background image

JA-84P wireless motion detector with built-in camera 

 

JA-84P_en_PTS1 

The JA-84P wireless motion detector with built-in camera 

 

 

The  JA-84P  is  a  component  of  Jablotron’s  Oasis  80  alarm  system.  It 
provides  human  body  movement  detection  including  visual  alarm 
verification. The detector’s camera is equipped with a flash to take photos 
in the dark. The camera is capable of taking monochromatic pictures with 
a  resolution  of  160x128  pixels.  A  sequence  of  4  photos  is  taken  when 
movement is detected. It is stored in the detector’s internal memory and it 
is  also  transmitted  wirelessly  to  the  control  panel  to  be  sent  to  an  alarm 
receiving center and/or to the owner’s mobile phone display. The battery-
powered detector communicates via the OASIS radio protocol. 
 

 

 

Recommended control panel configuration 

To  transfer  photos  from  the  protected  premises,  the  control  panel 

should  be  equipped  with  a  suitable  communicator  (model  JA-80Y  = 
GSM/GPRS  software  version  XA61006  or  higher  or  JA-80V  = 
LAN/PSTN  software  version  XA64004  or  higher)  and  with  the    JA-
80Q  data  processing  module  connected  to  the  communicator’s 
internal bus cable.  

The communicator allows for the programming of an IP address to which 

the  photos  will  be  transferred  (see  the  corresponding  communicator 
installation  manual).  As  a  factory  default,  Jablotron’s  photo  server  (IP 
address 

195.39.77.154, 

port 

7070) 

are 

preprogrammed 

which 

corresponds  to  the  URL 

http://img.jablotron.cz

.  This  server  allows  the 

logging into and display of the photos free of charge. It can also notify you 
by SMS  message  when  a new photo  arrives, providing  a  link to  view the 
photo  on the phone  display. The server can  also forward the photos to  a 
desired e-mail address.  

If  the  control  panel  is  not  equipped  with  a  suitable  communicator  and 

data processing module (JA-80Q), photos will only be stored locally in the 
detector’s internal memory (last 61 shots). 

Multiple camera detectors 

can be enrolled to the control panel. If more 

of  the  detectors  take  photos  within  a  very  short  period  of  time,  the 
detectors will transfer the photos to the control panel in the same order as 
the detectors were triggered. 

 

Installation and testing of the motion detector 

Installation should only be undertaken by technicians holding a certificate 
issued by an authorized distributor. The detector can be installed on a flat 
wall  or  in  the  corner  of  a  room.  Avoid  objects  rapidly  changing  in 
temperature,  such  as  electrical  heaters,  gas  appliances  etc.  being 
positioned  within  its  detection  area.  Moving  objects  with  a  temperature 
close  to  that  of  humans  such  as  curtains  moving  above  a  radiator,  and 
pets  should  also  be  avoided.  Detectors  should  not  face  windows  or 
spotlights  or  be  near  fast-moving  air  e.g.  near  ventilation  fans  or  open 
windows  or  doors.  There  should  also  be  no  obstacles  blocking  the 
detector’s  “view”  of  the  protected  area.  Keep  the  detector  away  from 
metal objects which could interfere with radio communication. 

 

1. 

Open  the  detector  cover 

by  pressing  the  tab  and  disconnect  the 

camera’s flat cable (pulling from the connector by the batteries) 

2. 

Remove  the  PCB 

which  is  held  by  an  internal  tab.  Avoid  touching  

the PIR element 

3. 

Punch  screw  holes  through  the  rear  plastic  cover. 

At  least  one 

screw  should  penetrate  the  tamper-sensitive  section  (be  careful  not 
to break the tamper sensitive section out).   

4. 

Screw  the  rear  cover  to  the  wall, 

about  2  meters  above  the  floor 

(vertically, with the tab down).  

5. 

Replace the PCB 

to its original position. 

6. 

Leave  the  battery  disconnected  and  the  cover  open 

(camera 

disconnected) and then follow the control panel manual to enroll the 
detector. The basics of enrollment are: 

a.  Enter  enrollment  mode  on  the  control  panel  by  pressing    “1” 

while in Service mode. 

b. Install batteries into the detector to activate enrollment. 

If  the  detector’s  batteries  have  already  been  connected,  first 
disconnect  them  ,  press  and  release  the  tamper  switch  and  then 
reconnect the batteries  

c.  Exit enrollment mode by pressing “#”  

d. Leave the control panel in SERVICE mode.  

7. 

Connect the camera cable and close the detector’s cover. 

If the 

red  LED  is  permanently  lit,  it  means  that  the  motion  detector  is 
warming  up  (it  usually  takes  about  100  sec.  after  the  batteries  are 
connected).  If  the  red  LED  is  flashing,  the  detector  has  not  been 
enrolled yet (see point 6). 

8. 

After the red LED turns off 

test the motion sensor by walking in the 

covered  area (detected movement is indicated by red LED flashes). 
Also test the detector’s radio signal strength – see the control panel 
installation  manual  for  details.  Testing  is  only  possible  within  15 
minutes of closing the detector’s cover. After this period the red LED 
is switched off.  

9. 

If  the  detector  is  not  in  test  mode,  it  ignores  frequent  movements 
(see the following section).   

5 minute / 1 minute sleep time 

 To  save  battery  energy,  the  detector  switches  to  battery-saving  mode  15 
minutes  after  its  cover  is  closed.  The  detector  still  watches  for  movement 
during battery-saving mode.  

 The first movement detected is instantly transmitted to the control panel, and 

for the next 5 minutes the detector ignores

 any further 

movement

 After these 5 minutes, the detector then returns to watching out for movement 
until it is re-triggered. The sleep time can be shortened to 1 minute by pressing 
the  tamper switch  during  battery installation. Not pressing  the tamper switch 
gives a sleep time of 5 minutes. 

Camera testing 

Switch  the  control  panel  to  SERVICE  mode  and  have  an  RC-80  key-fob 
ready. 

1. 

Open  and close the detector’s cover  again.  Its

 green indicator  will 

turn  on

  for  10  sec  (enrollment  mode  to  enroll  the  key-fob  as  a 

remote trigger for testing the camera)  

2. 

Enroll  the  key-fob  by pressing  any key (a  green LED flash confirms 
enrollment)   

3. 

Use  the  key-fob  to  take  photos: 

  =  snap  without  flash

  = 

snap with flash

    

4. 

Camera  test  mode  lasts  for  15  minutes  then  the  key-fob  is 
automatically  erased  from  the  detector.  If  you  want  another  15 
minutes testing, repeat the above procedure starting from 1. 

After it has been taken the 

photo is transmitted

 to the control panel - 

indicated  by 

green  LED  flashing

.  Successful  transmission  is  confirmed 

by a long green flash (2 sec). Unsuccessful transmission is indicated by a 
series  of  rapid  green  flashes  at  the  end.  The  transmission  is  also 
indicated on the JA-80Q data module (same logic).    

After  the  photo  is  received  by  the  control  panel,  the  data  module 

transfers it to the server (via the communicator). This transfer is indicated 
by  a  red  LED  flashing  on  the  JA-60Q  module.  Successful  transfer  is 
confirmed  by  a  long  red  flash  (2  sec).  Unsuccessful  transfer  is  indicated 
by a series of rapid red flashes at  the end. 

The  total  average  time  to  transfer  the  photo  from  the  camera  to  the 

server is about 20 sec. In the case of radio signal interference the transfer 
can be longer (damaged  data  are repeated). Each photo  also contains  a 
date and time stamp. 

If the  photo transfer  was not successful, the photo  will  only stay  in  the 

detector’s internal memory.  

Normal camera operation  

15  minutes  after closing the cover, the  detector changes from test  mode 
to  normal  operational  mode  (the  test  key-fob  is  erased  and  the  red  LED 
turns off). 

If  the  control  panel  is  unarmed  (unset), 

the  detector  ignores 

movements and takes no photos. 

During  the  exit  delay 

the  detector  reports  movements  but  takes  no 

photos. 

During  the  entrance  delay

  the  detector  –  when  triggered  –  not  only 

reports  a  movement  but  also  instantly  takes  one  photo  without  a  flash. 

Reviews: