www.iwata-airbrush.com
Customer Support 503-253-7308 M-F, 8am-4:30pm PST | [email protected] | www.iwata-airbrush.com/blog/contact-us
Quiet Oil-Free Air Compressor
13
TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
POSSIBLE SOLUTIONS
Pressure drop in the tank.
Air leaks at connections.
Let the compressor build pressure in
the tank, to the maximum pressure
if possible. brush soapy water on air
connections and look carefully for air
bubbles. Tighten leaky connections. If
the problem persists, contact the seller
for further advice.
The unloader valve leaks when
the compressor is idle.
unloader valve seal is defective.
Let the air in the air tank flow out until
all the pressure is released. Then remove
the unloader valve plug and clean the
valve seal. If necessary, replace the seal
and then reinstall all components.
The compressor stopped and does
not start.
The thermal protector turned on
because the motor is overheating.
Check that the main voltage corresponds
to the air compressor specifications. An
extension cord that is too thin or too
long can cause a voltage drop and cause
the motor to overheat.
Excessive use (over 1 hour continuous
use) can cause the motor to overheat
Allow the motor to cool down.
Motor windings are burned out.
Contact Customer Support.
The motor does not start and makes a
humming noise.
Capacitor is burned out.
Contact Customer Support.
The motor does not start or starts slowly. Low voltage supply to the motor.
Check that the main voltage corresponds
to the air compressor specifications.
An extension cord that is too thin or
too long can cause a voltage drop. Use
heavy duty extension cords.
Ensure that the air compressor is
plugged into a fully functional power
outlet.
The compressor is noisy with metallic
clangs.
Compressor head gasket or reed valve
is damaged.
Stop the compressor and contact
the dealer.
The compressor does not reach the
maximum pressure.
Compressor head gasket or reed valve
is faulty.
Stop the compressor and contact
the dealer.
The compressor doesn’t seem to provide
as much air as it did when new and/or
the compressor cuts off within a much
shorter time period.
The pressure switch needs adjusting.
Stop the compressor and contact
the dealer.
The tank is full of water due
to condensation.
Open the drain valve and release
the water from the tank.
The motor pump unit does not stop
when the tank pressure reaches its
maximum working pressure (125 PSI).
Pressure switch defective or needs
adjusting.
Stop the compressor immediately
and contact Customer Support.