jablotron JA-150A II User Manual Download Page 2

The JA-150A II Internal wireless siren 

The JA-150A II Internal wireless siren 

2 / 2 

MLP20100 

Settings in accordance with security 

grade 2  

If  security grade 2 is required, it can be configured  by selecting  

EN 50131, grade. 2.

 from 

System

 

profiles

 located in the 

Parameters

 

tab  in the F-Link software.  The device will be configured according  

to the selected standard. 

Siren indication priority 

Fire alarm indication has the highest priority followed by IW and EW 

alarm.  

A lower  indication  priority belongs to interaction with the system 

(setting/unsetting…)  followed by indication upon activation of PG 

outputs  (PG1  has  a  higher priority than  PG2  etc.).  Indication with 

a higher priority always terminates indication with a lower priority. 

Priority levels of acoustic indication in descending order:  Fire alarm, 

IW/EW alarm, warning indication, unsetting the system with an active 

alarm memory indication, Setting/Unsetting, Entrance/Exit delay, alarm 

memory indication, PG output indication  and finally, the siren flashes 

an LED light when the status of the tamper sensor changes.

 

Battery replacement 

A  battery  is included,  however it is not factory-fitted in the siren 

therefore it needs to be inserted into the device. The battery recharges 

in a standard way (see 

Technical specifications

). When replacement  

is  necessary, it is possible to order the BAT-3V2-CR2 replacement 

battery. Connect it to the connector (see figure 1, point 2). The siren 

automatically detects whether the battery is connected and performs 

diagnostics. The measured values are then displayed in the F-Link 

software. The siren monitors its own battery  status and informs  

a user (alternatively the service technician) when the battery is close  

to being depleted. The device continues in its function however  

it is recommended to replace the battery within 2 weeks. Use the BAT-

3V2-CR2 type of battery specifically. 

The battery should be replaced by a service technician while 

the control panel is in Service mode. Do not discard the battery 

in the trash; dispose of it at a waste collection point. 

Siren FW update 

The siren supports wireless FW updates  performed  by the 

F-Link

 

software while the control panel is in 

Service

 mode.  

1. Click on the 

Control panel 

menu 

 

Firmware update. 

JA-150A 

will appear in a dialog window. If F-Link contains newer firmware,

it will be selected automatically.

2. Confirm the update of the selected devices by clicking on the 

OK

 

button.

3. When the FW update has finished, check the siren’s internal

settings in the 

Devices

 window 

 

Internal settings.

4. Test whether the siren functions correctly.

Dimensions 

Technical specifications 

Power supply/wattage  110 - 230 V/50 -60 Hz, 0.6 W, protection class II 

Connecting cables - maximum diameter  

1.5 mm

2

 

Backup / recharge time 

min. 24 h/max 72 h  

Battery type 

BAT-3V2-CR2/LiFePo4 

Warning: Battery is not installed 

Battery / lifetime 

3.2 V; 470 mAh/3 years 

/ minimum voltage when loaded 

3.0 V 

/ maximum voltage when unloaded 

3.6 V 

Communication band 

 868.1 MHz, JABLOTRON protocol 

Communication range 

approx. 300 m (open area) 

Classification  

security grade 2/environmental class II 

- According to 

EN 50131-1 

- Alarm sound level 

100 dB/1 m (±5 dB/1 m) 

- Back up power supply

type W/24h back up  

- Operational environment

indoor general 

- Operating temperature range 

-10 °C to +40 °C 

- Average operational humidity 

75 % RH, non-condensing 

- Certification body 

Trezor Test s.r.o. (no. 3025) 

IP rating 

IP43 according to EN 50131-1 

Dimensions 

80 x 80 x 35 mm 

Also complies with 

ETSI EN 300 220, EN 50130-4+A1:2014,  

EN 55032:2015, EN 62368-1, EN 50131-5-3, 

EN 50581:2012, EN 50131-4, EN 50131-6 

Can be operated according to 

ERC REC 70-03 

JABLOTRON ALARMS a.s. hereby declares that the JA-150A II 

is in a compliance with the relevant  European  Union 

harmonisation legislation: Directives No: 2014/53/EU, 

2014/35/EU, 2014/30/EU, 2011/65/EU.  

The original of the conformity assessment can be found  

at www.jablotron.com - Downloads Section. 

Note:

  Although this product does not contain any harmful 

materials we suggest you return the product to the dealer 

or directly to the producer after use. 

Reviews: