The AC-83 wireless output relay module 

2 / 2 

MJT51403 

 

 

 

 

Primary device  Control device 

Enrollment 

method 

Notes 

Thermostat 

Control panel PG 

output 

Enter 299 in 

Service mode 

  Allows for heating mode switching (temperature regulation/antifreeze). 

  Not recommended for use in combination with other remote controls.  

Remote control 

Press any button 

  Allows for heating mode switching (temperature regulation/antifreeze) via a remote control.  

Magnetic door-

detector 

Connect the battery 

  When triggered (a door/window is opened), the heating mode switches to antifreeze.  

 

 

 

 

  Wireless devices enrolled together with a thermostat to a single 

relay can be used to determine how that relay reacts to signals from 

the wireless thermostat. If desired, the relay can react only to the 

freezing protection signal from the thermostat to turn on the heating 

when the temperature gets below about +6C, or alternatively it can 

react to the thermostat signal which demands heating when the 

room temperature is lower than that pre-programmed in the 

thermostat. The relay can be switched between these two modes 

by operating the wireless devices. 

  The thermostat repeats its signal every 9 minutes, so 

if the AC-83 

power is turned off for a while, and then on again, the relay will 

synchronize with the thermostat within 9 minutes

.

 

 Use with a JA-8x OASiS control panel 

Using an OASiS control panel with a thermostat in a combination is 

only possible with the thermostat enrolled before the control panel. PG 

outputs should be programmed in the control panel to have an 

ON/OFF function. The PGX output can only be enrolled to the X relay, 

and PGY to the Y relay. 

  If the 

control panel is enrolled to the X 

relay (by entering 299) 

then the X relay is switched on whenever the corresponding 

thermostat is activated and the control panel’s PGX output is active. 

  If the 

control panel is enrolled to the Y 

relay (by entering 299) 

then the Y relay is switched on whenever the corresponding 

thermostat is activated and the control panel’s PGY output is active. 

  Only 

one control panel PG output 

can be enrolled to each relay. 

 

The 

control panel PG output 

allows the switch between temperature 

regulation/antifreeze modes to be controlled either by the system 

keypad 

or 

remotely via a mobile phone or the Internet

 

Avoid enrolling key fobs to the same relay to which thermostat(s) and 

PG outputs are enrolled as the control panel repeats currently valid PG 

signals every 9 minutes. (The signals from the control panel would 

override signals from the controller.) 

 

Though the control panel’s requests to switch the heating mode 

are recognized instantly, the relay will not react until a 

subsequent thermostat signal is received (within 9 minutes). 

 Use with JA-80M (JA-82M) magnetic door-detectors   

Heating mode switchover by thermostat can be overridden by a 

JA-80M or JA-82M magnetic door-detector signal (or also signals from 

a JA-80D universal transmitter). If such a detector is used, then 

triggering the detector switches the heating to 

antifreeze mode

, and 

de-triggering the detector switches to 

regulation mode 

(regulating the 

heating to a pre-programmed temperature). 

Though the JA-80M/JA-82M requests to switch the heating mode are 

recognized instantly, the relay will not react until a subsequent 

thermostat signal is received (within 9 minutes). 

When used in combination with an OASiS control panel, magnetic 

door-detector activation status is of higher priority: At least one of the 

detectors being triggered enforces antifreeze mode regardless of PG 

output signals. 

Magnetic door-detectors cannot be used in combination with remote 

controls. 

 Use with RC-8x remote controls 

You can switch heating modes via a remote control. Pressing the 

 

(or 

)  button switches the relay to 

regulating the heating to the 

(comfortable)

  pre-programmed temperature

, pressing    (or 

switches the  relay to 

regulating the heating to the anti-freeze 

temperature

 

Though the RC-8x requests to switch the heating mode are 

recognized instantly, the relay will not react until a subsequent 

thermostat signal is received (within 9 minutes). 

Using remote controls for switching between heating modes 

cannot be combined with control panel use or with magnetic-door 

detectors

 Resetting the AC-83 unit 

As a factory default, the AC-83 is supplied with nothing enrolled. To 

reset a particular relay, do the following:  

  Repeatedly press the X button (or the Y button for the Y relay) to 

achieve several LED flashes. 

  Then, continuously press the same button and keep pressing it (for 

approx. 4 seconds) until all the LEDs flash a couple of times (= 

reset). Then release the button. 

 Technical specification 

Power supply 

230V/50Hz, class protection II 

Consumption  

about 1W 

Relay contact rating 

 

resistive load 

max. 2,5A / 250V AC 

inductive (capacitive), lamp load 

max. 0,5A / 250V AC 

Required fuse rating 

max. 5A 

Communication band 

868 MHz, Oasis protocol 

Device enrollment is stored in non-volatile memory –  

  

unaffected by power disconnection 

Minimum distance from transmitting devices 

1 meter 

Operating environment 

general, indoor –10 to +40 °C 

Enclosure 

IP40  EN 60529 

Mechanical immunity 

IK08  EN 50102 

Can be operated according to 

 ERC REC 70-03 

Complies with  

ETSI EN 300220, EN  50130-4, EN 55022,  

EN 60950-1 

 

 

 

 

 

 

 

JABLOTRON ALARMS a.s. hereby declares that the AC-83   

is in a compliance with the relevant Union harmonisation 

legislation: Directives No:  2014/53/EU, 2014/35/EU, 

2014/30/EU, 2011/65/EU. The original of the conformity 

assessment can be found at 

www.jablotron.com

  -  Section 

Downloads. 

 