jablotron JA-60GSM Installation Manual Download Page 11

 

JA-60GSM communicator module 

 

 

- 11 - 

MFJ51212

 

 

Unsent event reports to a CMS are erased only in the case of a 
telephone number, account ID or communication format change

 

 

Information about the end of fault events is transferred to the 
monitoring station during programming mode 

 

Changes of setting will take affect after exiting programming mode 

9.4 

The master code holder can change the following 
parameters 

 

 

 

 

 

 

 

Telephone numbers 1 – 7 (see section 3.1) 
SMS and audible warning transfers (see section 4)

 

Change of remote user code 

 

One-time 

dialing 

in

 

Measuring of GSM signal

 

Attached phone functionality 
Telephone number for emergency calls 

 
 

10 Technical specifications 

 

power 

12VDC / max. 1A – provided by the alarm control panel 

GSM bands 

E-GSM/GPRS 900/1800MHz 

transmitted power 

2 W for GSM900, 1 W for GSM1800 

AUX output 

dry contact, max. 100mA / 60V 

comply with                     

EN 50131-1, EN 50136-2-1, 2-3, 2-4 

security grade                                                                  2 (low to medium risk)     
environmental class                                          II indoor-general ( –10 to 40°C) 
safety  

 

EN 

60950 

EMC 

EN 301489-1, EN 301489-7, EN 55022, EN 50130-4 

radio characteristics                                           ETSI EN 301419-1, EN 301511 
Caller line identification presentation (CLIP) ETSI EN 300 089 V3.1.(2000-12) 
Can be operated according to commission decision 2000/299/EC

 

 

Hereby, Jablotron Ltd., declares that this JA-60GSM  is 
in compliance with the essential requirements and 
other relevant provisions of Directive 1999/5/EC. 

 

Original of the conformity assessment can be found at the web page 
www.jablotron.cz, section Technical support. 

 

Note: Although this product does not contain any harmful materials we 
suggest you to return the product to the dealer or directly to the 
producer after usage. 

Summary of Contents for JA-60GSM

Page 1: ...elephone set can be attached to the dialer The PHONE output of the dialer should never be connected to any other telephone network g If you use the AUX output to control an appliance connect its cable to the AUX output terminals normally open dry contact max 100mA 60V see figure 1 S Y M BO L SPA C E CANCEL MENU NAMES CALLS WRITE READ 1 2 3 4 5 6 7 8 9 0 2 S MS C A LL MUT E FLASH REDIAL SPEAKER fig...

Page 2: ...y an SMS reply If the alarm system is split the instruction will effect the section which belongs to the access code used If arming without a code is enabled on the control panel the AM command can be used without any access code In this case the command performs the same action as the keys F 1 pushed on a keypad 2 5 Disarming by SMS DM xxxx Command DM followed with a valid access code will disarm...

Page 3: ...JA 60GSM dialer module 3 MFJ51212 2 10 ...

Page 4: ...e a From an authorized phone dial the JA 60GSM phone number The SP 01 will ring once and then it will answer the call b Potential alarm on the control panel will be terminated c You can talk to the premises d For switching to the listening mode press 5 on your phone For switching back to the talking mode press key 2 Or by pressing button 1 it is possible to toggle between talking and listening e P...

Page 5: ...ther with each corresponding index number It also shows which events are assigned to which telephone numbers to be reported by SMS You can make your own setting by using 81 uu t y where uu is the event index from 01 to 31 see table 4 1 1 t is a telephone number memory location from 1 to 8 y 0 reporting disabled 1 reporting enabled Note SMS reports consist of 4 text parts installation name event na...

Page 6: ...ireless detector 15 14 No code arming 416 Wireless detector 16 15 External communication failure 501 User code 1 16 External communication recovery 502 User code 2 17 Failure 503 User code 3 18 Failure recovery 504 User code 4 19 AC failure longer than 30 minutes 505 User code 5 20 AC failure 506 User code 6 21 AC recovery 507 User code 7 22 Battery failure 508 User code 8 23 Battery recovery 509 ...

Page 7: ...RF jamming 29 Internal communication failure 30 Internal communication recovery 31 Periodic test Example if you enter 820381 and a Fire alarm is triggered event index 03 the dialer will call the 8 th telephone number and it will play audible warning if the call is answered 4 4 Temporarily disabling SMS and audible reports If you need to disable all SMS and audible reports temporarily to all teleph...

Page 8: ...to the first ring of any incoming call Without requesting the access code it will enable the calling phone s keypad to be used as the keypad of the alarm system F N This mode will be disabled after you dial in or after you exit programming mode 5 9 GSM signal monitoring Enter 971 on the alarm system keypad in programming mode to measure the GSM signal strength The keypad will show a number from 0 ...

Page 9: ...mming mode in the communicator using ComLink software 5 17 GSM module reset Enter 976 to disconnect and connect the GSM module to the GSM network This function is useful when it is necessary to switch the mobile device off and on e g when the SIM card has been unblocked by the mobile operator It is also possible to send the command via SMS in the form yyyyy GSM where yyyyy is service access code T...

Page 10: ...ng two independent CMSs 7 9 Storing the event data to CMS sent into the event memory By this sequence it is possible to disable recording of the event that indicates that data to a CMS has been sent to the list of event in the control panel Programming sequences 090 The CMS data transfer event is not recorded 091 The CMS data transfer event is recorded Default setting The CMS data transfer event i...

Page 11: ... bands E GSM GPRS 900 1800MHz transmitted power 2 W for GSM900 1 W for GSM1800 AUX output dry contact max 100mA 60V comply with EN 50131 1 EN 50136 2 1 2 3 2 4 security grade 2 low to medium risk environmental class II indoor general 10 to 40 C safety EN 60950 EMC EN 301489 1 EN 301489 7 EN 55022 EN 50130 4 radio characteristics ETSI EN 301419 1 EN 301511 Caller line identification presentation CL...

Page 12: ...st ring without the access code Measuring of GSM signal 971 If entered while in programming it shows GSM signal strength from 0 to 9 Volume adjustment of the connected phone 974x 975x Level adjustment of received and outgoing signal from 1 to 9 5 medium level GSM Module Reset 976 If entered while in programming mode the GSM module will be disconnected from and connected to the GSM network It is al...

Reviews: