J-TEC HBM453 Operator'S Manual Download Page 2

MAN0063

Mechanical Installation

The J-TEC HBM453 has two pieces, the Handheld Display and the Flow Meter.  

To operate, attach the cable from the Handheld Display to the Flow Meter (the cable must be con-

nected in order for the system to function).  

A typical connection to the Flow Meter is made by placing 

flexible

 hose onto the outside of the inlet 

tube and outlet tube.  The labeling of the 

flow

 direction on the Flow Meter must be aligned with the 

flow

 in the tube.  The Flow Meter should be installed with a minimum of 12 inches of straight tube 

upstream.  This condition provides a more symmetrical 

flow

 

profile,

 which is necessary to obtain 

accurate and repeatable results.

If liquids are present in the gas 

flow

 stream, the Flow Meter should be installed so that liquids will 

not collect on the ultrasonic transducers in the tube.  Installing the Flow Meter vertical with 

flow

 into 

the top and out the bottom will encourage liquids to drain out of the Flow Meter.

The Flow Meter and interconnecting cable should be positioned at least 12 inches away from any 

ignition wires or fuel injector component to avoid noise interference.

Operation

With the cable attached from the Handheld Display to the Flow Meter, turn on power by cycling the 

switch to the “1” position (the “0” position on the power switch is OFF).

The display on the Handheld will show “J-TEC HBM453” 

briefly

 then display 0.0 and Acfm (actual 

cubic feet per minute), if there is no 

flow

 through the Flow Meter.  

Install the Flow Meter, with at least 12 inches of upstream tubing, onto the desired device to measure 

flo

w.  Ensure the arrow on the Flow Meter is aligned with the direction of the 

flow

 stream.

Power remains on until the power switch is cycled to the OFF position (“0” on the switch).

Cleaning and Maintenance

The inside of the 

flow

 tube and strut must be kept clean.  If the meter produces erratic readings a 

cleaning schedule should be implemented.  To clean the 

flow

 tube and strut, gently brush the inside 

of the tube with a soft brush or cotton swab.  A solution of a mild detergent and water may be used 

to loosen deposits.  Ensure detergent is rinsed away and the inside of the 

flow

 tube is dry before 

use.

DO NOT use wire brushes or high-pressure liquids.  These may cause damage to the transduc-

ers.

Troubleshooting

No Display:  Are batteries installed correctly and fully seated? 

 

Are batteries fresh or completely recharged?

 

Is the Flow Meter connected to the Handheld Display?

Erratic readings:  Ensure there is no blockage in Flow Meter 

flow

 tube.

 

Ensure there is not 

excessive

 condensate in 

flow

 tube.

 

Ensure Flow Meter and/or cable is at least 12 inches away 

 

 from any ignition wiring or other electrical wiring.