background image

JA-80IR wireless optical barrier  

2 /2 

MKU52303

 

 

A permanently lit LED on the right indicates that the beam has been 

interrupted (or wrongly adjusted). The better the beam reception, the 

longer the breaks between the LED flashes. When the LED stops 

flashing, continue looking for the ideal position indicated by the highest 

voltage measured on the voltmeter. 

 

Setting up the electronic part of the barrier 

Both units are equipped with setting switches. The switch located on the side 

of the units (on the optical part) allows barrier beam modulation frequency 

adjustment from 1 to 4. This setting is useful only for a combination of 

multiple JA-80IR barriers where a problem with interference might appear. 

For more information see the original user. 

 

There is a DIP switch with five switches. The first two positions are used to 

set the reaction time to an interruption of the beam. The shorter the time, the 

more precise the interruption detection, but also the greater the susceptibility 

to false alarms during worsened optical conditions (snow, fog, ...)

 

 

Fig. 7 Reaction time setting 

 

It is possible to set a 2-minute sleep time after an alarm (beam 

interruption) in order to save batteries. This setting is done by switching 

switch no. 3 (receiver unit), or no. 1 (transmitter unit) to the ON position. 

Switches 4 and 5 (receiver unit), or better 2 and 3 (transmitter unit) are 

set as a default and you should leave them in the OFF position for the 

correct functioning of the device. 

 

Operation testing  

 

The LEDs on the barrier have the following indication functions 

 

Receiver 

Transmitter

Low battery LED 

Low battery LED

Alarm LED

Power LED

 

Fig 8 LEDs on the units 

 

The signal battery low LEDs flash when the batteries in the unit are low. 

Both batteries 

(SAFT LSH20 lithium batteries) 

should always be 

replaced at the same time.

 

The alarm LED flashes during beam blocking. 

The power LED flashes when the battery in the transmitting unit is OK. 

 

Receiver 

Transmitter

 

Fig. 9 Barrier function test 

 

Perform a barrier test in three places (A B and C). The setting is 

completed only if the barrier reacts successfully in all three positions. 

You should also check the signal transmission to the system control 

panel. Only then is it possible to put back the unit covers and secure 

them. 

 

 

Checking the status of and replacing batteries 

 

The detector checks battery status automatically and if the batteries are 

running low, it informs the system. The detector remains fully functional.  

The batteries should be replaced as soon as possible (within 1 week). 

Use 

SAFT LSH20 batteries exclusively

 and always replace both at the 

same time.  

 

Technical specifications 

 

Power supply 

4x LSH20 type lithium batteries (3.6 V 13 Ah)

 

Average battery lifetime 

approx. 3 years (with 120 s energy saving mode)

 

Operating frequency 

868 MHz

 

Radio range – distance from the control panel 

up to 300 m with direct visibility

 

Optex barrier parameters 

Distance (max.) between the barrier units 

60  m

 

Barrier installation height 

0.7  – 1.0 m

 

Object motion speed 

as set by user

 

Battery saving timer 

120 s

 

Enclosure 

IP55

 

Max. relative humidity of the environment  

95%

 

Weight  

1620 g

 

Environment according to EN 50131-1   

class IV

 

Operating temperature range 

-20°C to +60°C

 

Security grade

 

according to OPTEX

 

Comply with                            ETSI EN 300220, EN 50130-4, EN 55022, EN 60950-1 

Can be operated according to 

ERC REC 70 03

 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-80IR 

is in a compliance  with the relevant Union harmonisation 

legislation: Directives No: 2014/53/EU, 2014/35/EU, 

2014/30/EU, 2011/65/EU. The original of the conformity 

assessment can be found at www.jablotron.com -  Section 

Downloads. 

 

Note:

  Although this product does not contain any harmful 

materials we suggest you return the product to the dealer or 

directly to the producer after use. 

 

 

 

88,1

21

7

162,5

83

,5

 

Fig. 10 Unit dimensions 

 

 

 

Reviews: