The JA-154E Wireless access module with LCD, RFID and keypad
The indication of the common segment is: all segments set = green,
some set (partially set) = yellow, all sections fully set = red.
Automatically shutting down the module
The module saves its energy by shutting down the optical
indication of system status, keypad backlight and RFID reader 10
sec. after its last activity with a user. The keypad still keeps
communication with the control panel and it can signal for example:
an entrance delay. Complete waking up is done when you press
the cover of the keypad, otherwise by activation of the magnetic
door contact connected to the IN terminal (see next paragraph).
When the parameter „
Entrance delay time and alarm are
triggering the keypad
“ (default) is enabled, the keypad is also fully
woken up when these events occur.
Disabling this parameter gives you a longer battery life time. In
this case the keypad cannot wake itself and will not indicate the
system status optically, and acoustic signalling can be delayed a
few sec.
Alternative power
The keypad can be powered from an external 12V DC power
supply via the PWR and GND terminals. The DE 06-12 power
supply has the advantage of hidden installation. The keypad does
not sleep if external power is used. It permanently communicates
with the control panel and it indicates the system status according
to the
Devices / Internal settings.
Leave the batteries inside the
keypad. When the mains power is cut off, the keypad will work from
the batteries.
Connection of an external door detector
The keypad has an input terminal for external door detector
connection. The input (IN) reacts to disconnection from the
common ground. The reaction of this input is delayed, and is linked
to the keypad address. The input has a status reaction. According
to the settings, the keypad can be completely woken up by
triggering the external detector.
Caution: this type of waking up is good to use when the keypad is
powered from the external power supply otherwise every activation
tends to shorten battery lifetime.
Battery replacement
The system automatically reports a Low Batt from the keypad.
Before you change the batteries, switch the system to service mode,
otherwise a tamper alarm will be triggered.
Unit modifications
If you need to change the segments (add or take out), release them by
levering on both sides of the segment near the buttons. When you have
finished changing the amount of segments the new JA-192Es are not
always immediately visible in the F-Link software. For synchronization,
click on the
Upload
button.
Note:
If there is a request to modify the keypad hardware, always
remove the batteries and disconnect the external power supply.
FW upgrade
1. Upgrades can only be done by a Service technician.
2.
F-Link
software is necessary for upgrades.
3. Start the F-Link in Off-line mode and open the appropriate
database.
4. Open the keypad by pressing on the tabs (6).
5. Remove the batteries and possible external power supply.
6.
Connect the miniUSB cable to the USB port on the PC.
(Caution: the miniUSB is not in the accessories of the keypad,
control panel or any other device. You can use the cable from
the JA-190T card reader. We strictly recommend connecting
the USB straight to the PC, connection via a USB HUB can
reduce the reliability.
7. Press and hold the backlit activation button (3).
8. When the button (3) is pressed, connect the miniUSB cable to
the connector on the module (11).
9. Switching to the mode for upgrading firmware (according to the
version of the keypad in about 5 sec.) is indicated by the yellow
LED flashing or by the backlit activation button flashing green
and yellow (now you can release the button (3)).
10. Then continue as if you are doing an upgrade via
F-link
software:
Control panel
ĺ8pgrade Firmware
ĺFKRRVHWKH
upgrade file pack (it is a part of the F-link installation pack, or it
can be independently published for downloading, file type
*.fwp)
11. F-Link shows a window with a device listing, select the USB
(typically at the first position).
12. Then press
OK
and perform the upgrade for the selected
device.
13. Disconnect the miniUSB cable, reinsert the batteries and
reassemble the keypad.
14.
Check the keypad via
F-Link
,
Devices/Internal settings
.
According to the changes which have been done during the
upgrade, previous settings might stay or settings could be
erased to default. When a reset has been done you can reload
the previous settings by the
Import
button and restore them
with no negative influence on the new firmware.
15. When the FW upgrade has been done, the main menu could be
expanded. In this case the new options are set to default.
Check their settings and adjust according to user requirements.
16. Perform a last check and try out the functions by some tests.
Technical specifications
Power
2 x alkaline batteries AA (LR6) 1.5 V 2400 mAh
Typical life time
1 - 2 year(s) according to the settings
Communication band
868.1 MHz, JABLOTRON protocol
Communication range
200 m (open area)
Power input from external supply
0.5 W
RFID frequency
125 kHz
Dimensions
102 x 145 x 33 mm
Weight 350
g
Classification
Grade II
According to
EN 50131-1, EN 50131-3, EN 50131-5-3
Operational environment
EN 50131-1 II. Indoor general
Operating temperature range
-10 to +40 °C
Also complies with
ETSI EN 300330, ETSI EN 300220
EN 50130-4, EN 55022, EN 60950-1
JABLOTRON ALARMS a.s. hereby declares that the
JA-154E
is
in compliance with the essential requirements and other relevant
provisions of Directive 1999/5/EC. The original of the conformity
assessment can be found at
www.jablotron.com
- Technical
Support section
Note:
Although this product does not contain any harmful materials
we suggest you return the product to the dealer or directly to the
producer after use. For more detailed information visit
www.jablotron.com
.
The JA-154E wireless access module with LCD, RFID and keypad
2 / 2
MLU56205