background image

The JA-152SHM wireless shock or tilt detector with magnetic 

contact 

JA-152SHM 

2 / 2 

MLB55202 

4.

Glow of yellow LED + rapid blinking of red LED = detector

calibration for approx. 4 s. Please calm the magnetic detector.

5.

Glow yellow LED + slow flashing red LED = detector is ready

for calibration. To continue, activate the detector by opening

and closing the window/door. Confirmation of detector 

calibration will be indicated by the red LED lighting for approx.

1 s. Then the red LED will go out and the setup status will

change to complete, the yellow LED will still be lit. 

Pulse mode:

Only activation of the detector is being sent to the control panel

unit.

Foreign magnetic field detection:

  Once turned off, the device will 

calibrate its magnetic tamper detector. Should it detect a foreign magnetic 

field within its vicinity once its been calibrated, or a change in its own 

magnetic field is detected, the detector will indicate input activation and 

a fault. 

Note:

  When the foreign magnet detection is enabled, a window or 

a door can only be opened in the direction in which the magnet movement 

has been calibrated. Otherwise, the detector will indicate Activation and 

fault. Therefore, this function cannot be used for windows or doors that 

may be open in several ways (opening, tilting). 

On:

 Responds to a change in the contact connected to the input. 

Simple balanced input:

 

Detection  of  1  kΩ  simply  balanced  lo

op of 

external input or simple magnetic contact 

Roller blind  1, Roller blind  2

  –  roller blind modes, responds to 

repeated 

and short opening pulses with sensitivity adjustable in two stages. 

Shutter 1 = activation after 3 pulses within 2 minutes; Shutter 2 = 

activation after 5 pulses within 2 minutes. If the input loop is interrupted 

for more than 3 s, a tamper type alarm is generated. When using the INP 

- Shutter 1 and INP - Shutter 2 modes, the module is idle for 10 s after the 

activation is broadcast.

Detector testing 

Optical indication is triggered with every activation when the system is 

in service mode. Every single activation can be checked in 

F-link

, on 

the 

Diagnostics

 tab.

  

During normal operation, the optical indication is disabled. 

Battery replacement 

The system sends a report automatically when the battery is low. 

Remember to switch the system to Service mode before changing  

the batteries (otherwise a tamper alarm will be triggered). Check the right 

function of the detector after battery replacement. 

Technical specification 

Power 

1x alkaline battery type LR6 AA (1.5 V/2.4 Ah)

 

Please note: Battery is not included 

Typical lifetime of battery 

aprox. 2 years (20 activation per day) 

Low battery voltage 

<0.95 V 

Current consumption in standby mode 

74 

μ

Maximum current consumption 

80 mA 

Communication band 

 868.1 MHz, JABLOTRON protocol 

Maximum radio-frequency power (ERP) 

18.2 mW 

Communication range 

cca 300 m (open area) 

Maximum lenght of cable for external detector 

3 m 

Dimensions 

24 x 109 x 24 mm 

Dimensions of magnet 

16 x 55 x 15 mm 

Weight (w/o battery) 

35 g 

Classification 

Security grade 2/Environmental class II 

(according to EN 50131-1) 

Operational environment  

indoor general 

Operational temperature range 

-10 °C to +40 °C 

Average operating humidity 

 75% RH, non-condensing 

Certification body 

Trezor Test s.r.o. (no. 3025) 

According to  

EN 50131-1, EN 50131-2-6, EN 50131-2-8, 

EN 50131-5-3, EN 50131-6, ETSI EN 300 220-1,-2,EN 50130-4, 

EN 55032, EN 62368-1, EN IEC 63000 

Can be operated according to 

ERC REC 70-03 

Recommended screw

 

 2 x 

 

ø 3.5 x 40 mm (countersunk head)

 

JABLOTRON ALARMS a.s. hereby declares that the 

 

JA-152SHM is in compliance with the relevant European Union 

harmonisation  legislation: Directives No: 2014/53/EU, 

2014/35/EU, 2014/30/EU, 2011/65/EU, when used as intended. 

The original of the conformity assessment can be found at 

www.jablotron.com – 

the Downloads Section

 

Note:

 Disposing of this product correctly will help save valuable 

resources and prevent any potential negative effects on human 

health and the environment, which could otherwise arise from 

inappropriate waste handling. Please return the product to the 

dealer or contact your local authority for further details of your 

nearest designated collection point. 