Hose Assembly
TOOLS REQUIRED:
13mm wrench
13mm socket wrench
SAFETY NOTE:
When installing the hose, it
is very important to have the machine safely
suspended by the Leg Extensions, Cribbing,
and/or Blocking to prevent a crush hazard.
STEP 1:
Locate the 36 inch diameter hose
with flanges pre-assembled.
STEP 2:
Use M8x20 bolts and M8 nylok nuts
to attach each the intake plate leg to the
bottom hose flange. Use 1 bolt/nut for each
strainer leg.
STEP 3:
Tighten all 4 bolts/nuts using 13mm
wrench and socket wrench.
STEP 4:
Tilt or hoist the core unit assembly
and slide the hose and intake plate assembly
beneath the core unit assembly. Line up the
upper hose flange slots with the core machine
unit flange slots.
STEP 5:
Use M8x20 bolts and M8 nylok nuts
to attach the upper hose flange to the core unit
assembly flange.
STEP 6:
Tighten all 8 bolts/nuts using 13mm
wrench and socket wrench.
© 2020 Ixom | www.medoraco.com | 866 - 437 - 8076 | [email protected]
Equipment Assembly
458_10264_20200528