iWiscloud Wis-S-CH Operating Manual Download Page 4

P a g e

4 | 9

2. Each smart sensor is designed with two optional power relays [see section

2.13 for details] which can be used to power control other electronic products.

These relays are activated whenever the smart sensor defined upper limit is

exceeded.

3. Each smart sensor (other than the PM2.5 model) also has an option to

provide a 4-20mA varying electric power source to a single target.

4. For the advanced smart sensor model, each smart sensor can also capture

and perform relay of 315/433Mhz control signals.

2. Configuring iWiscloud Smart Sensor

In this section, we would explain on the configuration options, following settings ->

configuration in chronological order.

2.1.

Main display screen

1. The top value indicates the reading of the smart sensor detection attribute

(depending on smart sensor model)

2. The next row with a loud speaker icon indicates the detected sound level.

The higher the sound level detected, the more

_

would appear.

3. The last row indicates the luminosity level detected.

4. If the smart sensors are paired with iWiscloud control centre, the sensor

exact readings can be obtained from the cloud as seen in below diagram.

Summary of Contents for Wis-S-CH

Page 1: ...oid if product is found to be tampered with Notice As this product constantly improve the pictorial diagram might be an indication of the actual product delivered Wiscloud is grateful for your choice...

Page 2: ...ty standards and achieved CE certifications Side view Back view 1 1 Product specifications Smart Sensor Model No Detection range Accuracy Oxygen Wis S O2 0 25 0 3 Formaldehyde Wis S CH 0 0 3mg m3 0 00...

Page 3: ...onitor alert or obtain precise information of the environment 1 4 Exterior design Our smart sensors square or circular shaped exterior shells are made up from Acrylonitrile Butadiene Styrene ABS plast...

Page 4: ...form relay of 315 433Mhz control signals 2 Configuring iWiscloud Smart Sensor In this section we would explain on the configuration options following settings configuration in chronological order 2 1...

Page 5: ...Room Setting In this section the smart sensor can be configured to be operating in one of the default location zone within home This is to facilitate for the iWiscloud control center in identifying t...

Page 6: ...alue is on which meant the smart sensor will blink in red light when defined limits are breached However when this setting is turned off regardless if the warning audio selection the smart sensor will...

Page 7: ...ratu re Wis S TH Y Y Y 2 13 Setting up the electrical relays Please note that the electronic relays only support up to 500W and it should be installed only by qualified trained electrician The electri...

Page 8: ...vice detection accuracy Avoid frosting the smart sensor hive surface area as it would damage the hive structure and permanently damage device capabilities 4 Product listing 4 1 iWiscloud smart sensor...

Page 9: ...does not cover missing accessories or external parts of the product Such claim should be made within 3 days from the date of original retail purchase with the supplying agent For the avoidance of doub...

Page 10: ...cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to rad...