Notes: 

A mini USB cable is not in the supplied accessories of the siren, 
control panel or any other device. You can use the cable from 
the JA-190T card reader. We strongly recommend connecting 
the USB cable straight to the PC connection as using a USB 
HUB can reduce the reliability. 

According to the changes which have been done during the 
update, previous settings might stay or settings could be erased 
to default. When a reset has been done you can reload the 
previous settings by the 

Import

 button and restore them with no 

negative influence on the new firmware. 

Internal settings of the siren 

The  siren  properties  can  be  set  in  the 

Devices

  window  of  the  F-Link 

software. When  at  the  siren  position,  use  the 

Internal settings

  option  to 

open a dialog window, internal setting is separated into 2 tabs: 

Settings

 and 

PG indication

 (default settings are marked *): 

Settings tab: 
Sections: 

to set for which sections the siren should indicate an alarm, 

as  well  as  setting  the  chirps.  The  default  setting  is  indication  for  all 
sections disabled.

 

Reaction: 

defines  whether  the  siren  should  indicate 

EW*

  (external 

warning) or 

IW

 (internal warning). Alarm indication can also be disabled 

completely (other functions remain enabled). 

Siren  sound:

  intermittent*,  continuous.  Option 

intermittent

  saves 

energy. 

Maximum siren time:

 1, 2, 3*, 4, 5 minutes.  

Acoustic signalling in a section:

 selection of the sections for which 

other  sounds  mentioned  below  will  be  produced.  Default  setting  is  no 
section selected.

 

 

 

Enabling of any here-mentioned options causes 
a  reduced  battery  life  time  depending  on  the 
frequency of its use. That´s why we recommend 
fitting the BAT-100A second battery. 

 

Higher  volume:

  YES / NO*  -  affects  only  entrance / exit  delay 

indication and sounds indicating PG output triggering. It doesn´t have any 
influence on the sound of an alarm. 

Beeps during section control:

 YES / NO – if enabled, the siren chirps 

once after setting, twice after unsetting and three times when unsetting 
after an alarm. It only does so when the option 

Periodical communication

 

is set to 1 s. 

Warning  indication:

  YES / NO*  -  When  enabled  the  siren  will  beep 

three times to indicate: 

1)  inability to set (a system status which prevents setting, such as a 

fault or a triggered detector)

 

2)  unsuccessful  setting  (an  event  occurs  during  exit  delay,  e.g.  a 

triggered detector)

 

3)  unsetting with alarm memory (an alarm occured)

 

Entrance  delay  beeping:

  YES / NO*  if  enabled,  it  indicates  the 

entrance delay for the whole entrance time – intermittent beeping. 

Exit  delay  beeping  with  a  partially  set  system:

  YES / NO*  -  if 

enabled,  it  indicates  the  entrance  delay  for  the  whole  time  when  the 
system  has  been  partially  set  –  intermittent  beeping.  This  option  is 
available when 

Entrance delay beeping

 is enabled. 

Exit delay beeping:

 YES / NO* - if enabled, it indicates the exit delay 

for the whole exit time when the system is fully set – intermittent beeping. 

 

Optical indication: 

 

Flashes every 60 seconds:

 YES / NO* - It sets to one siren flash per 

minute. It can be used as a warning that the building is protected by an 
alarm system. 

When controlled by a section:

 YES / NO – it sets a siren to optically 

indicate  setting  and  unsetting  of  (a)  section(s).  It  blinks  once  when  set 
and it blinks twice when unset and when unset after an alarm then three 
blinks. This option is available only if the periodical communication is set 
to 1 s. 

 

LED indication:

 red*/ blue, sirens are equipped with dichromatic LED 

indicators.  According  to  the  colour  of  the  bought  front  cover  it  is 
necessary to set the same colour of indication for LEDs. 

Siren flashing options: 

During alarms*/ 1/ 3/ 5/ 30/ 60 min of flashes 

after an alarm. This option sets the length of siren flashing for only the 
alarm time or extended for by a pre-set interval. Extended flashing can be 
terminated by new system setting or cancellation of alarm indication in the 
system (with a keypad). 

Periodical  communication:

  1 s / 8 s  –  This  parameter  sets  the 

maximum postponed reaction of the siren to an alarm. When the option 
8 s  has  been  selected,  then  it  is  not  possible  to  enable  set / unset 
indication. 

