TROUBLESHOOTING PROCEDURES
Symptom
•Bubbles in color cup or bottle
•Double Line
•Not Spraying
Problem
•Loose nozzle cap
•Improper nozzle to body connection
•Cracked or damaged nozzle
•Dried paint on needle tip (Tip-Dry)
•Dirty airbrush
•Debris on nozzle tip
•Bent needle
•Cracked or damaged nozzle
•Loose needle chucking nut
•Needle stuck
•SAR only: Reset needle
•Improper air pressure
•Paint too thick
•Bottle vent hole is plugged
•Clogged nozzle
•Cracked or damaged nozzle
Solution
•Tighten (#2) finger tight
•See nozzle (#3) to reseat the nozzle
•See nozzle (#3) to replace the nozzle
•See cleaning the needle
•See cleaning the airbrush between colors
•See cleaning the needle
•See nozzle (#3) and clean nozzle with toothpick
•See needle (#11) to replace needle
•See nozzle (#3) to replace the nozzle
•Finger tighten (#12)
•Pull/break-free needle (#11)
•See cleaning the needle (SAR)
•See specific compressor instructions to
raise or lower the air pressure
•See paint preparation
•Use pushpin to unclog vent hole
•See nozzle (#3) and clean nozzle with toothpick
•See nozzle (#3) to replace the nozzle