IXL 10324 User Manual Download Page 5

Wiring Diagrams

Fig. 5: Wiring diagram.

IXL Eco Ventflo

Installation

Important considerations before installing

•  Joists, beams and rafters shall not be cut or notched to install the appliance.
•  This unit has an IPX4 rating which means it is suitable for Zone 1 installations and can be installed 

directly above a shower or bath.

•  For the exhaust fan to work efficiently, replacement air of a volume equivalent to what is being 

extracted must be able to enter the room. In general this air would be drawn under the door or 

through a slightly open window. If the room is airtight the fan will function poorly.

•  This product is designed for installation in flat ceiling only. Do not mount it on a sloping ceiling  

or vertical wall.

Fig. 7: Mounting clips open

Fig. 6: Mounting clips closed 

IXL Eco Ventflo

1.  Locating the unit – Before commencing any 

cutting, check in the ceiling space that there are 

no obstructions such as ceiling joists and that 

there is sufficient clearance for the housing.  

Check that the electrical wiring can be routed from 

the wall switches to the mounting location.

2.  Prepare the ceiling – Using the template provided 

on page 15, mark the ceiling with a pencil outline 

and cut out the required hole (10324 needs 244 

mm dia. & 10326 needs 294 mm dia. hole).

3.  Remove the grille.
4.  Plug the fan into the power point.
5.  Ensure that the mounting clips are in the closed 

position, then insert fan into ceiling cut out.

6.  Using a screwdriver (or a battery driver with a low 

torque setting) partially tighten the screws.   

This will move the mounting clips into the open 

position and hold the unit to the ceiling.

7.  Rotate the unit so that the grille direction  

lines on the body are aligned with the walls.  

These lines show the orientation of the fascia 

grille when installed.  

8.  Tighten the screws.  Do not over tighten as this 

can damage plasterboard.

9.  Fit grille onto unit.  Once fitted the grille can be 

adjusted to better align with the walls.

8

10324

: 0.13A 50Hz,  

10326

: 0.25A 50Hz

Summary of Contents for 10324

Page 1: ...User Guide IXL Eco Ventflo Model 10324 200mm Extraction Rate 340m3 h Model 10326 250mm Extraction Rate 490m3 h Electrical Rating 230 240 V 50 Hz...

Page 2: ...y a licensed electrician Switches and other controls must not be located where they can be touched by a person in the bath or shower Warning Do not use this appliance for functions other than those de...

Page 3: ...cated on the back of this booklet For further details and advice on ventilation products and tips visit the IXL Ventilation Selection Guide on our website www sampfordixl com au 4 If the appliance doe...

Page 4: ...2 DRN 3 4 5 6 7 8 9 10 11 12 g MASS VENTFLO 200 AXIAL FAN VOLUME mm3 Fig 2 Adequate open space in the roof cavity is required A B FLAPS DRN CHK APP REL 3rd ANGLE PROJECTION THIS DRAWING AND DESIGN RE...

Page 5: ...no obstructions such as ceiling joists and that there is sufficient clearance for the housing Check that the electrical wiring can be routed from the wall switches to the mounting location 2 Prepare...

Page 6: ...not be installed in a place that suffers from severe water leakage 1 Shut power off before cleaning or maintenance 2 Remove grille and wipe it with care using a damp soft cloth with a mild detergent...

Page 7: ...horised Dealer or Reseller c will not apply where the defect in or failure of the product is attributable to misuse abuse accident or non observation of the manufacturer s instructions This product mu...

Page 8: ...Notes IXL Eco Ventflo Template for Cut Out IXL Eco Ventflo 14...

Page 9: ...ers Sampford IXL Pty Ltd Service Department 421 Smith St Fitzroy Victoria 3065 Australia Phone 1300 727 421 Fax 1300 727 425 aftersalesservice sampfordixl com au info sampfordixl com au www sampfordix...

Reviews: