretly signal operation (unsetting) under duress 

8 a 

PGX and PGY control (if used) 

0 MASTER 

code 

Maintenance mode (testing, overview of codes, bypassing,…) 

Exiting maintenance mode or terminating an incomplete entry 

Displays  status  details  (triggered  detectors,  fault  causes  or  the 
status of PG outputs …..) 

 
 
 
 
 
 
 

 