505 "H" type
507/657/6510 Standard
[11]
Allowable pressure limit
See the table 1~5 for allowable pressure limits of each model.
See that the discharge pressure does not exceed the allowable pressure limit.
- 18 -
425 Standard
"H" type
MDF-L250
Standard
0.3
0.16
MPa
0
˚C
90
100
Temperature
MDF-L422/423/425
0.45
0.4
MPa
0
˚C
100
Temperature
422/423
Standard
"H" type
MDF-L401
Standard
0.3
0.24
MPa
0
˚C
90
100
Temperature
MDF-L505/507/657/6510
0.5
0.4
0.3
MPa
0
˚C
70
90
100
Temperature
Table 1
Table 4
Table 3
Table 2
NOTE
MDF-L6515
0.6
0.5
MPa
0
˚C
70
100
Temperature
Standard
Table 5
NOTE
*AFLAS
®
O ring
Above 10 ˚C
505 Standard