21
9. RS232 Command Control
Default IP Address
192.168.1.168
TCP Port
5000
UDP Port
5001
Telnet Port
23
Baud Rate
115200
Control software operation:
The serial control software is illustrated with SSCOM32 as an example.
Basic Settings:
Double-click the software in the installation package to run specifically and install the RS232
software on the computer.
Enter the main interface of the software.
In the parameter config. area, select the serial port number that the serial line connects to the
PC
Baud rate: 115200 (default)
Data location: 8.
Stop bit: 1
Check bit: no
You can input commands in the command input area to control the local or remote receiver,
such as changing IP address to be 192.168.1.168:
Command is: #network ip=192.168.1.168