sonicom™
J D UltraSonics
ULTRASONIC NOZZLES & AIR ATOMISERS
DUST SUPPRESSION - HUMIDIFICATION - ATOMISING - FOGGING
ATLAS ULTRA VIOLETDISINFECTION UNIT
OPERATING AND MAINTENANCE
Page 1: ...sonicom J D UltraSonics ULTRASONIC NOZZLES AIR ATOMISERS DUST SUPPRESSION HUMIDIFICATION ATOMISING FOGGING ATLAS ULTRA VIOLET DISINFECTION UNIT OPERATING AND MAINTENANCE ...
Page 2: ...low protected with a fly screen Water by law 30 Tanks should only hold sufficient water for a few hours use LAMP LIFE The lamp will continue to emit sufficient ultra violet for efficient operation of the unit for a period of 4 000 hours The lamp must always be replaced at this interval although a safer recommendation usage period is one year or 2 000 hours Failure to change the lamp will result in...
Page 3: ...nd on the top end of the lamp Fit the new lamp into the connector by holding the ceramic end and noting the keyed format which ensures correct connection www jdultrasonics co uk 44 0 1924 378 448 UV DISINFECTION OPERATING MAINTENANCE OPERATING AND MAINTENANCE INSTRUCTIONS Caution Prior to performing any work on the disinfection system always disconnect the power supply first To replace the lamp it...
Page 4: ...hanging the lamp on the system the controller must be reset in order for the system to begin its countdown function on a newly installed lamp To perform this reset firmly depress the button on the front of the controller and then manually power up the unit Keep holding down the button for five seconds until the controller has reset the internal timer Release the button and the lamp countdown featu...