17
4.5.8 Alarm Out
<Channel>: Allow setup name for choosing channel
<Valid period of time>: Setup alarm output time period. + mean valid
period, - mean except the period
4.5.9 PTZ
<Video Channel>: Choose video channel.
<Address>: Matching the PTZ address with protocol.
<Protocol>: Support Pelco-D & Pelco-P,
default
is
Pelco-D
.
<Step Length>: Range 1~64, default 32.High speed will make the
control hard; suggest under 32 for high speed dome.
<Comm Setting>: Set baud rate, data bit, stop bit, verify bit.
4.5.10 Video Channel
<Channel>: Choose the channel.
<Name>: Setup the channel name.
<Resolution>: 4 kinds: QCIF / CIF / Half_D1 / D1.
<PAL/NTSC>: Choose PAL or NTSC.
4.5.11 Audio Channel
<Channel Number>: Choose the channel No.
<Bits Width>: 8bits / 16bits / 32bits for optional.
< Sampling Rate >: The effect will better with frequency increase.
<Compression>: Choose different mode to compress audio steam (about
10 times).
Notice: Suggest keep the default setting in normal. Just click
open talkback and voice function.
4.5.12 User Management
User management is use to add, delete or modify user name and password,
and setup corresponding authority. User name can only be English character
Summary of Contents for CZ-537-IP
Page 1: ...Rev 3 2 2012 CZ 537 IP IR Night Vision Network PTZ Cameras...