jablotron JB-EXT-TH-R Manual Download Page 2

JB-EXT-TH-R Wireless outdoor temperature detector 

JB-EXT-TH-R Wireless outdoor temperature detector 

2 / 2 

MTQ51101 

Batteries replacement 

The system sends a report automatically when the batteries are 

low. During the battery replacement it is not necessary to switch the 
system to service mode (this detector has no tamper contact).  

After taking out the battery, press the discharging button (4)  

to discharge the capacitors in the detector and then insert  
a new battery.  

Apply the same procedure if you need to enroll the detector  

to a different control panel. Only one battery can be used in the 
detector. To prolong the detector lifetime use another battery 
CR123A. When using two batteries always replace both batteries in 
the same time and use the same type and brand of fully charged 
batteries.   

External sensor JA-TS-PT1000 

The external sensor is not included in the JB-EXT-TH-R package. 

The length of the conductors is 3 m and can be extended. However 
the conductor extension can cause a measurement deviation. 
Follow the recommended wire gauges listed below when extending 
the conductors. 

Wire length 

10 m 

20 m 

30 m 

Minimal wire gauge 

0,5 mm

2

 0,8 

mm

2

 0,8 

mm

2

 

Measurement deviation 

+ 0,1 °C 

+ 0,15 °C 

+ 0,2 °C 

Table 1:  External sensor JB-TS-PT1000 extension 

Technical parameters 

Power 

 2x Lithium battery type CR123A (3.0 V/1500 mAh) 

 

Please note: Batteries are not included 

Current consumption (nominal/maximal) 

15 

μ

A/50 mA 

Typical battery lifetime 

(applies if the electronics are placed in  

a non-condensing environment with temperature of 0 °C to +30 °C 
and relative humidity of 10% - 90% rH). 

Sensor type / number of batteries 

1x CR123A  2x CR123A 

Internal 

5 years 

10 years 

External (JB-TS-PT1000) 

2 years 

4 years 

Low battery reporting 

< 2.4 V 

Communication band 

868.1 MHz, JABLOTRON protocol 

RF range 

up to 200 m (open area) 

Dimensions 

90 x 110 x 35 mm 

Weight 145 

Internal sensor temperature measurement range 

-25 °C to +60 °C 

External sensor temperature measurement range  -50 °C to +200 °C 
Operational temperature 

-25 °C to +60 °C 

Internal sensor temperature measurement range accuracy  ±0.6 °C 
External sensor temperature measurement range accuracy 

±1 °C 

IP coverage 

IP53 

Also complies with  

 ETSI EN 300 220, EN 60950-1,  

 EN 

50130-4, 

EN 

55022 

 

 

 

 

JABLOTRON ALARMS a.s. hereby declares that the 

JB-EXT-TH-R  

is in a compliance with the relevant European union harmonisation 
legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 
2011/65/EU. The original of the conformity assessment can be found  
at 

www.jablotron.com

 - Section Downloads.

 

 

Note:

 Although this product does not contain any harmful materials 

we suggest you return the product to the dealer or directly  
to the producer after use. For more detailed information visit 
www.jablotron.com

 

 