jablotron DAVID GD-04 User Manual Download Page 15

 

 
 
 
 
 
 

Summary of Contents for DAVID GD-04

Page 1: ...k We hope that the skills of your tiny David will help you manage the giant 1 Basic description SIM Bus connector Battery connection LED indicator RESET jumper GSM antenna Tabs SIM card Output fuses 1 1 David provides 2 output contacts of power relays X and Y each allows up to 5A 250V 4 input terminals A to D for SMS reporting the inputs react to a connection or disconnection to or from a common G...

Page 2: ...ntering numeric codes DTMF codes on the telephone keypad during calls see 11 2 A GD 04P link cable which allows you to connect David to a PC through a USB port and perform any desired configuration using GDLink software A GD 04R radio module which allows input A to D activations via wireless buttons or detectors of the OASiS series and also provides David with the capability of output relay X or Y...

Page 3: ...k is indicated by the LED flashing if no indication occurs check the power supply wiring 5 After GSM registration the LED stops flashing usually within 1 minute Continued flashing indicates a GSM registration fault Disconnect the power supply and check that a valid SIM card has been correctly installed into the device see 2 and 3 6 Send the SMS instruction STATUS to David s SIM card number 7 David...

Page 4: ... The programming instruction format is explained in the following example PC ARX heating on DRX heating off where PC is the access programming code required at the start of any programming SMS message 2 to 8 ASCII characters the factory default setting is PC is a comma separator ARX is the name of the instruction for programming the text you wish to use for switching relay X on via SMS The desired...

Page 5: ...e operation via dialling in David allows you to control the X and Y relays via dialling in from pre authorised phones If a call is made to David from a pre programmed number the call is rejected and the relay reacts as follows o If a limit is set to the relay switch on period then the relay switches on for the limit period o If no limit is set zero value is set for the limit then the relay switche...

Page 6: ...5s Note Performing a RESET erases all programmed tel numbers and texts 11 Optional accessories David s functionality can be extended by optional modules or other separately supplied accessories 11 1 The GD 04A back up module This module is imbedded in a specially enlarged replacement cover Installation is performed by replacing the original cover together with wiring the GD 04A module to the GD 04...

Page 7: ...shes a connection so that the receiver s relay status mirrors David s relay status There is no limit to the number of UC AC receivers which can be connected this way 11 3 2 Wireless device input assignment and operation Each input A to D can have one OASiS wireless device assigned to it This way triggering an external wireless device has the same effect as GD 04 input activation by physical connec...

Page 8: ...sly enrolled devices Thus all the desired devices should be enrolled in a single enrollment session 4 Exit enrollment mode by pressing the XY button enrollment is automatically terminated after the fourth device has been assigned or after 40 seconds 5 After enrollment mode termination the LED on the module lights for approx 5 seconds to indicate enrollment data storage 6 It is possible to enroll a...

Page 9: ...ad GDLink from www jablotron cz 11 4 5 Installing GDLink and the drivers 1 Connect the GD 04P cable to a free USB port on your PC and insert the CD into the CD drive 2 Wait for New Hardware Wizard to start up 3 Search for the drivers on the removable medium CD 4 When installing for WIN XP ignore the notification about wrong authenticity with WIN XP and continue with the installation process Leave ...

Page 10: ...05 14 Safety EN 60950 1 EMC EN 301489 7 EN 55022 and EN 50130 4 Radio transmissions ETSI EN 301419 1 and EN 301511 Environment II indoor general 10 C to 40 C Dimensions without antenna 76 x 110 x 33 mm GSM antenna connected to SMA connector Jablotron Ltd hereby declares that this product is in compliance with the essential requirements and other relevant provisions of Directive 1999 5 EC The origi...

Page 11: ...ion SMS when activated SMS when deactivated Input A Phone numbers SMS when activated SMS when deactivated Input B Phone numbers SMS when activated SMS when deactivated Input C Phone numbers SMS when activated SMS when deactivated Input D Phone numbers ON command SMS DTMF code OFF command SMS DTMF code Relay X Tel numbers authorized for relay control ON command SMS DTMF code OFF command SMS DTMF co...

Page 12: ...n x x n Use LDY for relay Y x x tel number The numbers are added to the list of authorised numbers up to 50 in total n limit in the number of calls 1 to 99 exceeding the limit removes the number from the list this is reported to the service number by SMS Example LDX 777123457 31 authorises a new number for relay X control for a maximum of 31 calls empty list Erasing tel numbers authorised for rela...

Page 13: ...DTMF code to switch relay ON2 CAX xx x Use CAY for relay Y xx x numeric code up to 8 digits Example CAY 1234 Instruction CAY erases the code none DTMF code to switch relay OFF 2 CDX xx x Use CDY for relay Y xx x numeric code up to 8 digits Example CDY 1234 Instruction CDY erases the code none Wireless device assignments3 LRN n xx x n x n A B C D X or Y input or output the device should be assigned...

Page 14: ......

Page 15: ......