- 4 -
● Earthing
Risk of electrical shock. Do not run the pump without earthing. Secure earth
protection to reduce the risk.
● Install an earth leakage breaker
Risk of electrical shock. Do not run the pump without a leakage breaker.
Secure a leakage breaker to reduce the risk.
● Limitations on working and storage areas
Do not install or store the pump in the following places where...
1. Ambient temperature exceeds 40 ºC or falls below 0 ºC.
2. Under a flammable/explosive atmosphere (Except explosion-proof type).
3. Under wind & rain or in a dusty/humid place (Except outdoor-use type).
4. The pump is subject to vibration.
5. Under a corrosive atmosphere such as chlorine gas.
●
Starting
The pump doesn't have an ON-OFF switch. The pump starts as a power
cable is plugged in.
● Foreign matter
When foreign matters enter the pump, turn off power at once and remove
them. Using the pump with foreign matters may result in failure.
●
Pump disposal
Any used or damaged pump must be disposed of in accordance with local
laws and regulations as an incombustible (Consult a licensed industrial waste
products disposing company.).
●
Static electricity
When low electric conductivity liquids such as ultra-pure water and fluor inac-
tive liquid (e.g. Fluorinert
TM
) are handled, static electricity may generate in
the pump and may cause static discharge. Take countermeasures to remove
static electricity.