![IWAKI PUMPS MXM Series Instruction Manual Download Page 32](http://html1.mh-extra.com/html/iwaki-pumps/mxm-series/mxm-series_instruction-manual_2098029032.webp)
■
Dismantlement
1. Flush out chemical liquid from the pump by
a flushing line. Then remove the drain cap to
empty the pump.
WARNING
Wear protective clothing such as goggles,
rubber gloves, etc. during maintenance.
Coming in contact with a harmful chemi-
cal liquid may cause eye or skin trouble.
2
. Remove hex. socket head bolts from the front
casing to remove it from a bracket. Try to pull
out the front casing straight from the bracket so
as no to damage the spindle in it. The spindle
may stay in the front casing after removal. In this
case, take care not to loose the rear thrust.
CAUTION
A strong impact may crack the front cas-
ing. Be careful not to hit it.
Front casing
Drain cap
- 30 -
Front casing
Maintenance
Front casing
Bracket