7.4. Selection of events to report to ARCs 

This sequence allows you to select which events are reported to the ARC: 

05 p uu x 

where:  

 

p

 

1 = ARC1, 2 = ARC2 

uu

 

Event numer 00 to 97  

x

 

0 = no report, 1 = report 

 

Factory default setting:  

See the table below 

Event 

CID CODE 

Factory default 

settings 

uu 

Alarm after powering up the system 

1140/3140 

reported 

00 

Instant loop alarm  

1130/3130 

reported 

01 

Delayed loop alarm  

1134/3134 

reported 

02 

Fire alarm 

1110/3110 

reported 

03 

Panic alarm 

1120/3120 

reported 

04 

Tamper alarm 

1144/3144 

reported 

05 

Number of permitted incorrect code- 
entries exceeded 

1461/3461 

reported 

06 

Device fault  

1330/3330 

reported 

07 

Complete setting 

3401 

reported 

08 

Complete unsetting 

1401 

reported 

09 

Codeless setting  

3408 

reported 

12 

Partial setting A 

3402 

reported 

13 

Detector communication failure 

1350/3350 

reported 

14 

Control panel power supply dropout  

1301 

reported 

15 

Control panel power supply restored  

3301

 

reported 

16

 

Detector power supply dropout  

1384/3384

 

reported 

17

 

Communicator failure  

1330

 

Not reported  18

 

Communicator OK 

3330

 

Not reported  19

 

Control panel battery failure  

1302

 

reported 

20

 

Control panel battery OK  

3302

 

reported 

21

 

Alarm 24h 

1130

 

reported 

23

 

Receiver jamming 

1355

 

reported 

24

 

Setting A 

– split system 

3402

 

reported 

26

 

Setting B 

– split system 

3402

 

reported 

27

 

Unsetting A 

– split system 

1402

 

reported 

28

 

Unsetting B 

– split system 

1402

 

reported 

29

 

Setting C 

– split system 

3402 

reported 

30 

Unsetting C 

– split system 

1402 

reported 

31 

Partial setting AB 

3402 

reported 

33 

Power supply ON 

3301 

Not reported  64 

Switching to service /  
maintenance mode 

1306 

reported 

65 

Exiting service / maintenance mode   

3306 

reported 

66 

End of alarm indication 

*

 

Not reported  67

 

Reporting to ARC1 

*

 

reported 

68

 

No reporting to ARC1 

*

 

reported 

69

 

Reporting to ARC2 

*

 

reported 

70

 

No reporting to ARC2 

*

 

reported 

71

 

Alarm cancelled by user 

1406

 

reported 

78

 

Control panel reset 

1305

 

Not reported  79

 

All tampers calm  

3137

 

reported 

80

 

All faults removed  

3300

 

Not reported  81

 

System power supply OK  

*

 

Not reported  82

 

The communicator has no connection  

1356

 

reported 

83

 

Communicator connection restored 

3356

 

reported 

84

 

Master code reset to 1234 

1305

 

Not reported  85

 

Master code changed  

*

 

Not reported  86

 

Power supply failure exceeding  
30 minutes 

1301 

reported 

89 

Unconfirmed alarm  

1138

 

reported 

90

 

Service request 

1393

 

reported 

91

 

PgX output ON  

1661

 

Not reported  92

 

PgX output OFF  

3661

 

Not reported  93

 

PgY output ON  

1662

 

Not reported  94

 

PgY output OFF  

3362

 

Not reported  95

 

Blocking after an alarm  
(Engineer reset) 

1500

 

reported 

96

 

Unblocking after an alarm  

3500

 

reported 

97

 

Low SIM card credit balance  

*

 

Not reported  50

 

SMS transmission from a line  
(e.g. from JA-84P) 

-

 

Not reported  51

 

ARC communication failure 

1354

 

reported 

52

 

ARC communication restored 

3354

 

reported 

53

 

tab. 3 ARC event table 

Source 

Name 

701 

Control panel  

731 

Communicator 

741 

Keypad 

001 - 050 

Device 1 

– Device 50 

500 

Master code 

599 

Service code 

501 - 550 

Code 1 

– code 50 

tab. 4 Source number table 

The report to the ARC consists of:  

 

Premises number, event code, section, source number. 

 

Section: 01 is set for all reports  

 

Split system for setting and unsetting: 02 = A, 03 = B 

 

Unsplit system for partial setting: 01=ABC,

 

02 = A, 03 = AB 

Notes: 

 

Events to ARC are reported with the identification of the section 

7.5. ARC communication checking 

– periodic or fixed  

This sequence is used to define whether the regular transmission takes place at a 
given  time  according  to 

07  p  hhmm

,  or  periodically  according  to 

07  p  hhmm

 

settings. 

06 p x 

where:  

p

 

1=ARC1, 2=ARC2 

x

 

0= with a period according to 

07 p hhmm

 

 

1= at the set time according to 

07 p hhmm

 

 

Factory default setting:  With a period after the last report 

7.6. ARC communication checking period 

This sequence programs how often the communication check is performed: 

07 p hhmm 

where: 

p

  

1 = ARC1, 2 = ARC2 

hh

 

hours 

mm

 

minutes 

Notes:  

 

Checking reports are not sent in service mode. 

 

Jablotron  IP  protocol  allows  very  frequent  checking  of  ARC  communication 
(even every 5 minutes in practice). 

 

When 00:00 is set, communication check is not performed. 

Factory default setting: 23:59 (hours:mins) 

7.7. Enable ARC reporting (ARC2 backs up ARC1) 

This sequence allows reporting to ARCs to be switched on/off and also enables 
ARC2 to backup ARC1: 

08 p x 

where: 

p

 

1=ARC1, 2=ARC2 

x

 

0=off,  1=on,  2=ARC2  backs  up  ARC1  (2  can  only  be  entered  for 
ARC2) 

Note:

 if ARC2 backs up ARC1 then it will only receive reports if it is not possible to 

deliver them to ARC1. Each event is first reported to ARC1 (both main and backup 
number / URL address) and if the transmission fails, the event is reported to ARC2.  
A report containing “Communication fault to ARC1” is then sent to ARC2 together 
with the first report to ARC2 
 

Factory default setting: Transmissions to both ARCs are off 

7.8. Recording ARC reporting in the control panel memory 

This sequence enables the recording of every report successfully communicated to 
ARCs in the control panel’s internal memory: 
 

001 0

  

disabled 

001 1

  

enabled 

 

Note:

 it is recommended not to record reports sent to ARCs via reliable protocols 

(IP CID and SMS CID) but to enable the indication of ARC communication faults 
(see 7.9). This saves a significant amount of control panel memory. The system 
initially assumes that every report is successfully delivered to ARCs, but if a report 
is  not  successfully  delivered  within  110  seconds  of  transmission,  then  a 
communication fault will be indicated and recorded. 

Factory default setting: disabled 

Summary of Contents for JA-82Y

Page 1: ...commend blocking the roaming feature in the SIM card to avoid unnecessarily high communication fees contact your GSM provider for details 3 User functions of the communicator The following text describes all communicator features The installer should show the end user how to operate the functions used in the particular installation 3 1 Event reporting to the user s phone The communicator reports e...

Page 2: ...M8 To program phone numbers to the M memories enter the following sequence while in Maintenance Service mode 81 M xxx x y 0 where M is memory number 1 to 8 xxx x is a telephone number max 20 digits y is a sequence for control via unanswered calls it does not have to be entered In a split system information from all sections ABC is reported to the 1st and 8th number positions sections AC to numbers...

Page 3: ...2 is programmed the code 2222 will be automatically inserted in an SMS with instructions sent from the first number stored in the memory Factory default setting No code 6 7 Allowing remote access for telephone numbers Remote access is allowed for numbers saved in positions 1 to 8 Programming sequence 85 M x where M memory position tel numbers 1 to 8 x parameter 1 to allow access parameter 0 to den...

