background image

Ivoclar Vivadent AG

Bendererstrasse 2
FL-9494 Schaan
Liechtenstein
Tel. +423 235 35 35
Fax +423 235 33 60
www.ivoclarvivadent.com

Ivoclar Vivadent Pty. Ltd.

1 – 5 Overseas Drive
P.O. Box 367
Noble Park, Vic. 3174
Australia
Tel. +61 3 979 595 99
Fax +61 3 979 596 45
www.ivoclarvivadent.com.au

Ivoclar Vivadent GmbH

Bremschlstr. 16
Postfach 223
A-6706 Bürs
Austria
Tel. +43 5552 624 49
Fax +43 5552 675 15
www.ivoclarvivadent.com

Ivoclar Vivadent Ltda.

Rua Maestro João Gomes de
Araújo 50; Salas 92/94
Sao Paulo, CEP 02332-020
Brazil 
Tel. +55 11 69 59 89 77  
Fax +55 11 69 71 17 50
www.ivoclarvivadent.com

Ivoclar Vivadent Inc.

2785 Skymark Avenue, Unit 1
Mississauga
Ontario L4W 4Y3
Canada
Tel. +1 905 238 57 00
Fax +1 905 238 5711
www.ivoclarvivadent.us.com

Ivoclar Vivadent 
Marketing Ltd.

Rm 603 Kuen Yang 
International Business Plaza
No. 798 Zhao Jia Bang Road
Shanghai 200030
China
Tel. +86 21 5456 0776
Fax. +86 21 6445 1561
www.ivoclarvivadent.com

Ivoclar Vivadent 
Marketing Ltd.

Calle 134 No. 13-83, Of. 520
Bogotá
Colombia
Tel. +57 1 627 33 99
Fax +57 1 633 16 63
www.ivoclarvivadent.com

Ivoclar Vivadent SAS

B.P. 118
F-74410 Saint-Jorioz
France
Tel. +33 450 88 64 00
Fax +33 450 68 91 52
www.ivoclarvivadent.fr

Ivoclar Vivadent GmbH 

Dr. Adolf-Schneider-Str. 2
D-73479 Ellwangen, Jagst
Germany
Tel. +49 (0) 79 61 / 8 89-0
Fax +49 (0) 79 61 / 63 26
www.ivoclarvivadent.de

Ivoclar Vivadent 
Marketing Ltd

114, Janki Centre
Shah Industrial Estate
Veera Desai Road,
Andheri (West)
Mumbai 400 053
India
Tel. +91 (22) 673 0302
Fax. +91 (22) 673 0301
www.ivoclarvivadent.firm.in

Ivoclar Vivadent s.r.l.

Via dell’Industria 16
I-39025 Naturno (BZ)
Italy
Tel. +39 0473 67 01 11
Fax +39 0473 66 77 80
www.ivoclarvivadent.it

Ivoclar Vivadent S.A. de C.V.

Av. Mazatlán No. 61, Piso 2
Col. Condesa
06170 México, D.F.
Mexico
Tel. +52 (55) 5062-1000
Fax +52 (55) 5062-1029
www.ivoclarvivadent.com.mx

Ivoclar Vivadent Ltd

12 Omega St, Albany
PO Box 5243 Wellesley St
Auckland, New Zealand
Tel. +64 9 914 9999
Fax +64 9 630 61 48
www.ivoclarvivadent.co.nz

Ivoclar Vivadent 
Polska Sp. z.o.o.

ul. Jana Pawla II 78
PL-01-501 Warszawa
Poland
Tel. +48 22 635 54 96
Fax +48 22 635 54 69
www.ivoclarvivadent.pl

Ivoclar Vivadent 
Marketing Ltd.

180 Paya Lebar Road
# 07-03 Yi Guang Building
Singapore 409032
Tel. 65-68469183
Fax 65-68469192

Ivoclar Vivadent S.A.

c/Emilio Muñoz, 15 
Esquina c/Albarracín
E-28037 Madrid
Spain
Tel. + 34 91 375 78 20
Fax + 34 91 375 78 38
www.ivoclarvivadent.com

Ivoclar Vivadent AB

Dalvägen 14
S-169 56 Solna
Sweden
Tel. +46 8 514 93 943
Fax +46 8 514 93 940
www.ivoclarvivadent.se

Ivoclar Vivadent UK Limited

Ground Floor Compass Building
Feldspar Close
Warrens Business Park
Enderby
Leicester LE19 4SE
United Kingdom
Tel. +44 116 284 78 80
Fax +44 116 284 78 81
www.ivoclarvivadent.co.uk

Ivoclar Vivadent, Inc.

175 Pineview Drive
Amherst, N.Y. 14228
USA
Tel. +1 800 533 6825
Fax +1 716 691 2285
www.ivoclarvivadent.us.com

Version: 2
Date information prepared: 03/2006
Valid as of Software V1.60

This apparatus has been developed solely for use in dentistry. Start-up and 
operation should be carried out strictly according to the Operating Instructions.
Liability cannot be accepted for damages resulting from misuse or failure to
observe the Instructions. The user is solely responsible for testing the apparatus
for its suitability for any purpose not explicitly stated in the Instructions. 
Descriptions and data constitute no warranty.

Printed in Austria 
© Ivoclar Vivadent AG, Schaan/Liechtenstein
598567/0306/e

Ivoclar Vivadent – worldwide

Summary of Contents for Programat P300

Page 1: ...Operating Instructions Programat P300...

Page 2: ...2...

Page 3: ...Explanation of the key functions 5 3 Program structure 5 4 Adjustable parameters and possible value ranges 5 5 Settings test programs and information 5 6 Explanation of the symbols on the display 5 7...

Page 4: ...hose connection 23 Rubber feet 24 Protective cover vacuum 25 Furnace head housing 26 Thermocouple plug 27 Plug fuse 28 Heater plug 29 Heater plug socket 30 Thermocouple plug socket 32 Leaf spring 33 A...

Page 5: ...5 40 25 34 6 10 35 23 47 33 1 7 5 2 3 4 8 9...

Page 6: ...6 37 39 36 11 38 25 19 13 12 49 26 30 29 50 51 27 28 11 32 43 12 13 15 19 46 21 17 18 16...

Page 7: ...y temperature 82 Closing time 83 Temperature increase 84 Holding temperature 85 Holding time 86 Vacuum on 87 Vacuum off 88 Long term cooling 90 Open furnace head 91 Close furnace head 92 Numeric keys...

Page 8: ...joy working with the P300 1 2 Introduction The signs and symbols in these Operating Instructions facilitate the finding of important points and have the following meanings Risks and dangers Important...

Page 9: ...must be observed The furnace must be operated under the indicated environmental and operating conditions Chapter 9 The Programat P300 must be properly maintained 2 1 1 Risks and dangers The furnace he...

Page 10: ...e skin grease contamination as the parts will be prematurely dama ged 2 1 12 Risk of crushing and burn hazard Never reach under the furnace head with the hand or other parts of the body during operati...

Page 11: ...nditions over an extended period of time Use only original spare parts The temperature range for faultless operation is 5 C to 40 C 41 F to 104 F If the furnace has been stored at very low temperature...

Page 12: ...uum may be created with a vacuum pump The firing process is controlled with the corresponding electronic con trols and a software Moreover the set and actual temperatures are continuously compared 3 4...

Page 13: ...ly use the two corresponding inserts Fold the side flaps 2 and combine the two packaging parts by means of the transportation flaps The packaging may be disposed with the regular household refuse 4 2...

Page 14: ...e 5 on the firing plate holder 48 Secure the cooling tray 34 with the two screws 35 including the silicone rest 47 Place the cooling tray 34 on the frame plate 7 Make sure that the cooling tray 34 is...

Page 15: ...ace head mounting 43 Ensure that the furnace head mounting mark 41 is aligned with the furnace base mounting mark 42 Make sure that the firing plate 5 is not damaged by mounting the furnace head Step...

Page 16: ...itional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 16 with the power socket 17 of the furn...

Page 17: ...d 16 with the wall socket 2 Put the On Off switch 11 at the rear of the furnace on position I The furnace will now automatically conduct a self test The performance of all furnace components is automa...

Page 18: ...n menu The right key can be used to navigate between the settings and auxiliary programs Cursor keys 79 80 The current cursor position is indicated by means of a fix non blinking frame around the valu...

Page 19: ...uration and information 5 4 Adjustable parameters and possible value ranges Symbol Parameter Value range Value range P Program number P 1 100 B Stand by temperature 100 700 C 212 1292 F S Closing time...

Page 20: ...ntered by using the numeric keys The date can be selected by using the numeric keys Settings Write protection Ivoclar Vivadent optimized temperature control function Pre drying Vacuum test program Hea...

Page 21: ...reset to 0 Only after entry of the user code Settings Serial number Software version Furnace head firing hours Operating hours furnace Operating hours vacuum pump Latest start of calibration program...

Page 22: ...ox 10 seconds with the beeper signal set by the user If the STOP key is not pressed during this time the beeper sounds again after 5 minutes for a period of 5 minutes Subsequently there will be no fur...

Page 23: ...priate symbol first or second stage Two stage program stage 1 is shown stage 2 is shown If the cursor is positioned on the one stage symbol and the symbol is switched to the two stage symbol by pressi...

Page 24: ...ttom line until the next value is entered and successfully confirmed or the process is aborted with ESC The old valid value reappears Please refer to the parameter details for the value range 6 4 2 Pr...

Page 25: ...on the surface of the insulation are harmless and do not influence the function of the furnace in a negative fashion weekly Thermocouple 4 Check if the thermocouple is straight and in the right place...

Page 26: ...s the ENTER key The following is displayed c Insert silver wire into the Ivoclar Vivadent sample holder d Place the sample holder with the silver strip in the centre of the firing plate 6 e Press STAR...

Page 27: ...local Ivoclar Vivadent Service Center 13 System Heating muffle very old 23 The heating muffle is very old It is recommended to replace it After the error message has been acknowledged a firing program...

Page 28: ...ng program from the The program could not be continued since the USB memory stick is no longer present memory stick in progress memory stick no longer present 40 System Prolonged power failure 704 An...

Page 29: ...ure 69 System Reading calculating the 1204 no Error while measuring the furnace control temperature furnace control temperature 70 System Reading caluclating the 1205 Error while measuring the resista...

Page 30: ...and on again If it still does not work properly contact your local Ivoclar Vivadent Service Center Vacuum pump does not start working Is the vacuum pump fuse defective Check fuse and replace if necess...

Page 31: ...e Depth 368 mm width 303 mm 398 mm with Cooling tray Height 320 mm Usable size of the firing chamber Diameter 80 mm Height 48 mm Max firing temperature 1200 C 2192 F Weight Furnace base 12 3 kg Furnac...

Page 32: ...local Service Center Important information The current program table is also available at www ivoclarvivadent com The program tables can be downloaded from the Internet as PDF files Please make sure t...

Page 33: ...66 77 80 www ivoclarvivadent it Ivoclar Vivadent S A de C V Av Mazatl n No 61 Piso 2 Col Condesa 06170 M xico D F Mexico Tel 52 55 5062 1000 Fax 52 55 5062 1029 www ivoclarvivadent com mx Ivoclar Viv...

Reviews: