INSTALLER PROGRAMMING WORK SHEET:
Press
[
∗
] [6] [Installer Code]
to enter installer programming level. The
[#]
must be pressed to exit programming level. Fill
out the following tables and use them as guide when programming.
[0] [xxxx] New Installer Code
default programmed
1010
0 _ _ _ _
[1] [xyy] Zone definition
[yy] - zone type
(alarm)
00 - Off
(none)
01 - 24Hr.
(intruder)
02 - Instant
(intruder)
03 - Delay
(intruder)
04 - Next delay
(intruder)
05 - 24Hr. silent
(panic)
06 - Instant silent
(panic)
07 - Delay silent
(panic)
08 - Interior instant
(intruder)
09 - Next delay interior (intruder)
10 - Fire
(fire)
11 - 24Hr. delay silent (panic)
12 - Warning 24Hr.
(warning)
13 - Warning instant
(warning)
Note: loop 6 can work as arming control
[411]
zone
[x]
default
programmed
enter [yy]
1
delay
1 1 _ _
2
next del. in.
1 2 _ _
3
interior inst.
1 3 _ _
4
instant
1 4 _ _
5
instant
1 5 _ _
6
instant
1 6 _ _
[2] [xms] System Times
[m] =
minutes (from 0 to 9)
[s] =
x10 seconds (from 0 to 5)
examples:
[ms] = 32 = 3min. and 20sec.
[ms] = 04 = 40sec.
Note: if [ms] = 00 = 5sec
[x] time
default
programmed
enter [ms]
0
entry
20 sec.
2 0 _ _
1
exit
40 sec.
2 1 _ _
2
alarm
3 min.
2 2 _ _
[y] Ext. Siren Relay Int. Siren
0 OFF OFF OFF
1 ON OFF OFF
2 OFF ON OFF
3 ON ON OFF
4 OFF OFF ON
5 ON OFF ON
6 OFF ON ON
7 ON ON ON
For Panic alarm [y] can only be 0 or 2
Panic alarm always activates Panic o.
Fire alarm aiways activates Fire out.
ES
= Ext. Siren;
IS
= Int. Siren
[3] [xy] Alarm outputs definition
[x]
alarm
default otputs
programmed
enter [y]
0
technic.
Relay
3 0 _
1
fire
ES, IS, Relay, Fire
3 1 _
2
intruder
ES, IS, Relay
3 2 _
3
panic
Panic
3 3 _
[4] [xy] System option functions
Chirp sounds:
0=buzzer only, 1=IS,
2=ES, 3=IS & ES
L6 arm control:
0=OFF (L6 = zone)
1=ON (L6=arming)
Attempts number:
can be from 0 to 9
0=without any limit
Quick arming:
0=disabled, 1=enabled
Auto At Home:
0=disabled, 1=enabled
Silent if. sb in: 0=adible (IS &rel. can work)
1=silent (IS & rel.disabled)
Examples:
401 = Chirp Sounds by Internal siren
411 = L6 works as external arming input
431 = Quick arming enabled
[x]
function
default programmed
enter [y]
0
chirp sounds
buzzer only
4 0 _
1
L6 arm control
OFF
4 1 _
2
attempts no.
5
4 2 _
3
quick arming
OFF
4 3 _
4
auto AT HOME
OFF
4 4 _
5
silent if sb. in
OFF
4 5 _
[5] [xy] Testing of outputs
If you also install a device with
optional outputs use [51y]
commands for their testing. See the
manual you got with the optional
device.
To activate
enter
Relay
5 0 0
Ext. Siren
5 0 1
Panic
5 0 2
Fire
5 0 3
Arm
5 0 4
Int. Siren
5 0 5
press
∗
to switch the output off
H-915 installation manual
11/10