Sounds  upon  loss  of  RF  communication

:  YES / NO  -  When 

enabled,  the  siren  sound  when  there's  no  connection  with  the  control 
panel longer than 1hr 50min (110 min). Length of sounding depends on 
"Maximum siren time". "No limitation option" means 20 minutes. 

 

Notes: 

PG output activation sometimes might not be indicated when 
periodical communication is set to 8 s and a PG output is 
switched ON for a shorter time than 8 s. 

When periodical communication is set to just 1 s it can reduce 
the typical battery lifetime by half. 

 

PG output indication: 

The siren can indicate the activity of selected PG outputs with its chirps. 

Chirp 1

 – slow chirping - 1 per second (for the whole period when the 

PG is active) 

Chirp 2

 – rapid chirping - 2 per second (for the whole period when the 

PG is active) 

Chirp 3

 - 1 chirp when the PG is activated, 2 chirps when the PG is 

deactivated  

Chirp 4

 – a long 20 sec chirp when the PG is activated 

 

Settings according to security grade 2 

To set the siren to comply with security grade 2 use F-Link SW, the 

Parameters tab and the option “Perform EN50131-1”. Device will be 
configured according to required properties. 

Sound priorities  

The siren sound has the highest priority, the control chirps have a lower 

priority and the PG output activity indication has the lowest priority (PG1 
has a higher priority than PG2 etc). A chirp with a higher priority always 
terminates chirping with a lower priority. 

 

External antenna use 

To improve the communication quality between the control panel and 

the outdoor siren you  can connect  an  external antenna  (AN-868).  Plug 
the antenna into the connector (15) on the PCB. Detection of a connected 
antenna is performed only when the cover is open (active tamper). If an 
antenna  is  connected  during  closing  the  siren  cover,  it  is  automatically 
used for radio communication. If the antenna is shorted out or cut off, it 
automatically switches to the internal antenna and a tamper alarm is sent. 
When  the  siren  cover  is  closed  with  no  external  antenna,  the  internal 
antenna is used for radio communication. 

Battery replacement 

The  product  checks  the  battery  status  automatically.  When  a 

battery  fault  is  triggered,  the  system  informs  its  user  (or  service 
technician).  The  siren  remains  fully  functional,  but  we  strictly 
recommend to replace the battery within 2 weeks. Don´t charge the 
battery  at  all.  Use  the BAT-100A  type  only.  The  battery  can  be 
changed in control panel service mode by a service technician. When 
replacing  is  finished,  test  the  siren’s  functioning.  Take  the  used 
battery to an official collection point, don´t throw it into the trash. 

 

Technical specifications 

The  JA-163A  parts  (lithium  battery,  front  cover  and  base)  are 

supplied individually. The reason is the free selection of a wide range 
of a front covers and the transportation of lithium batteries. 
 

Power 

Lithium battery 3.6 V / 13 Ah type BAT-100A 

 

(up to 2 batteries can be used) 

 

Please note: battery is not included 

Consumtion (normal / alarm state) 

0.3 / 1000 mA 

Battery low voltage 

”

 2.8 V 

Typical battery lifetime 

approx. 5 years (for basic settings) 

Communication frequency 

 868.1 MHz, JABLOTRON protocol 

Communication range 

approx. 300 m (open area) 

Antenna 

internal, external can be used, type AN-868 

Activation lost integrity 

acoustic tamper alarm (110 min) 

Piezo electric siren 

 

100 dB/m 

Dimensions (cover included) 

200 x 300 x 70 mm 

Weight 

434 g 

Classification 

security grade 2 / environmental class IV 

- according to  

EN 50131-1, EN 50131-4, EN 50131-5-3 

- environment 

general outdoor 

- operational temperature range 

-25 to +60°C 

- power supply 

type W 

- operational humidity 

75%  (95% 30 days) RH, non-condensing 

- certification body 

Trezor Test s.r.o. (no. 3025) 

Security grade 

IP44 

Also complies with 

ETSI EN 300 220, EN 50130-4, 

 

EN 55022, EN 60950-1 

Can be operated to  

ERC REC 70-03 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-163A RB is 
in  compliance  with  the  essential  requirements  and  other  relevant 
provisions of Directive 1999/5/EC and (EU) 65/2011.  The original of 
the  conformity  assessment  can  be  found  at 

www.jablotron.com

  - 

Technical Support section

 

 

Note:

  Although  this  product  does  not  contain  any  harmful 

materials  we  suggest  you  return  the  product  to  the  dealer  or 
directly to the producer after use. For more detailed information 
visit 

www.jablotron.com

.

 

  

Reviews: