13
IMPORTANT NOTES:
• The Tap is shipped with switches 1 and 2 in the ON position (LFD and Auto-
negotiation active).
• If you are using a fixed-speed setting, all devices connected to the Tap should
also be set to that same speed. Furthermore, you should set only one speed
switch to ON (up position). If more than one speed switch is set to ON, the Tap
uses the fastest speed.
• When the unit is shipped, dip switch 8 is set to the down position. After you
connect power, make sure the power is ON for 12 hours to fully charge the
backup battery. In the event of a power outage, the Zero Delay Tap can remain
powered for 3 to 5 hours with a fully charged battery.
• If you plan to store or power down this unit for longer than 2 hours, follow this
procedure:
Step 1 - Set the dip switch 8 to the up position.
Step 2 - Disconnect all power sources.
Step 3 - When the power sources have been disconnected, set dip
switch 8 to the down position.
Step 4 - Store the unit.
• When you redeploy the unit, ensure dip switch 8 is in the down position. Then
connect to the power source.