The diagram below shows the wiring schematic for the DM-1A.  If using a male “XLR” type connector, 
the GND(shield) should be connected to pin 1, the red(MIC+) connected to pin 2 and the black(MIC-) 
connected to pin 3.  When using an amplifier 
that has VOX muting (such as a Davis ampli-
fier), the yellow(mute) and orange(mute) wires 
should be cut or taped. 

When using an amplifier without VOX muting, 
the yellow and orange wires should be con-
nected to the “mute” terminal strip on the back 
of the amplifier. 

Option:  

You may order a “XLR” type connector prewired to the DM-1A cable for an additional 

charge.  Call Customer Service for information regarding the specific connector desired and the 
nominal prewiring cost. 

NEW TECHNOLOGY

OLD RELIABILITY

J.W. Davis & Company

3030 Canton Street • P.O. Box 710219 • Dallas, Texas 75371-0219

Sales 800-527-5705 • Sales Fax 800-388-9106 • Corp 214-651-7341 • Corp Fax 214-939-0328 • www.jwd.com • [email protected]

The Mark of the professional... 

Net Weight 

Impedance 
Sensitivity 
Switches 

Color/Finish 
Construction 

Dimensions 

Connector 

600 ohms 
- 72 dB (ref 0 dB = 1V/ mBar) 
Push-To-Talk 
Lock-On 
Matt Black 
Base – Zinc die-casted 
Base Cover – ABS plastic 
1.09 lbs. (0.49 grams) 
5.63"D x 3.47"W x 13"H 
(143 mm x 88 mm x 329 mm) 

9.8 ft. (3 m), 4 Conductor 
Shielded Cable 

Polar Pattern 

Cardioid polar response with 
noise canceling 

Frequency Response 

100 to 12,000 Hz 

Element Type 

Dynamic 

Specifications

 

20 

-50 

-60 

-70 

-80 

-90 

-100 

200 

2k 

20k 

dB 

Hz 

Frequency Response 

Magn dB re (0dB = 1V/

µ

Bar) 

The dynamic desktop microphone shall be a J.W. Davis DM-1A or equivalent having a cardioid polar response pattern with noise 
canceling and a frequency response of 100 Hz to 12,000 Hz.  The impedance of the unit shall be 600 ohms with a sensitivity of - 
72 dB (ref dB = 1V/ mBar).  The design shall include a 9.8 foot cable with four conductors with a two conductor shielded balanced 
line output and a separate pair of conductors for connection to a contact closure muting input.   The unit shall have a nine inch 
flexible gooseneck and a push-to-talk switch with a separate lock-on switch mounted in the base.  The base construction shall be 
zinc die-casted with a ABS plastic cover.  The unit shall have a black matte finish with dimensions 5.63”(L) x 3.47”(W) x 13”(H) and 
a weight of 1.09 pounds. 

ARCHITECT’S AND ENGINEER’S SPECIFICATIONS

 

INSTALLATION INSTRUCTIONS

 

Polar Pattern 

(1k Hz, 5k Hz, 10k Hz) 

.................... 

.................... 

......... 

........................ 

......................... 

.......................... 
.......................... 

...................... 

...................... 
...................... 

....................... 

....................... 

......................... 