22
November 5, 2015
Vertical Installation
The
ROBY2500/ROBY2500 CUISINIERE
must be installed in
accordance with the applicable local laws or the CAN/CSA-
B365, NFPA 211 (USA). Follow the chimney manufacturer’s
instructions to install the chimney.
Combustion air intake
In conventional designed homes, natural ventilation is enough
to operate the wood stove efficiently.
In mobile homes and Novoclimat homes, stoves might not work
properly. When some appliances are in motion, such as tumble
dryer, kitchen hood or bathroom fan, the smoke might come in
the house because of the depressurization which they would
cause. In this case, you must install a combustion air intake
system.
A mobile home built on a foundation is considered as a
conventional house.
Air Inlet Obstruction
If the stove extinguishes after closing the door, it’s possible that
the air inlet is obstructed by something.
After a long unused period, insects or animals can build a nest
inside the air inlet. In winter, snow can accumulate over the air
inlet and obstruct it especially after a storm.
Before warming season, always inspect air inlet pipe to make
sure nothing obstructs the outside air inlet.