Installation using the mounting base: 

 

If it is not possible to provide concealed and secure placement for 

the connecting cables (for example cables running out of a wall), 
then it is recommended to place them in a supplementary 

mounting base 

(included)

 

onto which the camera will be fixed later 

on. 

 

 

Figure 5: camera installation on the ceiling with an installation base 

1.  Select an adequate place considering the best camera view  

of the protected area and cable routing. 

2.  Use the sticker with the mounting base drilling layout to mark all 

mounting holes. 

3.  Using a Ø 6mm drill bit to drill the holes and put dowels from 

the accessory pack in them. Prepare a hole through which you will 
push the connecting cables (through the centre or from the side). 
Use a grommet (see the accessory pack) for the prepared hole and 
put a blind flange into the unused hole. 

4.  Push the cable in the mounting base and screw it on using the two 

supplied screws. If you want to use a grommet on the cable, put  
it on beforehand and then push the data cable through. 

 

Slide the connector sheath, sealing sleeve and a locking nut  
on the cable, see Figure 6. The last step is to take a crimping tool 
and press the RJ-45 connector onto the data cable. 

5.  Disassemble the camera housing by unscrewing the 3 Torx T15 

screws (included in the accessory pack).  

Caution: 

The

 

front cover of the camera is fixed to the base  

by a flexible cord during installation. Open the housing carefully. 

6.  Connect the RJ-45 connector to the camera. Fix the connection  

by a waterproof sheath with a bayonet closure (included 

 

in the accessory pack) and tighten the locking nut, see Figure 6.  
If the nearest router or switch used does not support the PoE 
function (power over Ethernet), connect the camera via the power 
connector to an 12 V DC / 500 mA external power supply. 

7.  Fix the camera base to the mounting base using 3 metric screws 

using a Torx key. Mind the correct position of the camera, see  
the notch in figure 3. 

8. Perform camera registration (see the chapter: 

Registration  

to a server

) to obtain access to preview and align the camera  

in the required direction, allowed in three axes, see figure 3. 

9.  Close the camera front cover and screw it on. Remove  

the protective foil and using the rag supplied in the accessory 
pack clean up the camera removing impurities and fingerprints 
etc. 

Installation of camera without a mounting base:

 

If the camera is going to be installed at a place where all  

the connecting cables are protected against tampering (for example 
a lowered ceiling, drywall ceilings and wall partitions etc.), then  
the camera can be mounted on a flat surface directly and cables 
with connectors put through the prepared hole.    

Warning:

 A waterproof sheath (cover) has to be put on the cable 

before pressing the RJ-45 data connector. 

 

Figure 6: assembling the waterproof sheath of the LAN connector; 

1 – camera connector (bayonet closure); 2 – O-ring; 3 – RJ plug/connector;  

4 – waterproof sheath; 5 – sealing sleeve; 6 – locking nut; 7 - cable 

Power

 

Permanent powering of the camera is required and can be realized  

in two ways: 

a)  Powering via data cable called PoE (Power over Ethernet),  

the switch or router has to support it. The voltage (48 V)  
is standardized by the IEEE 802.3af network norm. This has a big 
advantage; the camera is powered directly via the data cable. 

b)  An external 12 V/500 mA power supply connected to the 2.1 mm 

connector of a camera. This way requires an extra cable for 
powering separately to the data cable. The advantage is that  
the camera can be backed up by an appropriate backup power 
supply.  

Caution:

 When a backup power supply is used to power the camera 

when a mains power outage occurs, it is also necessary to have all 
devices providing internet connection and data transfer to Internet 
backed up (routers, switches, modems, wireless transmitters, etc.). 

Camera connection to LAN network

 

Video data transfer is based on continuous communication with 

the Jablotron server to which data is sent. Set up the DHCP 
function to be used in the local network. Communication ports 
between the camera and the JABLOTRON cloud are 443, 8883 
and ports range from 8000 to 8500. When your network is pre-set 
as usual, it is not necessary to modify any parameters of the 
firewall or router. 

Caution:

 The camera is not physically connected to the JABLOTRON 

100 system, it doesn´t occupy any positions. Power from the alarm 
system is not required and the camera status is not monitored.  

Registration to a server

 

Registration can be performed from the web or a smart 

application for cell phones by entering the unique camera MAC 
address on the label stuck on camera body or on its box. It can also 
be scanned by QR code. Every camera can be registered to only 
one JALOTRON 100 system. There is a 30 minute time-out after 
power is connected when the camera can be registered. When this 
time frame expires then registration can be repeated by voltage 
restart. 

Registration procedure:  

1. 

Connect the power to the camera (initialisation takes approx. 1 minute) 

2. 

Log in to the MyCOMPANY application and open the „INSTALLATION 
MANAGEMENT“ module. 

3. 

Select the installation to which you want to register the camera. 

4. 

Go to the CAMERAS tab and click onto REGISTER A CAMERA 

5.  Fill in the MAC address of the camera and the name which will  

be displayed in MyJABLOTRON and click onto “REGISTER“. 

6.  When registration is confirmed in MyCOMPANY, in the following 

24 hours the installer can watch a live preview from this camera. 
Permanent livestreaming is available in the MyJABLOTRON 
application for the end user. 

Caution:

 Because of security reasons it is impossible to record 

data to another storage system (like local NVR, etc.). Access  
to the camera’s internal settings is blocked. 

MyCOMPANY programmable options: 

Click the configuration symbol of a specific camera in the list  

of available cameras. 

There the following parameters are to be set: 
The

 Quality of videostreaming

 option changes the image quality. 

By clicking the button a camera setting change is performed. 
The parameter has a big influence on the recorded video quality and 
the amount of data transfer to the server (uploading). 

Activation of video sequence for a section 

– by checking those 

options you pre-set from which sections and for what type of events 
video sequences are stored. 