eControls
iWD3P V102
eControls
iWD3P V102
Vacation Off
Mode Y/NEXT/SAVE
Vacation On
Mode N/NEXT/SAVE
Vacation On
Mode N/NEXT
Vacation Off
Mode Y/NEXT
Vacation Off
Mode Y/NEXT
Manufacturer
Info Y/NEXT
Contractor
Info Y/NEXT
Display Error
Message Y/NEXT
Display Status
Y/NEXT
eControls, Inc.
949 916 0945 NXT
Best AC
555 111 2222 NXT
No Error
Message NEXT
SA Sensor Short
NEXT
MENU
MENU
Y
N
NEXT
Y
Y
Y
Y
NEXT
NEXT
NEXT
Turning Vacation Mode On Using the PDM
Turning Vacation Mode On Using the SW01
Model SW01
If Vacation Mode is On
Display Manufacturer Info
Display Contractor Info
Display Error Message
Display Status
Press the Menu key and the Vacation
screen is shown. Press the Yes key to turn
the Vacation mode on or press No to turn
the Vacation mode off. Press SAVE to
store your selection.
Set the switch to vacant at the end of the
day and the zoning panel will go into
Vacant mode using only the Zone1
thermostat to control the equipment. Set
the switch to Occupied mode at the start of
the day.
The Vacation On screen will remain
displayed when in Vacation mode. Press
the No key to turn the Vacation mode off
and press the SAVE key to store your
selection.
Press the MENU key and then the NEXT
key to display the Manufacturer Info screen
and then press Yes to display the
information. The manufacturer’s name and
telephone number is displayed. Press
NEXT to display the Display Contractor
Info screen.
Press Yes to display the contractor
information. The contractor’s name and
telephone number is displayed if it was
entered at installation. Press NEXT to
display the Display Error Message screen.
Press Yes to display any error messages.
The examples show no error messages
and a short in the supply air temperature
sensor. Press NEXT to display the Display
Status screen.
Press Yes to display the Display HVAC
Status screen. Press NEXT to return to the
main menu.
Rev 8/22/13
OCCUPIED
VACANT
Display HVAC
Status Y/NEXT
Display Zone
Status Y/NEXT
Display Damper
Status Y/NEXT
Display Sensor
Temps Y/NEXT
Heating Stg1
NEXT
Zone 1 Heat1
NEXT
Damper 1 Open
NEXT
SAT 134 ODT 42
NEXT
Damper 2 Closed
NEXT
Damper 3 Open
NEXT
Damper 2 16%
NEXT
Zone 2 No Call
NEXT
Zone 3 Heat1
NEXT
Y
Y
Y
Y
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
NEXT
Display HVAC Status
Display Zone Status
Display Zone Damper Status
Display Sensor Temperatures
If Modulating Dampers Are
Used for Bypass
Press Yes to display the HVAC status. The
example shows the HVAC system is in first
stage heating. Press NEXT to display the
Display Zone Status screen.
Press Yes to display the status of each
zone thermostat. The example shows
Zone1 requesting stage 1 heating, Zone2
with no request and Zone3 requesting
stage1 heating. After displaying the last
zone thermostat, Press NEXT to display
the status of each zone damper.
Press Yes to display the status of each
zone thermostat. The example shows
Zone1 damper open, Zone2 damper
closed and Zone3 damper open. After
displaying the last zone damper, Press
NEXT to display the Display Sensor Temps
screen.
Press Yes to display the sensor
temperature readings if your system uses
sensors. The example shows the system
o
Discharge Air Temperature is 134 F and
o
the Outdoor Temperature is 42 F. Press
NEXT to return to the main menu.
If modulating dampers are being used
for bypass, the screen will shown the
percent a damper is partially open.