Installation
1.Installing and connecting the pump
・ Decide where the pump should be installed and secure a suitable space (see Examples of installations A to D).
Examples of pump installations
Air supply
Exhaust
A
C
B
D
For optimal performance try to keep the suction lift as short as possible.
To protect the diaphragms from abnormal damage or breakage, the inlet pressure must be kept below the following values:
※ PTFE Diaphragms
: 0.02 MPa [3 psi] (height 2 m [6.6 ft]) During operation
: 0.05 MPa [7 psi] (height 5 m [16.4ft]) When not in operation
※ All other Diaphragms
: 0.1MPa [14 psi] (height 10 m [32.8ft])
(The above values are when transferring fresh water under ambient temperature. Depending on the liquid these values may change.)
When installing the pump, please use a method that allows the pump to absorb vibration caused during pump operation.
- 10 -