Battery replacement can be only done by a person with 

an adequate electrotechnical qualification when 

 

the system is in service mode and when the siren  

is removed from its electrical socket. 

Before changing the battery, 

the system must be in service mode 

(see the control panel manual), then it is possible to open the siren 

cover. Use only 3.2 V, 400 mAh (BAT-3V2-CR2) battery. 
1.  Unplug the siren from the AC socket,  unscrew  the locking screws  

on the rear side of the siren (5) and open the cover. 

2.  Now it is possible to remove the old battery. Connect the new 

battery via the connector (3) to the PCB. 

Do not dispose of the used battery into the trash,  but  take  

it to a waste collection point. 

3.  Close the cover and tighten the locking screws (5). 

Notes

:  

 

If the battery is discharged (reporting low battery to the control 

panel) but the siren is powered  by the  mains power grid, it is still 

fully functional. Only in the  case of a  power outage will  the siren  

be unable to operate. 

 

It is guaranteed to recharge the battery to  80 % of its capacity  

in 12 hrs. 

Technical specifications 

Power 

230 V AC, 50 Hz; protection class II 

Supply voltage range 

90-253 V AC 

Nominal current 

4 mA 

Maximum current 

308 mA 

Backup battery / lifetime 

3.2 V, 400 mAh (BAT-3V2-CR2) / 3 years 

 

/ minimum voltage when loaded 

3.0 V 

 

/ maximum voltage when unloaded 

3.6 V 

 

/ low battery voltage 

2.6 V 

Power supply 

type A 

Communication band 

868.1 MHz, JABLOTRON protocol 

RF range 

approx. 300 m (open area) 

Backup power supply 

type Y / 24h backup 

Sounds (melodies) 

8 optional for PG output indication 

Alarm acoustic level 

105 dB / 1 m 

Dimensions (without the electric plug) 

90 x 70 x 45 mm 

Weight 

150 g 

Classification 

Grade 2 / II. indoor general 

 

(According to EN 50131-1) 

Operational environment 

indoor general 

Operational temperature range 

-10 °C to +40 °C 

Average operational humidity 

75 % RH, non-condensing 

Certification body 

Trezor Test s.r.o. (no. 3025) 

Degree of protection 

IP40 according to EN 60529 

Mechanical impact protection 

IK08 according to EN 50102 

Complies with 

EN 50131-1 ed. 2+A1+A2, EN 50131-4 

 

EN 50131-5-3+A1, EN 50131-6 ed. 2+A1, ETSI EN 300 220-1,-2 

 

EN 50130-4 ed. 2+A1, EN 55032, EN 62368-1, EN 50581 

Can be operated according to 

ERC REC 70-30 

 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-152A  

is in compliance with the relevant European Union harmonisation 

legislation: Directives No: 2014/53/EU, 2014/35/EU, 2014/30/EU, 

2011/65/EU, when used as intended. The original of the conformity 

assessment can be found at 

www.jablotron.com

 – the Downloads 

section. 

 

Note:

 Although this product does not contain any harmful materials 

we suggest you return the product to the dealer or directly  

to the producer after use. 

 

Reviews: