JA-10E BUS keypad 

JA-10E BUS keypad 

2 / 2 

MNX51101 

4. 

Button  status change on keypad

  –  The keypad indicates 

after a change of the section/PG status by a particular button 

and a section indicator.  Entrance delay and alarms  are 

indicated acoustically only.  

5.  Entrance delay/Alarms on button

 – The keypad indicates 

entrance delays and alarms with  a  function button and a 

status indicator. Change of section/PG status is not 

indicated visually or acoustically.

 

6. 

Wake-up by pressing

 –The keypad starts to optically and 

acoustically indicate after the front cover has been opened 

and also when a key or a function button has been pressed. 

RFID reader: 

In order to save energy we limit the RFID reader to 

function for 3 seconds after pressing the keypad cover. The 

reader can be also completely disabled. This setting applies to 

wireless keypads and access modules as long as  they are 

supplied permanently by  an external power supply, otherwise 

their RFID readers will always turn off automatically. 

Permanently ON

  –  the RFID reader is always active.  A BUS 

keypad ignores wake up settings. 

Activated by pressing

  –  When the keypad is activated the 

RFID wakes up for 3 seconds. 

Disabled

 – RFID is permanently disabled. 

Activated by pressing or authorization requirement

  –  

the keypad wakes up after pressing a button on a keypad cover  

or by an authorization request, for example during the  entrance 

delay. 

Unset  a  section by authorization only during an  entrance 

delay 

– using an access code or an RFID tag will unset a section 

where an entrance delay has been triggered (if the user has 

access to the section). This authorization can be used with 

wireless keypads only when they declare an entrance delay. 

WARNING

: This function is not recommended when the control 

panel is configured to use a Common section. Unwanted 

unsetting  may occur to all sections assigned to the Common 

section or it may even  occur to the whole control panel (when 

pressing the Unsetting button is followed by authorization). 

Delayed  panic

  –  this function triggers a panic alarm (silent  

or loud) with an adjustable delay during which the alarm can  

be cancelled. Activation and deactivation is done by a function 

button configured to Panic or Silent panic functions. The button 

pressed once triggers the delay. Press twice to cancel the delay. 

When authorization is enabled then it is required for activation 

and deactivation. The delay is adjustable from 1 to 255 seconds. 

Backlight intensity 

 

Indicators

 – backlight intensity of indicators 

 

Functional buttons

  –  backlight intensity  of the function 

buttons  

 

Keypad

 – backlight intensity of the keypad 

 

Display

 – backlight intensity of the LCD display 

 

Contrast

 – LCD display contrast 

Acoustic indication for sections:

  list of allowed sections for 

acoustic indication.  

 

A keypad configuration which complies with 

certification requirements must be selected 

from the list of System profiles in the 

Parameters tab of the N-Link SW. 

Optical indication 

System indicator:

 

Continuous green light 

- Normal operation. Sections controlled 

by the keypad are OK, no faults.  

Continuous yellow  light 

-  Normal operation, reported faults  

in some of the controlled sections. You can get more detailed 

information  via the LCD keypad menu after user authorization 

depending on the user access rights. 

If the optical indication is followed by a rotating Jablotron logo 

on the LCD keypad then it represents a radio communication fault 

between the control panel and the keypad  

Continuous red  light 

–  The keypad is in BOOT mode, used 

while upgrading firmware. 

Flashes green  (2Hz) 

–  Ongoing authorization during which 

the user can change the statuses of the function buttons 

or browse the keypad  menu. Authorization times  out  after  

8 seconds from the last time any of the buttons had been pressed 

or it can be cancelled by pressing ESC. 

Flashes yellow (8Hz)

 - Unsuccessful setting warning indication  

Flashes red  (8Hz)

  -  Indication of a currently triggered alarm 

in one of the sections controlled by the keypad. The type of alarm, 

name of the section where an alarm has been triggered and  

the source of the triggered alarm is visible on the LCD keypad 

Flashes  alternately  red/yellow

  -  Triggered alarm with an 

active fault 

Flashes  alternately  green/red

  –  Ongoing authorization 

with an alarm memory 

Flashes alternately green/yellow

 – Ongoing authorization with 

an active fault 

Flashes yellow 2x every 2 seconds

  -  Programming / Service 

mode. All control button indication is disabled, function keys along 

with the keypad menu are unavailable for users  and  the 

Administrator. The keypad menu is only available for a  service 

technician unless a PC is connected to the control panel.  

Flashes red 2x every 2 seconds

 - Alarm memory indication  

Flashes yellow 1x every 2 seconds

  -  Fault indication on  a 

keypad which is in sleep mode (only valid for the EN50131-1 profile) 

Flashes red 1x every 2 seconds

 - Alarm memory indication on 

a keypad  which is  in sleep mode (only  valid for the  EN50131-1 

profile) 

No indication

 – The keypad is in sleep mode. 

Function buttons and status indicators

  –  the  status of the 

function buttons is simultaneously indicated by the status 

indicators A, B, C, D 

Continuous green  light 

-  Section status is Unset or a PG 

output is OFF. 

Flashes green (4Hz)

 – Ongoing entrance delay and the system 

waits to be Unset by authorization. 

Continuous yellow  light 

-  Section status is Partially set 

Continuous red  light 

-  Section status is Set or a  PG output  

is ON  

Flashes yellow  (4Hz)

  -  System expects authorization when 

partially set or it reports a fault during partial setting. 

Flashes yellow (8Hz)

 - Unsuccessful setting warning indication. 

Flashes red (4Hz)

 – The control panel waits for authorization 

during setting or it reports a problem during setting  

Flashes red (8Hz)

  -  Alarm memory indication. It is indicated 

until it is cancelled 

No light

  -  Service mode or  a  blocked section after an  alarm 

(after blocking and cancelling alarm memory indication) 

Acoustic indication 

It can be set regardless of the keypad’s optical indication and 

sleep mode. The keypad can indicate entrance/exit delays  

or alarms. During valid authorization (by a  user code or RFID 

card), the acoustic indication of exit delays is suppressed.  

By pressing the indication button,  the  keypad  is muted 

permanently. Entrance delays and alarms are indicated until their 

times expire, unless the activation button is pressed. 

Technical specifications 

Power 

from control panel digital bus (9…15 V) 

Nominal current consumption to calculate back up 

30 mA 

Current consumption for cable selection 

110 mA 

Connection type 

data BUS – not shared 

RFID frequency 

125 kHz 

Size 

120x130x30 mm 

Weight 

217 g 

Operating temperature range 

-10 to +40 °C 

Average operational humidity 

75% RH 

Operational environment according to EN 

50131-1 II. Indoor general 

Classification  

Grade 2 (if selected in the N-Link SW) 

according to  

EN 50131-1, EN 50131-3, 

Certification body 

Trezor Test 

Also complies with  

ETSI EN 300 330, EN 50130-4, 

 

EN 50581, EN 55032, EN 62368-1, 

Can be operated according to 

ERC REC 70-03 

 

JABLOTRON ALARMS a.s. hereby declares that the JA-10E  

is in a compliance with the relevant European  Union  harmo-

nization  legislation: Directives No: 2014/53/EU, 2014/35/EU, 

2014/30/EU, 2011/65/EU. The original of the conformity assess-