Page 4: ...ation off 907 1 synchronization on Factory default settings on 6 18 Phone receiver loudness To set the loudness of the receiver of the phone which is used to call the communicator key in 909 x where x is a number from 1 to 9 max Factory default setting 9 max 6 19 Number to be called to maintain SIM card validity If a prepaid SIM card is used and a lack of outgoing phone calls for a certain period ...

Page 5: ...o the communicator turn on the control panel power and then enter the correct PIN code 920 PIN 0 and wait until the communicator registers to the GSM network its red LED should turn off within a minute The communicator memorizes the set PIN and it will use it automatically whenever it registers to the GSM network again If you are replacing the SIM card in the communicator with another one and the ...

Page 6: ... 97 Low SIM card credit balance Not reported 50 SMS transmission from a line e g from JA 84P Not reported 51 ARC communication failure 1354 reported 52 ARC communication restored 3354 reported 53 tab 3 ARC event table Source Name 701 Control panel 731 Communicator 741 Keypad 001 050 Device 1 Device 50 500 Master code 599 Service code 501 550 Code 1 code 50 tab 4 Source number table The report to t...

Page 7: ...ated by green LED 1 being permanently lit on the left under the SIM card holder see fig 1 Communicator description Transmission to the server is signalled by a flashing green LED Successful transmission is confirmed by a long green LED flash and unsuccessful transmission is reported by rapid flashes of the green LED Successful transmission from the GSM communicator to the server is confirmed by a ...

Page 8: ...ed in position 0 by the sequence 81 0 xxx x 0 xxx x own telephone number If you change the SIM card position 0 will be automatically erased Time synchronization see section 6 17 of the control panel is performed whenever entering into service mode or maintenance mode and if there is a difference greater than 5 minutes between the correct time and control panel time synchronization is performed aut...

Page 9: ... Incoming call Welcome to OASiS Enter your access code Valid code CODE Can t perform the operation Enter your access code OK Invalid Valid Disarmed system Press 1 to arm OK System Armed Armed system Press 2 to disarm OK System disarmed Service mode If the system is in the requested state terminate the call The 9 key pressed Keypad simulation ...

Page 10: ...witching to service maintenance mode 7 other event 66 Exiting service maintenance mode 7 other event 67 End of alarm indication 7 other event 78 Alarm cancelled by user S S S S S S S 7 other event 79 Control panel reset 7 other event 80 All tampers on standby 7 other event 81 All faults removed 7 other event 82 System power supply OK 7 other event 83 The communicator has no connection 5 fault 84 C...

Page 11: ... 702 Finish setting 406 Service mode 529 Internal communication error 703 Signal strength 407 Maintenance mode 530 Internal communication restored 704 Control 409 Battery discharged 531 Communication test 705 Bypass 410 Tamper alarm 532 Unconfirmed alarm 706 Test OK 411 Alarm memory 533 Blocking after an alarm 707 Test error 412 Fault 534 Unblocking after an alarm 708 0 4 413 Power supply fault 53...

Page 12: ...abled Enabling remote access 802 x x 0 no x 1 yes by phone and Internet x 2 yes but only by enrolled phones 1 yes Forwarding of incoming SMS messages 801 x x 0 no x 1 if the incoming text is not an SMS instruction it will be forwarded to the first programmed number in memories M1 to M8 yes Autoconfiguration of GPRS 903 x X 0 autoconfiguration disabled x 1 autoconfiguration enabled Autoconfiguratio...

Page 13: ...vent code see 7 4 x 1 report x 0 no report All events are reported see tab 3 Periodic or fixed ARC connection check 06 p x p 1 ARC1 p 2 ARC2 x 0 with a period from the last report according to the 07 p hhmm setting x 1 once a day at the time set by entering 07 p hhmm With a period after the last report X 0 ARC communication checking period 07 p hhmm p 1 ARC1 p 2 ARC2 hhmm hours minutes see setting...

Reviews: