jablotron HESTIA-915 Installation Manual Download Page 1

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Security Alarm Control Panel 

HESTIA-915 

 

installation manual 

 

Summary of Contents for HESTIA-915

Page 1: ...Security Alarm Control Panel HESTIA 915 installation manual...

Page 2: ...ired 12V from 1 2Ah to 40Ah stand by consumption 25mA back up power output 12V max 500mA inputs eight loops FIRE TAMPER and 6 fully programmable loops type of loops balanced with End Of Line resistor...

Page 3: ...put is also triggered if normally closed contacts wired in series with EOL resistor are opened see the wiring diagram The Fire alarm is activated if a detector connected to a FIRE input is triggered T...

Page 4: ...5 can be used connect all of them in parallel Check carefully that you have connected corresponding wires before you turn on the power to the control panel The built in keypad on the H 915C model is c...

Page 5: ...n was enabled in the installer programming level If quick arming is enabled the H 915 can be AT HOME armed by entering only the 9 command DISARMING Enter a valid access code to disarm If the chime jum...

Page 6: ...tically in the moment when used once for arming NOTE If you press 9 in user programming level the H 915 control panel will send information about events history to the special serial interface printer...

Page 7: ...f the premises is entered without coming through a delay entrance and a next delay loop is triggered an immediate intruder alarm will be generated 05 24Hr silent loop operates as the type 01 but it tr...

Page 8: ...med by both sirens The y can only be from 0 to 3 4 1y External arming control with loop 6 input If y 0 zone input 6 will work as programmed in section 1 If y 1 than zone input works as input for exter...

Page 9: ...will start in the alarm condition when the power is switch on again If there is any reason to switch the power completely off for example when you want to extend the system with an optional device we...

Page 10: ...3 ON ON OFF 4 OFF OFF ON 5 ON OFF ON 6 OFF ON ON 7 ON ON ON For Panic alarm y can only be 0 or 2 Panic alarm always activates Panic o Fire alarm aiways activates Fire out ES Ext Siren IS Int Siren 3...

Page 11: ...USER S OPERATION GUIDE OF H 915 Zone location No protected area zone type 1 2 3 4 5 6 Tamper Fire Exit Entry Alarm if troubles call your installer phone H 915 installation manual 11 11 TBT502 01...

Page 12: ...H 915 installation manual 11 12 TBT502 01...