jablotron JA-60GSM Installation Manual Download Page 1

JA-60GSM dialer module 

Installation manual 

 

The JA-60GSM dialer is constructed for the JA-60, 63 and 65 alarm control panels. The dialer is used for communication via GSM. An 

appropriate GSM provider is chosen according to the inserted SIM card. This Installation manual is intended for the JA-60GSM, version FJ61409.  

 

The GSM module, when installed in the alarm control panel, enables:  

 

Automatic sending of an event’s text messages to up to 8 mobile phones 

 

Dialing of programmed telephone numbers and playing of an audible warning signal  

 

Data transfer to one or two Central Monitoring Stations (CMS)  

 

Remote control and programming of the alarm system via SMS instruction messages from a mobile phone or from Jablotron’s SMS 
website 

 

Remote control and programming of the alarm system using a telephone set keypad (mobile or land line)  

 

Remote control of an appliance (heating system etc.) via telephone (mobile or land line) 

 

Phone calls and convenient receiving and sending of SMS messages using an SMS-8010 telephone set (optional accessories; except 
GSM kits e.g.JK-05) attached to the dialer module (via the GSM network)  

 

Connection of the intercom SP-01 for communication with the premises 

 

Internet connection using the GPRS data transfer 

 

Programming of the alarm system via ComLink software 

 

Programming and remote supervision of the alarm system via Jablotron’s website www.gsmlink.cz

 

 

Installation of the dialer 

 

The JA-60GSM dialer can be installed into the telephone 
communicator’s position in a JA-60, 63 or 65 control panel  (either a 
GSM module or a telephone line communicator module can be used in 
a control panel – it is not possible to install both simultaneously).     

a) 

Disconnect

 the control panel’s 

power

 supply (both AC and 

backup battery).  If the control panel has been previously used 
before this installation, enter the programming mode before 
disconnecting the power supply.  

b)  We recommend you to 

disable the SIM card PIN code 

protection 

before you insert it into the dialer. Use a mobile phone 

to perform this task (if you have a NOKIA phone, select: Menu, 
Settings, Security settings, PIN code request, Off). If you insist on 
usage of the PIN, see section 

5.1

c) 

Open the SIM card holder 

(by sliding it in the direction shown in

 

figure 1

and

 Insert the SIM card

 into the holder 

and close it

 by 

sliding it back. – see figure 1. 

d)  Attach the dialer into the control panel case and connect its flat 

cable to the control panel’s main board.  

e) Connect 

the 

GSM antenna

 (never switch the power supply on 

without a proper antenna)  

f) Connect 

a

 SMS-8010 telephone set

 to the PHONE connector (or to 

PHONE terminals) if desired. Only one telephone set can be attached 
to the dialer. The PHONE output of the dialer should never be 
connected to any other telephone network. 

g)  If you use the 

AUX output

 to control an appliance, connect its 

cable to the AUX output terminals (normally open dry contact, 
max. 100mA / 60V) – see figure 1. 

 

 

S

Y

M

B O

L

SPA C E

CAN CEL

MENU

N AMES

C ALLS

WRITE

R EAD

1

2

3

4

5

6

7

8

9

0

#

2

S M S
C A L L

M UT E

FLAS H

R EDIA L

SP EAK ER

 

figure 1

 

 

 
Note: if your control panel supports programming of the PgX and 
PgY outputs for the AUX function (sequences 238 and 239), the 
appliance can also be controlled wirelessly from the control panel 
by incorporating a UC-216 or UC-222 receiver module into the 
system. 

h) 

Reconnect the control panel’s power supply

 (backup battery 

and AC). The system will show a 

P

, (programming mode). The red 

LED on the GSM dialer will light permanently (indicating that the 
module is establishing a connection with the GSM network). The 

LED will switch off after the connection is successfully 
established

.   

If the LED starts flashing, the module was not able to connect to 
the GSM network. In this case, switch off the control panel’s power 
completely. Remove the SIM card and insert it into a mobile phone 
to confirm whether it is possible to connect to the network at this 
location. You can also select a desired network manually if options 
are available. Ensure that the SIM card does not request a PIN 
code (optional use with a PIN code is described in section 5.1). 
Once the SIM card works in the mobile phone, reinsert it into the 
GSM dialer and repeat step h). If the GSM signal is weak in this 
area, change the location of the GSM antenna before you try to 
reestablish the connection. 

i) 

Attach the control panel’s cover after the module has connected to 
the GSM network (LED switched off). 

j) 

Enter 971

 on the alarm system keypad (while in programming 

mode) to 

monitor the GSM signal

. The keypad will show a 

number from 0 to 9 and it will sound a beep every second 
indicating a new measurement. For proper functioning of the dialer 
the signal strength should be 3 or higher. Find the best location for 
the antenna while measuring the signal strength. To switch the 
system 

back to programming

 mode press the 

N

 key.   

k) 

Without additional programming you can 

test the user features

 of 

the dialer (phone calls from an attached phone, remote control of 
the system via a remote phone, remote control of an appliance 
etc.). See the following description. 

l) 

Set telephone numbers

 for automatic event reporting and the 

other selectable features – see part 3. 

m) 

Programming of the GSM dialer

 is possible by entering 

programming sequences via the alarm system’s keypad (while in 
programming mode). The most convenient programming method, 
however is via a connected PC using Comlink software, or by 
using the www.GSMlink.cz website. 

