background image

Copyright IXXAT Automation GmbH 

USB-to-CAN compact - Manual, V1.6 

Appendix 

 

13

 

 

4.7

 

FCC Compliance 

Declaration of conformity 
This device complies with Part 15 of the FCC Rules. Operation is subject to the 
following two conditions: 

 

this device may not cause harmful interference, and 

 

this device must accept any interference received, including interference that 

may cause undesired operation. 

 
Class A digital device instructions: 
Note: This equipment has been tested and found to comply with the limits for a 

Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are de-
signed to provide reasonable protection against harmful interference when the 
equipment is operated in a commercial environment. This equipment generates, 
uses, and can radiate radio frequency energy and, if not installed and used in ac-

cordance with the instruction manual, may cause harmful interference to radio 
communications. Operation of this equipment in a residential area is likely to 
cause harmful interference in which case the user will be required to correct the 
interference at his own expense. 
 
 
 

Summary of Contents for USB-to-CAN compact

Page 1: ...The expert for industrial and automotive communication Manual USB to CAN compact Intelligent PC CAN Interface ...

Page 2: ...cts please contact IXXAT in written form by Fax 49 0 7 51 5 61 46 29 e Mail support ixxat de For customers from the USA Canada Fax 1 603 471 0880 e Mail techsupport ixxat com Copyright Duplication copying printing microfilm or other forms and the electronic distribution of this document is only allowed with explicit permission of IXXAT Automation GmbH IXXAT Automation GmbH reserves the right to ch...

Page 3: ...in allocation 6 3 1 1 USB connector 6 3 1 2 CAN bus connector 6 3 1 2 1 USB to CAN compact 6 3 1 2 2 USB to CAN compact RJ45 7 3 2 Displays 7 3 3 CAN bus termination 7 4 Appendix 8 4 1 Support 8 4 2 Returning hardware 8 4 3 Technical specifications 9 4 4 Accessories 10 CAN bus termination resistor 10 Cable adapter RJ45 to Sub D9M 10 4 5 Note on disposal of used devices 11 4 6 Declaration of confor...

Page 4: ......

Page 5: ...cation version 2 0 Hot plug compatible plug in during operation of computer Power supply via USB Infineon 16 bit microcontroller with 24MHz clock CAN controller PHILIPS SJA1000 with 24 MHz clock CAN bus interface according to ISO 11898 2 optional galvanic isolation 128 Kbyte RAM 512 Kbyte Flash 2 Installation 2 1 Software installation A driver is required to operate the interface For installation ...

Page 6: ... accord ing to the USB standard 3 1 2 CAN bus connector 3 1 2 1 USB to CAN compact The USB to CAN compact has a bus interface according to ISO 11898 2 The sig nals of the bus interface are connected to the 9 pin Sub D connector see table 3 1 The bus interface can be galvanically isolated from the CAN bus as an option Pin Nr Signal 1 2 CAN Low 3 GND 4 5 6 7 CAN High 8 9 Table 3 1 Pin allocation of ...

Page 7: ...CAN bus connector 3 2 Displays The USB to CAN interface has two 2 colored LEDs One LED is allocated to the USB bus the other to the CAN bus If the USB LED is lit green communication with the interface via the USB port is possible If communication is not possible the USB LED is lit red The CAN LED flashes green with every message received or transmitted without error If the CAN controller is in Err...

Page 8: ...t forms for your support request In order to fa cilitate our support work and enable a fast response please provide precise in formation on the individual points and describe your question or problem in de tail If you would prefer to contact our support department by phone please also send a support request via our website first so that our support department has the relevant information available...

Page 9: ...us 12kV Human Body Model Max number of CAN Nodes 120 Galvanic isolation 1000 V DC between CAN1 CAN2 and internal logic CAN Signal delay with galvanic isolation typically 50 ns Housing material ABS plastics Dimensions 80 X 45 X 20 mm Weight approx 100 g Operating temperature range 0 50 C Storage temperature range 40 C 85 C Power supply via USB Power consumption typically 250 mA max 400 mA Protectio...

Page 10: ...rough connector with internal 120 Ohm resistor available Ordering number 1 04 0075 03000 Picture A 1 Connections of the CAN bus termination resistor Cable adapter RJ45 to Sub D9M For the USB to CAN compact RJ45 there is an cable adapter RJ45 to Sub D9M available The length of the cable is 100 mm Ordering number 2 09 0000 00952 Picture A 2 Cable adapter RJ45 to Sub D9M ...

Page 11: ...n of 16 03 2005 When products supplied by IXXAT are no longer used the customer is obliged to dispose these products at his her own expense It is to be noted that unlike pri vately used devices B2C they may not be disposed of at the collection centers of public disposal contractors e g municipal recycling centers The statutory regu lations for disposal are to be complied with If products delivered...

Page 12: ...cle numbers 1 01 0087 10100 1 01 0087 10200 and USB to CAN compact RJ45 with the article numbers 1 01 0088 10100 1 01 0088 10200 do comply with the EC directives 2004 108 EC Applied harmonized standards in particular EN 55022 2006 A1 2007 EN 55024 1998 A1 2001 A2 2003 23 08 2011 Dipl Ing Christian Schlegel Managing Director IXXAT Automation GmbH Leibnizstrasse 15 88250 Weingarten ...

Page 13: ... has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are de signed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in ac cordance with the instructio...

Reviews: