80
:HDUSDUWUHSODFHPHQW
:HDUSDUWUHSODFHPHQW
To run the pump for a long period, wear parts need to be replaced periodically.
It is recommended that the following parts are always stocked for immediate
replacement. Contact us or your nearest distributor for detail.
3UHFDXWLRQV
6ROXWLRQLQWKHGLVFKDUJHOLQHPD\EHXQGHUSUHVVXUH5HOHDVHWKHSUHV
-
VXUHIURPWKHGLVFKDUJHOLQHEHIRUHGLVFRQQHFWLQJSOXPELQJRUGLVDVVHP
-
EO\RIWKHSXPSWRDYRLGVROXWLRQVSUD\
5LQVHZHWHQGVWKRURXJKO\ZLWKWDSZDWHU
(DFKWLPHWKHSXPSKHDGLVGLVPDQWOHGUHSODFHWKHGLDSKUDJP2ULQJV
YDOYHJDVNHWVDQGYDOYHVHWVZLWKQHZRQHV
Wear part list
3DUWV
RI
SDUWV
(VWLPDW
-
HGOLIH
3XP
S
9DOYHVHW
9&9+3&3+7&
6+
FC
3&3
VHWV
8000
KRXUV
'LDSKUDJP
7
32
1
$XWRPDWLFDLU
YHQWYDOYHVHW
35
34 33 30 34
31
17
1
*
7KHKLJKSUHVVXUHW\SHVKDYHDUHDUGLDSKUDJPVKHHWRQWKHEDFNVLGHRIWKHGLDSKUDJP
*
:HDUSDUWGXUDWLRQYDULHVZLWKWKHSUHVVXUHWHPSHUDWXUHDQGFKDUDFWHULVWLFVRIOLTXLG
*
7KHHVWLPDWHGOLIHLVFDOFXODWHGEDVHGRQWKHFRQWLQXRXVRSHUDWLRQZLWKFOHDQZDWHUDW
DPELHQWWHPSHUDWXUH
*
7KHSDUWGLDSKUDJPVKHHWLVSURYLGHGRQO\+3&+DQG3++W\SHV
14
11
13
12
11
13
12
17
14
11
13
12
11
13
12
17
28
28
11
13
12
28
28
11
13
12
14
14
11
13
12
14
17
11
13
12
14
14
11
52
13
12
14