JA-60GSM dialer module 

- 1 - 

MFJ51212 

Summary of Contents for JA-60GSM

Page 1: ...elephone set can be attached to the dialer The PHONE output of the dialer should never be connected to any other telephone network g If you use the AUX output to control an appliance connect its cable to the AUX output terminals normally open dry contact max 100mA 60V see figure 1 S Y M BO L SPA C E CANCEL MENU NAMES CALLS WRITE READ 1 2 3 4 5 6 7 8 9 0 2 S MS C A LL MUT E FLASH REDIAL SPEAKER fig...

Page 2: ...y an SMS reply If the alarm system is split the instruction will effect the section which belongs to the access code used If arming without a code is enabled on the control panel the AM command can be used without any access code In this case the command performs the same action as the keys F 1 pushed on a keypad 2 5 Disarming by SMS DM xxxx Command DM followed with a valid access code will disarm...

Page 3: ...JA 60GSM dialer module 3 MFJ51212 2 10 ...

Page 4: ...e a From an authorized phone dial the JA 60GSM phone number The SP 01 will ring once and then it will answer the call b Potential alarm on the control panel will be terminated c You can talk to the premises d For switching to the listening mode press 5 on your phone For switching back to the talking mode press key 2 Or by pressing button 1 it is possible to toggle between talking and listening e P...

Page 5: ...ther with each corresponding index number It also shows which events are assigned to which telephone numbers to be reported by SMS You can make your own setting by using 81 uu t y where uu is the event index from 01 to 31 see table 4 1 1 t is a telephone number memory location from 1 to 8 y 0 reporting disabled 1 reporting enabled Note SMS reports consist of 4 text parts installation name event na...

Page 6: ...ireless detector 15 14 No code arming 416 Wireless detector 16 15 External communication failure 501 User code 1 16 External communication recovery 502 User code 2 17 Failure 503 User code 3 18 Failure recovery 504 User code 4 19 AC failure longer than 30 minutes 505 User code 5 20 AC failure 506 User code 6 21 AC recovery 507 User code 7 22 Battery failure 508 User code 8 23 Battery recovery 509 ...

Page 7: ...RF jamming 29 Internal communication failure 30 Internal communication recovery 31 Periodic test Example if you enter 820381 and a Fire alarm is triggered event index 03 the dialer will call the 8 th telephone number and it will play audible warning if the call is answered 4 4 Temporarily disabling SMS and audible reports If you need to disable all SMS and audible reports temporarily to all teleph...

Page 8: ...to the first ring of any incoming call Without requesting the access code it will enable the calling phone s keypad to be used as the keypad of the alarm system F N This mode will be disabled after you dial in or after you exit programming mode 5 9 GSM signal monitoring Enter 971 on the alarm system keypad in programming mode to measure the GSM signal strength The keypad will show a number from 0 ...

Page 9: ...mming mode in the communicator using ComLink software 5 17 GSM module reset Enter 976 to disconnect and connect the GSM module to the GSM network This function is useful when it is necessary to switch the mobile device off and on e g when the SIM card has been unblocked by the mobile operator It is also possible to send the command via SMS in the form yyyyy GSM where yyyyy is service access code T...

Page 10: ...ng two independent CMSs 7 9 Storing the event data to CMS sent into the event memory By this sequence it is possible to disable recording of the event that indicates that data to a CMS has been sent to the list of event in the control panel Programming sequences 090 The CMS data transfer event is not recorded 091 The CMS data transfer event is recorded Default setting The CMS data transfer event i...

Page 11: ... bands E GSM GPRS 900 1800MHz transmitted power 2 W for GSM900 1 W for GSM1800 AUX output dry contact max 100mA 60V comply with EN 50131 1 EN 50136 2 1 2 3 2 4 security grade 2 low to medium risk environmental class II indoor general 10 to 40 C safety EN 60950 EMC EN 301489 1 EN 301489 7 EN 55022 EN 50130 4 radio characteristics ETSI EN 301419 1 EN 301511 Caller line identification presentation CL...

Page 12: ...st ring without the access code Measuring of GSM signal 971 If entered while in programming it shows GSM signal strength from 0 to 9 Volume adjustment of the connected phone 974x 975x Level adjustment of received and outgoing signal from 1 to 9 5 medium level GSM Module Reset 976 If entered while in programming mode the GSM module will be disconnected from and connected to the GSM network It is al...

Reviews: