JA-60GSM communicator module
- 11 -
MFJ51212
•
Unsent event reports to a CMS are erased only in the case of a
telephone number, account ID or communication format change
•
Information about the end of fault events is transferred to the
monitoring station during programming mode
•
Changes of setting will take affect after exiting programming mode
9.4
The master code holder can change the following
parameters
•
•
•
•
•
•
•
Telephone numbers 1 – 7 (see section 3.1)
SMS and audible warning transfers (see section 4)
Change of remote user code
One-time
dialing
in
Measuring of GSM signal
Attached phone functionality
Telephone number for emergency calls
10 Technical specifications
power
12VDC / max. 1A – provided by the alarm control panel
GSM bands
E-GSM/GPRS 900/1800MHz
transmitted power
2 W for GSM900, 1 W for GSM1800
AUX output
dry contact, max. 100mA / 60V
comply with
EN 50131-1, EN 50136-2-1, 2-3, 2-4
security grade 2 (low to medium risk)
environmental class II indoor-general ( –10 to 40°C)
safety
EN
60950
EMC
EN 301489-1, EN 301489-7, EN 55022, EN 50130-4
radio characteristics ETSI EN 301419-1, EN 301511
Caller line identification presentation (CLIP) ETSI EN 300 089 V3.1.(2000-12)
Can be operated according to commission decision 2000/299/EC
Hereby, Jablotron Ltd., declares that this JA-60GSM is
in compliance with the essential requirements and
other relevant provisions of Directive 1999/5/EC.
Original of the conformity assessment can be found at the web page
www.jablotron.cz, section Technical support.
Note: Although this product does not contain any harmful materials we
suggest you to return the product to the dealer or directly to the
producer after usage.