DIP Switch 1 Selection - Immunity to false alarms.
The NORM (OFF) down position combines very good immunity
with fast sensor reactions.
The HIGH (ON) up position gives increased immunity with a slower
reaction time and is only used for problematic installations.
DIP Switch 2
Leave in ‘ON’
up position
We recommend using a high quality brand name battery (e.g. Duracell, Panasonic). After the batteries have been replaced, detector function
should be tested.
After battery replacement, the detector needs about 3 minutes to stabilise during which its LED lights continuously. After the LED has stopped
indicating, test the detector’s functioning.
If a partly discharged battery is inserted then the LED starts flashing for one minute. The LED will stop flasing when a brand new battery is installed.
Expired batteries should be disposed of according to local regulations.
Battery
Type:
1
x
CR123A
Lithium
Voltage:
3.0V
DC
Typical battery life:
Approx. 3 years (5 min. sleep mode)
Communication
band:
868
MHz
Communication range:
Approx. 300M (open area)
Recommended installation height:
2.0 to 2.5 M above floor level
Detection angle/detection range:
120° / 12 M (basic lens)
Operational environment according to EN 50131-1
II.indoor general
Operational temperature range:
-10 to +40 °C
Dimensions:
85 x 60 x 55 mm
EN 50131-1, CLC/TS 50131-2-2, EN 50131-5-3 classification:
Grade 2
Complies with:
ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1
Can be operated according to:
ERC REC 70-03
15 minutes after closing the detector cover, the indicator shows
detector activation.
5 minutes / 1 minute sleep time
To save battery energy, the detector switches the battery to battery-
save mode 15 minutes after its cover is closed. During battery-save
mode the detector will still detect movement. The first movement
detected is then signalled to the receiver, and for the next 5 minutes
the detector ignores any further movement. After the 5 minutes
the detector then returns to watching out for movement until re-
triggered. The sleep time can be shortened to 1 minute by pressing
the tamper switch during battery installation and programming. Not
pressing the tamper switch gives a sleep time of 5 minutes.
Note: When adding the time element ‘Step 3’ of programming,
the recommended time is >5 minutes if the sleep mode is
set to 5 minutes, or >1 minute is the sleep mode is set to 1
minute. This ensure the PIR is active at all times.
The default lens supplied covers an angle of 120° and a distance
of 12 metres. The area is covered by three beams as shown in the
following pictures.
DIP Switches
Testing the Detector
Battery Replacement
Detection Characteristics
Technical Specifications