background image

Operator's Manual 

for the 

HBM453 DISPLAY & BLOW-BY METER SYSTEM

Visit us online: j-tecautomotive.com

5005 Blairs Forest Lane NE, Suite L  •  Cedar Rapids, IA 52402

phone 319-393-5200  •  fax 319-393-5211

[email protected]

SPECIFICATIONS

Measured:

 

Air or low pressure gas*

Flow rate measured:

 

0.8 to 16.0 ACFM (Actual Cubic Feet per Minute)

Operating (GAS) temperature:   0º to 200ºF

Operating pressure:

 

-5 TO +5 PSIG

Accuracy:  

 

± 3% full scale

Repeatability:

 

± 1.0% of reading

Line Size:

 

5/8” ID 

Construction:

 

Ryton® (PPS) and ABS plastic

Interface Cable Length:

 

6 feet

Ambient temperature limits:

 

-20º to 150ºF

Response Time:

 

100 milliseconds

Power Source:

 

4 AA batteries (use alkaline or NiMH rechargeable)

 

Operation time is approximately 40 hours 

 

  on fresh or fully charged batteries

Display:

 

8 characters x 2 lines: Viewing area 1.5” x 0.6”

 

Top

 

line

 

is

 

the

 

flow

 

Bottom line is the engineering units (ACFM).

*(not approved for explosive gas mixtures, except for crankcase vapors)

J-TEC 

flow

 meters operate on the principle of vortex shedding.  

A small strut inside the 

flow

 tube creates a Karman vortex street 

and the vortex formation is sensed by means of an ultrasonic 

beam directed across the tube.  The 

flow

 meter electronics uses 

the vortex frequency to determine the 

flow

 rate.  

The J-TEC HBM453 is a two piece design, consisting of a 

handheld enclosure with a display, battery power compartment, 

interface cable and a separate 

flow

 measurement body.

J-TEC 

flow

 meters have a 12-month warranty period.

Reviews: