The JA-152SHM wireless shock or tilt detector with magnetic
contact
JA-152SHM
2 / 2
MLB55202
4.
Glow of yellow LED + rapid blinking of red LED = detector
calibration for approx. 4 s. Please calm the magnetic detector.
5.
Glow yellow LED + slow flashing red LED = detector is ready
for calibration. To continue, activate the detector by opening
and closing the window/door. Confirmation of detector
calibration will be indicated by the red LED lighting for approx.
1 s. Then the red LED will go out and the setup status will
change to complete, the yellow LED will still be lit.
Pulse mode:
Only activation of the detector is being sent to the control panel
unit.
Foreign magnetic field detection:
Once turned off, the device will
calibrate its magnetic tamper detector. Should it detect a foreign magnetic
field within its vicinity once its been calibrated, or a change in its own
magnetic field is detected, the detector will indicate input activation and
a fault.
Note:
When the foreign magnet detection is enabled, a window or
a door can only be opened in the direction in which the magnet movement
has been calibrated. Otherwise, the detector will indicate Activation and
fault. Therefore, this function cannot be used for windows or doors that
may be open in several ways (opening, tilting).
On:
Responds to a change in the contact connected to the input.
Simple balanced input:
Detection of 1 kΩ simply balanced lo
op of
external input or simple magnetic contact
Roller blind 1, Roller blind 2
– roller blind modes, responds to
repeated
and short opening pulses with sensitivity adjustable in two stages.
Shutter 1 = activation after 3 pulses within 2 minutes; Shutter 2 =
activation after 5 pulses within 2 minutes. If the input loop is interrupted
for more than 3 s, a tamper type alarm is generated. When using the INP
- Shutter 1 and INP - Shutter 2 modes, the module is idle for 10 s after the
activation is broadcast.
Detector testing
Optical indication is triggered with every activation when the system is
in service mode. Every single activation can be checked in
F-link
, on
the
Diagnostics
tab.
During normal operation, the optical indication is disabled.
Battery replacement
The system sends a report automatically when the battery is low.
Remember to switch the system to Service mode before changing
the batteries (otherwise a tamper alarm will be triggered). Check the right
function of the detector after battery replacement.
Technical specification
Power
1x alkaline battery type LR6 AA (1.5 V/2.4 Ah)
Please note: Battery is not included
Typical lifetime of battery
aprox. 2 years (20 activation per day)
Low battery voltage
<0.95 V
Current consumption in standby mode
74
μ
A
Maximum current consumption
80 mA
Communication band
868.1 MHz, JABLOTRON protocol
Maximum radio-frequency power (ERP)
18.2 mW
Communication range
cca 300 m (open area)
Maximum lenght of cable for external detector
3 m
Dimensions
24 x 109 x 24 mm
Dimensions of magnet
16 x 55 x 15 mm
Weight (w/o battery)
35 g
Classification
Security grade 2/Environmental class II
(according to EN 50131-1)
Operational environment
indoor general
Operational temperature range
-10 °C to +40 °C
Average operating humidity
75% RH, non-condensing
Certification body
Trezor Test s.r.o. (no. 3025)
According to
EN 50131-1, EN 50131-2-6, EN 50131-2-8,
EN 50131-5-3, EN 50131-6, ETSI EN 300 220-1,-2,EN 50130-4,
EN 55032, EN 62368-1, EN IEC 63000
Can be operated according to
ERC REC 70-03
Recommended screw
2 x
ø 3.5 x 40 mm (countersunk head)
JABLOTRON ALARMS a.s. hereby declares that the
JA-152SHM is in compliance with the relevant European Union
harmonisation legislation: Directives No: 2014/53/EU,
2014/35/EU, 2014/30/EU, 2011/65/EU, when used as intended.
The original of the conformity assessment can be found at
www.jablotron.com –
the Downloads Section
Note:
Disposing of this product correctly will help save valuable
resources and prevent any potential negative effects on human
health and the environment, which could otherwise arise from
inappropriate waste handling. Please return the product to the
dealer or contact your local authority for further details of your