4.1.5 CMS1 and CMS2 pages
In the communicator page, the user can:
Set main and backup IP addresses and ports
Enable CMS communication
Set CMS2 as a backup for CMS1
Enable recording of CMS data transfer to the events list
Set the periodic report interval and delay before re-transfer
Set the Object ID code
Set the Transfer Event filter – chose what events will be sent to the CMS
4.1.6 Logoff
You can logoff by clicking on the Logoff button. You will also be logged off automatically according
to the
Idle time for auto logoff
setting on the Communicator page.
5 Specification
Power supply
12V DC provided by the alarm control panel
Current consumption
40 mA
AUX outputs
dry contact, max. 100mA / 60V
INP input
reacts to connection to GND, max. voltage 15V
Complies with
EN 50131-1, Z1, EN 50136-1
Security grade
2 (low to medium risk)
Enviromental class
II indoor-general ( –10 to 40°C)
Safety
EN 60950
EMC
EN 55022, EN 55024, EN 50130-4
Hereby, Jablotron Ltd., declares that this JA-60WEB
is in compliance with the essential requirements
and other relevant provisions of Directive 1999/5/EC. (NV 426/2000Sb.)
Original of the conformity assessment can be found at the web page
www.jablotron.com
, section Technical support.
Note:
Although this product does not contain any harmful materials, we suggest you to
return the product to the dealer or directly to the producer after usage.
6 Programming sequence summary
Function
Sequence
Options
Factory default
DHCP setting
94y
y=0 ... DHCP disabled,
y=1 ... DHCP enabled
DHCP enabled
IP address setting
91 xxx xxx xxx xxx
xxx xxx xxx xxx is the IP
address
192.168.1.253
Netmask setting
92 xxx xxx xxx xxx
xxx xxx xxx xxx is the IP
address
255.255.255.0
Gateway IP setting
93 xxx xxx xxx xxx
xxx xxx xxx xxx is the IP
address
192.168.1.1
Reset 96060
Reset to factory default
settings possible
-
JA-60WEB communicator
-4 -
MHO51103