background image

© 2010 IWAKI CO.,LTD.

Iwaki Air Pump
APN-110-D3

Instruction manual

Thank you for choosing our product.

Please read through this instruction manual before use.

This instruction manual describes important precautions and 

instructions for the product. Always keep it on hand for quick 

reference.

Saf

ety

 in

struc

tion

s

O

utlin

e

In

sta

llat

io

n

O

pe

rat

io

n

M

ai

nt

ena

nc

e

Sp

eci

fic

at

io

n

T761 '11/04

                                                                                                                                                        (   )Country codes

IWAKI CO.,LTD.

 6-6 Kanda-Sudacho 2-chome Chiyoda-ku Tokyo 101-8558 Japan

TEL:(81)3 3254 2935 FAX:3 3252 8892(http://www.iwakipumps.jp)

Australia IWAKI Pumps Australia Pty. Ltd.

TEL : (61)2 9899 2411 FAX : 2 9899 2421

Italy

IWAKI Italia S.R.L.

TEL : (39)0444 371115 FAX : 0444 335350

Austria

IWAKI (Austria) GmbH

TEL : (43)2236 33469 FAX : 2236 33469

Korea

IWAKI Korea Co.,Ltd.

TEL : (82)2 2630 4800 FAX : 2 2630 4801

Belgium IWAKI Belgium n.v.

TEL : (32)1367 0200

FAX : 1367 2030

Malaysia IWAKIm Sdn. Bhd.

TEL : (60)3 7803 8807 FAX : 3 7803 4800

China

IWAKI Pumps (Shanghai) Co., Ltd.

TEL : (86)21 6272 7502 FAX : 21 6272 6929

Norway

IWAKI Norge AS

TEL : (47)66 81 16 60 FAX : 66 81 16 61

China

IWAKI Pumps (Guandong) Co., Ltd.

TEL : (86)750 3866228 FAX : 750 3866278

Singapore IWAKI Singapore Pte. Ltd.

TEL : (65)6316 2028 FAX : 6316 3221

China

GFTZ IWAKI Engineering & Trading (Guangzhou)

TEL : (86)20 8435 0603 FAX : 20 8435 9181

Spain

IWAKI Iberica Pumps, S.A.

TEL : (34)943 630030 FAX : 943 628799

China

GFTZ IWAKI Engineering & Trading (Beijing)

TEL : (86)10 6442 7713 FAX : 10 6442 7712

Sweden

IWAKI Sverige AB

TEL : (46)8 511 72900 FAX : 8 511 72922

Denmark IWAKI Nordic A/S

TEL : (45)48 24 2345

FAX : 48 24 2346

Switzerland IWAKI (Schweiz) AG

TEL : (41)26 674 9300 FAX : 26 674 9302

Finland

IWAKI Suomi Oy

TEL : (358)9 2745810 FAX : 9 2742715

Taiwan

IWAKI Pumps Taiwan Co., Ltd.

TEL : (886)2 8227 6900 FAX : 2 8227 6818

France

IWAKI France S.A.

TEL : (33)1 69 63 33 70 FAX : 1 64 49 92 73

Taiwan

IWAKI Pumps Taiwan (Hsin-chu) Co., Ltd.

TEL : (886)3 573 5797 FAX : (886)3 573 5798

Germany IWAKI EUROPE GmbH

TEL : (49)2154 9254 0 FAX : 2154 9254 48

Thailand IWAKI (Thailand) Co.,Ltd.

TEL : (66)2 322 2471 FAX : 2 322 2477

Holland

IWAKI EUROPE NL Branch

TEL : (31)547 293 160 FAX : 547 292 332

U.K.

IWAKI Pumps (UK) LTD.

TEL : (44)1743 231363 FAX : 1743 366507

Hong Kong IWAKI Pumps Co., Ltd.

TEL : (852)2 607 1168 FAX : 2 607 1000

U.S.A.

IWAKI AMERICA Inc

TEL : (1)508 429 1440 FAX : 508 429 1386

Indonesia IWAKI Singapore (Indonesia Branch)

TEL : (62)21 690 6606 FAX : 21 690 6612

Vietnam

IWAKI Pumps Vietnam Co.,Ltd.

TEL : (84)613 933456 FAX : 613 933399

Summary of Contents for APN-110-D3

Page 1: ...td TEL 86 7503866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pum...

Page 2: ...ncy is found immediately contact your distribu tor a Check if the delivery is correct Check the nameplate to see if the information such as model codes discharge capacity and discharge pressure are as...

Page 3: ...p structure Operating principle 12 Part names 13 Identification codes 14 Installation 15 Pump mounting 15 Pipework 16 Tube connection 16 Wiring 17 Power External signal cables 17 Before work 17 Rated...

Page 4: ...ction 23 Daily inspection 23 Wear part replacement 24 Wear part list 24 Before service 24 Diaphragm replacement 25 Valve replacement 26 Specification Outer dimension 27 Specification 27 Outer dimensio...

Page 5: ...anies each precaution suggesting the use of Caution Pro hibited actions or specific Requirements I ndicates mishandling could lead to personal injury or property damage CAUTION Caution marks Prohibiti...

Page 6: ...turer s responsibility for any failure or injury resulting from alternations to the pump Use specified power only Do not apply power other than that specified on the nameplate Otherwise failure or fir...

Page 7: ...pump In a flammable atmosphere In a dusty humid environment Where operating or storage temperature can fall below 5 C or 0 C or exceed 40 C In direct sunlight or wind rain Spill precautions Ensure pr...

Page 8: ...ond the extent of the instructions Do not use a damaged pump Use of a damaged pump could lead to an electric shock or death Disposal of a used pump Dispose of any used or damaged pump in accordance wi...

Page 9: ...mp Otherwise the pump performance may reduce or the lives of the valve and diaphragm remarkably shorten Do not install the pump in a corrosive or flamma ble gas atmosphere Keep good ventilation in a w...

Page 10: ...nt must be below the pump position Or siphon action back flow may result Use care handling the pump Do not drop An impact may affect pump performance Do not use a pump that has been damaged to avoid t...

Page 11: ...sk of burning Pump and pipe surface tempera tures rise high along with liquid temperature Do not touch the pump or pipe surface directly during operation or right after operation Always use a suction...

Page 12: ...type air pump with a brushless DC motor The rotary motion of the motor is converted through a connecting rod to the reciprocation of the diaphragm in the pump chamber where gas is transferred from the...

Page 13: ...mes Outlet Base Always fix with screws Specification label Use the pump accord ing to the specifica tions on the label Pump head Not capable of liquid transfer Air transfer purpose only Inlet Pump bod...

Page 14: ...d e f a Pump size b Pump head K In line type L Parallel type c Diaphragm Valve materials N NBR E EPDM V FKM d Pump connection No code 8 tube connection X Rc1 4 female thread connection JIS taper pipe...

Page 15: ...n off power to stop the pump and related devices before service is performed If you notice any abnormal or dangerous conditions suspend operation immediately and inspect solve problems Do not operate...

Page 16: ...he pump inlet outlet for the prevention of gas ingress leak or other failure Do not have tubing bent or pressed Otherwise the tube end may break Connect tubes into the inlet and outlet Push the tubes...

Page 17: ...ltage See the spec label When an external fuse is used and it has blown always solve the root cause of blowout Be sure to unplug the power cable before investigation If the fuse blows frequently the s...

Page 18: ...stem is free from the inductive noise at start up Noise accompanies the high speed switching of the drive circuit Check it does not affect peripheral devices If a power source is shared with the induc...

Page 19: ...e connected the other way around pumping process is inverted c Check that every tube connection is secured d Check that electrical wiring is properly done without the possibility of short circuit and...

Page 20: ...ine pressure at the time of power recovery After starting check a pressure gauge to see if suction and dis charge line pressure are correct and an air flow meter to see if the specified air flow is ob...

Page 21: ...nd operation im mediately and check the following points If the following measures do not help remove problems contact your nearest distributor States Possible causes Solutions The pump does not run P...

Page 22: ...e pressure is too low Wrong tubing or poor connection Check and fix tubing Pump head mounting screws are loose Tighten the screws Diaphragm fixing screw is loose Tighten the screw Diaphragm is broken...

Page 23: ...When wear parts come to the life limit replace them by new ones Contact your distributor for detail No States Points to be checked 1 Pumping If the specified power voltage starting current are observe...

Page 24: ...es with new ones Application Estimated life Valve Diaphragm All APN 110 models 8000hr 8000hr Wear part duration varies with the pressure temperature and characteristics of gas The estimated life above...

Page 25: ...plate onto the under retainer plate Secure the retainer plate and dia phragm Apply the LOCTITE 222 to the dia phragm fixing screw and tighten it by 1 96N m Push down the diaphragm until it bottoms out...

Page 26: ...Check the air flows from the inlet to the outlet Push down the diaphragm until it bottoms out Secure the pump head unit onto the bracket with the fixing screws by 1 96N m NOTE Do not loosen the bracke...

Page 27: ...serve the maximum allowable discharge pressure of 0 05MPa Allowable gas temperature range is 0 40 C Allowable ambient temper range is 5 40 C Both the inlet and outlet of the pump are Rc1 4 female thre...

Page 28: ...0 12 8 129 2 Rc1 4 or 2 G1 4 134 29 91 74 Tube connection 101 3 87 98 74 65 61 32 47 99 34 66 21 33 8 00 0 02 0 04 0 06 0 08 0 10 0 2 10 15 Discharge pressure 0MPa Vacuum 101 3kPa abs Vacuum 87 98kPa...

Page 29: ...ty No Part names Q ty 1 Pump head 1 18 Under retainer plate 1 2 Valve 1 19 Connecting rod 1 3 Valve seat 1 20 Bracket 1 4 Diaphragm 1 40 Motor 1 5 Retainer plate 1 60 Set screw 2 8 Eccentric shaft 1...

Page 30: ...30...

Page 31: ...31...

Page 32: ...td TEL 86 7503866228 FAX 7503866278 Singapore IWAKI Singapore Pte Ltd TEL 65 63162028 FAX 63163221 China GFTZIWAKIEngineering Trading Guangzhou TEL 86 2084350603 FAX 2084359181 Spain IWAKI Iberica Pum...

Reviews: