JA-155E, JA-155E-GR, JA-155E-AN Wireless four-segment keypad with 

display and RFID reader 

Typ: 5KPAD2202LU 

JA-155E, JA-155E-GR, JA-155E-AN 

2 / 3 

MLU510701 

Alternative power supply 

The keypad can be supplied from an external power supply with 

12 V DC connected in PWR a GND terminals, see figure no. 5. You 

can use the DE 06-12  Power adaptor suitable  for concealed 

installation. If the alternative power supply is connected, leave the 

batteries inserted to ensure operation in the event of a mains power 

failure or an external power supply being disconnected. The inserted 

batteries are not recharged by an  external power supply. If an 

external power supply is connected, a permanent indication can be 

switched on. 

Installation of a magnetic contact 

The keypad supports connection of a door detector. The IN input 

reacts to being disconnected from the common GND terminal, see 

figure no. 5. The control panel´s reaction to an activated IN input is 

configurable in the F-Link SW. The input has a status response. 

 

PWR

  – red, positive pole of an external power 12 V DC 

GND

  – black, negative pole of an external power supply 

IN

   – green, input terminal for door (magnetic) contact 

GND

  – black, input terminal for door (magnetic) contact 

 

Figure 5: 

magnetic contact connection

 

Changing the batteries 

The keypad automatically checks the status of the batteries, and if 

the battery voltage drops below the limit specified in the Technical 

Parameters section, the keypad informs the system that the batteries 

need to be replaced. Batteries should be replaced within 2 weeks of 

the low battery report. The control panel must be switched into 

Service or Maintenance mode before removing the keypad from the 

back part (otherwise a tamper alarm will be triggered). 

Note:

 In order to make sure the keypad works correctly, we recommend 

using batteries supplied by the distributor or other quality brand alkaline 

batteries.

 

The Settings tab

 

Acoustic indication 

It is set without dependence on the optical indication. The keypad 

can indicate alarms, entry and exit delays. The acoustic indication of 

the entry delay is silenced for the duration of the authorization. Exit 

delays and alarms are indicated until the end of the pre-set time 

period  unless the system indicator button (3)/keypad cover (5) is 

pressed. 

Volume

 - Adjusts the keypad volume level in three levels: 

Low, 

*medium and high

 

Alarms 

– continuous tone

 

Entry delay 

 

continuous tone

 

Exit delay

 – slow beeping

 

Exit delay when partially set

  –  slow beeping (disabled from 

default).

 

Segment status change

 – beeps once when a status is changed 

Function: 

RFID reader

 – In order to save energy, you can limit the reader´s 

operation with the following options: 

 

Permanently  ON

  –  The RFID reader is always ON.  This 

setting is valid only if the keypad is permanently powered from 

an external source, otherwise their RFID reader is always 

switched off automatically. 

 

Activated by pressing

  –  when the keypad is activated the 

RFID reader wakes up for 3 seconds.  

 

Disabled

 – the RFID reader is permanently disabled. 

 

Activated by pressing or authorization request

  –  the 

keypad wakes up after pressing a button on a keypad cover or 

by an authorization request. 

Optical indication 

System indicator / button (3)

  –  indicates the system status, 

according to the following priorities from highest to lowest:

 

1 – Service indication: 

1) 

Flashes yellow twice every 2 seconds

 – Service mode 

2) 

Flashes green 2x every 2 seconds

 – Maintenance mode 

3) 

Slow flashing yellow

 – Keypad is in BOOT mode, which is 

used when updating firmware 

2 – Operational indications:

 

1) 

Flashing yellow

 – Keypad is not enrolled into system 

2) 

Rapidly flashing red

 – Alarm in system 

3) 

Flashes red 2x every 2 seconds

 – Alarm memory indication 

4) 

Flashes yellow (8 Hz)

 – Unsuccessful setting indication 

5) 

Permanent yellow light

 – Fault 

6) 

Flashes green (2 Hz)

 – Authorized user 

7) 

Permanent green light 

– Normal operation. Everything is OK, 

no faults 

3 – Combined indication:

 

1) 

Flashes alternately green / red

  –  Authorized user and 

alarm / alarm memory indication 

2) 

Flashes alternately green / yellow

 – Authorized user and an 

active fault indication 

4 – Indication in power save mode:

 

1) 

Flashes red once every 2 seconds 

–  Alarm memory 

indication for keypad in power save (sleep) mode (only valid 

for system profiles EN 50131-1 and Incert) 

2) 

Flashes yellow once every 2 seconds

  –  Fault indication 

(only valid for system profiles EN 50131-1 and Incert).  

3) 

No indication

 – Sleep mode 

Segments

 – there is no indication if the system is in the service 

mode or if the segment has no function programmed. The PG optical 

indication on the segment can be inverted.  

Keypad indication is adjustable in six levels: 

1. 

Indicates permanently 

–  the keypad indicates 

permanently. When the mains power to the control panel is 

disconnected it switches to a lower indication level. Then the 

mains power is restored the keypad indicates permanently 

again. 

2. 

Section / PG status change on keypad

  –  the keypad 

indicates when the section / PG status changes. The change 

of state is indicated only on that segment. Entry delay and 

alarm is indicated by the entire keypad. 

3. 

Section / PG status change on segment 

-  the keypad 

indicates when the section / PG status changes. Segment 

status change, arrival delay and alarm are indicated only on 

that segment. 

4. 

Segment status change on keypad 

– the keypad indicates 

when the segment status changes (setting, unsetting, 

PG on, PG off). The status change is indicated only on the 

segment. 

5. 

Entry delay / Alarm on segment

 – the keypad indicates the 

entry delay and alarm on a specific segment. 

6. 

Wake-up by pressing

 – the keypad optically indicates only 

after opening the front cover (5), pressing a key or segment. 

Other optional functions: 

 

Indicates PG status changes 

 

Indicates Unset status 

 

Indicates Set status 

 

External input  –  enables the input for an external magnetic 

contact 

Unset a section by authorization only during entry delay

  - 

using an access code or an RFID tag/card will unset a section where 

an entrance delay has been triggered (if the user has access to the 

section).  

WARNING

: This function is not recommended when the control 

panel is configured to use a Common section. Unwanted unsetting 

may occur to all sections assigned to the Common section or it may 

even occur to the whole system (when pressing the Unsetting button 

is followed by authorization). 