Heat pump
Sound pressure level
Lp - ear (dBA)
Optima 1000
53
Optima 1300
61
Sound levels
The table describes the sound levels stated as sound pressure level.
Sound pressure level:
Sound pressure level is defi ned as the sound level, which at an ear level
of 1.8 metres, is perceived one metre from the heat pump. Measured in a
sound measurement room without echo at an outdoor temperature of +7ºC
and 50ºC fl ow temperature.
Example:
When the heat pump is installed outside with free sound propagation the
sound level drops by 6dBa with each doubling of distance.
Menu
Setting
Factor y
setting
2.4
DHW hysteresis
5º
4.1
Clock setting HP
not active
4.1.1
Setting level HP
0º
4.3
Clock setting DHW
not active
5.1
Op. mode selection
A
5.2
Conn. cap. electric cassette
2/3
5.4
Additional heat only
off
5.5
Additional heat yes/no
yes
5.7
External controls
0
5.11
Fan operation options
off
8.1
Additional heat timer
60 minutes
8.3.1
Time delay SV1
30 minutes
8.3.2
Time delay stop boiler
60 minutes
8.3.3
Mix. valve curve neutral zone 3ºC
8.3.4
Setting of ramp time open
20 minutes
8.3.5
Setting of ramp time close
3 minutes
8.3.6
Setting of SV1 runtime
1 minute
Menu
Setting
Factor y
setting
1.1
Temp. incr. / decr.
4
1.2
Temp. fi ne-tune
0º
1.3
Heat curve adjustm.
0º
1.4
Heat curve hysteresis
5º
1.5
Mix. valve incr/decr
4
1.6
Mix. valve fi ne-tune
0º
1.7
Mix. valve curve adjustm.
0º
1.8
Mix. valve curve neutral zone
3º
1.9
Mix. valve curve max. temp.
60º
1.10
Room temperature
20º
1.11
Room sensor infl uence
5
1.12
Holiday function
0 days
1.13
Remote control temperature
not active
1.14
Summer disconnection
18º
1.17
Return thermostat hysteresis
5º
2.1
Extra hot water
0 hours
2.2
DHW peak interval
not active
2.3
DHW temperature
45º
Technical information
Optima 1000
Distance
Lp - ear (dBa)
1 metre
53
2 metres
47
4 metres
41
8 metres
35
Technical information
The heat pump’s factory settings
The table shows the factory settings of all the settings that can be changed by the installer.