RAMSES RT 2500 S Universal – User Guide
VI.4 List of the RT961B2S-Mk2 Configuration Parameters
All the parameters, their values and units are listed in Table 2. The grayed parameters are
only available in factory use of the MMI.
Table 2 – RT961B2S-Mk2 Configuration Parameters
Parameters Value
Unit
Individual Interrogation
IIF
Tonal
8 – 16
kHz
RAMSES
Code 0 - 23
CRF
Tonal
8 – 16
kHz
POSIDONIA
Code 0 - 23
RAMSES
Code 0 - 23
Common Interrogation
CIF
Tonal
8 – 16
kHz
RAMSES
Code 0 - 23
IRF
Tonal
8 – 16
kHz
POSIDONIA
Code 0 - 23
RAMSES
Code 0 - 23
Time
Blanking Time
0.4 to 10.0 (0.1 step)
s
Turn Around Time
0.02 to 0.2 (0.005 step)
s
Pressure
Link
Acoustic and/or Serial or none
Acoustic Threshold
191
188
185
dB
Acoustic Remote
Command Beacon
Arming
Release
Release with Pinger
Enable IIF Enable CIF
Disable IIF Disable CIF
Enable IIF Disable CIF
Enable CIF Disable IIF
Responder IIF
Responder CIF
Pinger ON
Pinger OFF
Diagnostic
Acoustic Reset
Telemetry On
Telemetry Off
Pressure
CAF
Tonal
8 – 16
kHz
POSIDONIA
Code 0 - 23
RAMSES
Code 0 - 23
Bit 0
read only
Tonal
8 – 16
kHz
Bit 1
read only
Tonal
8 – 16
kHz
RAMSES
Code 0 - 23
Operation Code
read only
0 - 99
Pinger
PRF
Tonal
8 – 16
kHz
POSIDONIA
Code 0 - 23
RAMSES
Code 0 - 23
Rate
1 to 10 (1 step)
s
Duration
1 to 60 (1 step)
min
MU – RT961SMk2 – AN - 001- A – June 2010
27
Summary of Contents for RAMSES RT 2500 S Universal
Page 1: ...RAMSES RT 2500 S Universal RT961S Mk2...
Page 2: ......
Page 10: ......
Page 67: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 57...
Page 68: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 58...
Page 69: ...RAMSES RT 2500 S Universal User Guide MU RT961SMk2 AN 001 A June 2010 59...