The GD-04K universal GSM  

communicator and controller 

The GD-04K is a universal GSM communicator. It controls and / or reports status of 

different appliances remotely. Control can be performed by SMS instructions or dialling in. 
The module is equipped with 2 power outputs with a status or pulse reaction. For status 
monitoring the GD-04K module has four input terminals which react to grounding 
(connecting to the GND terminal). Activation / deactivation of an input terminal can be 
reported as an SMS, dialling in or a combination of both these options to up to 100 
authorised telephone numbers. The GD-04K can also be supplemented by a GD-04A 
backup battery which ensures powering the module when the mains is disconnected. The 
module allows configuration using a PC with installed 

GD-Link 2.0.0

 software (or higher) 

locally via the USB cable or remotely. It can also be configured by programming SMS. 

1.  Using the GD-04K 

The GD-04K module uses four inputs (A – D) for SMS reporting (optionally dialling) to 

predefined telephone numbers. It also offers 2 power relay outputs with options to control 
them by pre-defined SMS commands or by dialling in according to the settings from 
authorised numbers or from any (non-authorised) numbers. 

Relay control:   

 

by SMS instructions

 which can be independently pre-set for switching ON / OFF of 

each relay output. Both relays can work in 

status

 or 

pulse mode

, the mode is selectable 

in the settings. If 

pulse mode

 is selected then based on activation command the output 

will be switched for interval between 1 s to 10 hrs. 

 

Dialling in.

 Both relays (X and Y) can be controlled by dialling in from a known 

telephone number. Up to 100 numbers can be stored in the communicator. The GD-
04K doesn´t pick up an incoming call but verifies the caller’s telephone number. If the 
caller’s telephone number is authorised, the call is rejected and the relay is activated / 
deactivated as required (when the Impulse reaction is set then for predefined time). 

 

Dialling in with limited use

. While entering authorised telephone numbers the limit of 

their use can also be defined for each of them. When the usage limit of a pre-defined 
number is reached then any other calls are ignored. Reactivation can only be allowed 
by an administrator (by SMS). This function is suitable as a subscription for entrance to 
garages and so on. 

Input status reporting: 

 

Sending an SMS report

 when some of the inputs (A – D) are activated / deactivated 

(connected or disconnected to / from GND). Each input has an option to edit the texts 
which are reported. An SMS can be sent to all telephone numbers stored in the 
communicator. For higher alert notice SMS report can also be followed by calling to the 
numbers to which SMS reports have been sent. 

 

Status monitoring

. By the SMS command “STATUS”, the status of all inputs and 

outputs can be checked when needed. This way is for example possible to check status 
of connected devices which each status change is not required to report. 

Caution:

 The GD-04K is not meant and is not certified as a security device to protect 

premises.

 

Summary of Contents for GD-04K

Page 1: ...settings If pulse mode is selected then based on activation command the output will be switched for interval between 1 s to 10 hrs Dialling in Both relays X and Y can be controlled by dialling in fro...

Page 2: ...Output relay fuses 9 Input output and power terminals Terminal descriptions Low voltage terminals 12 V Terminal for 12 V DC connection from included adapter or another external power supply which pro...

Page 3: ...re galvanically separated from the communicator circuits complying with 4kV safety isolation requirements 3 Installation and initial setup 1 Select an appropriate place for communicator installation c...

Page 4: ...backup battery is charged 5 Initial powering up 1 Turn the power on the red LED starts flashing to indicate logging of the module on to the GSM network if it doesn t check the power supply proper con...

Page 5: ...r events see Optional functions To erase the service number enter STN iGQp GD 04K 5 MNY51104 3 Send the SMS command STATUS from your cell phone to the SIM card inserted into the GSM communicator 4 The...

Page 6: ...llows all parameters to be set as if you are connected locally using a USB cable Figure 3 GD 04K 11 MNY51104 11 Table 1 SMS programming instructions overview A programming SMS always has to begin with...

Page 7: ...ngs in your computer for future use Save When the communicator receives new setting then a factory RESET is performed and the setting is uploaded All programming options which are not filled in will b...

Page 8: ...When a pre set limit has been reached the telephone number can not be used to control more Control by dialling in can only be realized by phone numbers with enabled caller ID visibility telephone numb...

Reviews: