background image

J.P.  SELECTA s.a.

Ctra. NII Km 585.1 Abrera  08630  (Barcelona) España

Tel (34) 93 770 08 77   Fax (34) 93 770 23 62

e-mail[email protected] - http://www.jpselecta.es

 GUIDE DE L’UTILISATEUR

CODE 80037.02

REV 0 28/09/09

(Sous  réserve  de  modification)

Pag.: 12

PROGRAMME  DE  FABRICATION  /  MANUFACTURING  PROGRAMME

    - Agitateurs magnétiques / 

Magnetic stirrers.

- Agitateurs orbitaux, rotatifs et va-et-vient. / 

Orbital, rotary and vibratory stirrers.

- Appareils pour anatomie et histologie. / 

Clinical and biotechnological instruments.

- Appareils à basse température. / 

Low temperature apparatus.

- Appareils de régulation et de contrôle. / 

Regulation and control.

- Bacs conservateurs. / 

Chest freezers.

- Armoires réfrigérées pour banques de sang. / 

Blood bank storage cabinet.

- Enceintes pour germination des plantes. / 

Plant germination incubator.

- Autoclaves pour stérilisation. / 

Autoclaves.

- Bains de nettoyage aux ultrasons. / 

Ultrasonic cleaners.

- Bains thermostatiques. / 

Thermostatic baths

- Battteries de kjeldahl et batterires de soxhlet. / 

Kjeldahl battery and Soxhlet battery.

- Centrífugeuses de paillasse et centrifugeuses réfrigérées. / 

Centrifuges.

- Etuves à bactériologie et cultures. / 

Bacteriological and culture ovens.

- Etuves pour dessiccation sous vide.. /

- Etuves pour dessiccation et stérilisation. / 

Drying and sterilization ovens.

- Etuves pour dessissation et stérilisation  à circulation forcée de l’air. / 

Drying and sterilizing ovens by fan

convection.

- Extracteur pour la détermination de la cellulose et des fibres. / 

Extractor for Determination of Cellulose

and Fibre.

- Extracteur pour le détermination des graisses. / 

Extractor for the Determination of Fats in Food and Oils.

- Fours à moufle jusqu’à 1.150°C. / 

Muffle furnaces up to 1,150ºC.

-  Instruments  en  acier  inoxydable,  nickel  et  zirconium.  / 

Instrumental  in  stainless  steel,  nickel  and

zirconium..

- Manteaux chauffants / 

Heating mantles.

- Plaques chauffantes. / 

Hotplates.

- Thermostats à immersion./ 

Immersion thermostats.

- Thermostats à blocs métalliques pour tubes et digesteurs kjeldahl. / 

Metallic block thermostats.

- Ultrathermostats de circulación. / 

Circulation ultrathermostat.

- Unité de distillation pour protéines. / 

Distiller for proteins.

- Viscosimètres. / 

Viscometers.

Summary of Contents for PRECISDIG 6001195

Page 1: ...Fax 34 93 770 23 62 e mail selecta jpselecta es http www jpselecta es PRECISDIG 6001195 PRECISDIG 6001236 PRECISDIG 6001196 PRECISDIG 6001237 PRECISDIG 6001197 PRECISDIG 6001238 PRECISDIG 6001198 PREC...

Page 2: ...LAGE PACKING LISTS 3 ACCESSOIRES ACCESSORIES 3 SPECIFICATIONSTECHNIQUES TECHNICAL FEATURES 4 DESCRIPTION DE L APPAREIL EQUIPMENT DESCRIPTION 5 INSTALLATION INSTALLATION 5 MODE OPERAT0IRE OPERATION 6 S...

Page 3: ...r C o v e r w ith h o le s a n d re du cin g dis cs 1 0 5 8 0 6 0 a n d 3 7 m m in s ta in le s s s te e l C o u v e rc le fo rm e to it G a b le co v e r P la q u e d e fo n d P e rfo ra te d s h e...

Page 4: ...id until the level covers at least the heater element The liquid or mixture to be employed must be adequated to the model of bath and the working temperature Temp rature jusqu 100 C Temperature up to...

Page 5: ...ed If you have to change the plug bear in mind the following Blue cable Neutral Brown cable Phase Yellow green cable Earth INSTALLATION Place the bath on a flat horizontal and level surface Bear in mi...

Page 6: ...6 11 12 5 Indicateur d tat de marche 6 Indicateur de temps d attente 7 Touche s lecteur de temp rature Consigne temp raturedepuisl ambiance 5 C jusqu 100 C 200 C selon mod le 8 Touche s lecteur du tem...

Page 7: ...op ration l indicateur 2 s illumine En actionnant le poussoir 8 deux fois et le 9 ou 10 pour pr fixer le tempsd attente avant la mise en marche Pendant cette op ration l indicateur 6 s illumine En act...

Page 8: ...e until it clicks and the red indicator lamp 15 lights up 5 Wait until the bath cools to reset the safety ther mostat with 6 button 6 Select the working temperature of the bath with temperature select...

Page 9: ...P SELECTA S A annule automatiquement la garantie GUARANTEE This product is guaranteed for one year The guarantee does not cover damage caused by incorrect use of causes beyond the control of J P SELEC...

Page 10: ...Tel 34 93 770 08 77 Fax 34 93 770 23 62 e mail selecta jpselecta es http www jpselecta es GUIDEDE L UTILISATEUR CODE 80037 02 REV 0 28 09 09 Sous r serve de modification Pag 10 SCHEMA ELECTRIQUE ELEC...

Page 11: ...ELONA SPAIN d clare que les quipements Declares that the equipment Mod les Model Code Code PRECISDIG 6001195 PRECISDIG 6001196 PRECISDIG 6001197 PRECISDIG 6001198 PRECISDIG 6001236 PRECISDIG 6001237 P...

Page 12: ...erires de soxhlet Kjeldahl battery and Soxhlet battery Centr fugeuses de paillasse et centrifugeuses r frig r es Centrifuges Etuves bact riologie et cultures Bacteriological and culture ovens Etuves p...

Reviews: