background image

 

Rev. 3-2-2012 

 

 

CZ-537-IP IR Night Vision   

Network PTZ

 Cameras

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for CZ-537-IP

Page 1: ...Rev 3 2 2012 CZ 537 IP IR Night Vision Network PTZ Cameras...

Page 2: ...struction 6 4 2 Main Interface 6 4 3 Toolbar 9 4 3 1 Image Quality 11 4 3 2 OSD 12 4 3 3 Shelter 12 4 3 4 Motion Detection 12 4 4 Setting 13 4 4 1 Client Setup 13 4 4 2 Video Switch Setting 13 4 4 3 L...

Page 3: ...19 4 8 Router configuration 19 4 9 IE mode 19 5 How to Use OSD Menu 20 5 1 Basic operation of Main menu 20 5 2 Main Menu 21 5 2 1 System Information 22 5 2 2 Address Setting 22 5 2 3 Motion 23 5 2 4 P...

Page 4: ...ments for this product Please check the space and toughness of the site before installing It should be able to bear 4 times the weight of the dome and its accessories Please keep all the original dome...

Page 5: ...arking action power up action etc IP Function H 264 video compression format Support CIF D1 format Support mobile RS485 alarm intercom and monitor interface Support SMTP could send the picture in the...

Page 6: ...Preset 254 Pan Scan frame scan 360 random scan 360 continuous scan Pattern 4 Cruise 3 OSD Menu Chinese English IR Illumination ON OFF option IR Distance 20m Baud Rate 2400bps 4800bps 9600bps auto adap...

Page 7: ...ng Sony camera module compatible 38 38 CCD with fixed focus lens 3 Installation Instruction 3 1 Installation A Fixed the ceiling installation board with supplied screws The board dimension as shows B...

Page 8: ...5 3 2 System Connection 3 3 Dip Switch Setup Dip Switch as follows Notice Dip Switch Address Setup see appendix I...

Page 9: ...2G or Higher recommended RAM 256 MB or more Color Monitor At least DirectX 8 1 or higher and 32M Display storage HD More than 40G Double click the Program of Client Software Package to install the sof...

Page 10: ...software to open the surveillance picture Steps are following 1 Click the right side Devices button will pop up Note If the device is not in the same network segment Client could auto search but cann...

Page 11: ...oxy 3 Input the IP Host for example the IP Host is testdvs3322 org and port is 8001 the Host chooses DVS IP CAM click OK 4 Double click the device list and then pop out the connected window input the...

Page 12: ...9 4 3 Toolbar From Left to right Information Talkback Sound Snapshot Record Color Setup Flip Rotate and Open Zoom Focus Iris Preset Point Cruise Tracks...

Page 13: ...Navigation Zoom In Out Focus Iris Preset Point Edit Cruise track Stop Cruise Devices Property Disconnect Save Delete Scene Cruise Tracks Display channels support 1 4 6 8 9 12 16 20 25 30 window displ...

Page 14: ...Up limit When the coding stale is Rate first the actual coding would not exceed the value The default value is 1024kps Frame rate It means the frames per second in the video The value range from 1 25...

Page 15: ...select shelter area click Clear key to clear the shelter 4 3 4 Motion Detection Motion detection setup Hold Ctrl to select the detection area at most 4 areas could be set Sensitivity The value is larg...

Page 16: ...or decrease the pages Click Stay turn up and down to increase or decrease the time for staying Click the layout window to set the display mode press and hold the left mouse button to drag the right si...

Page 17: ...click pop to switch 4 4 7 Full Screen Click change to full screen mode all action will be locked under this mode input administrator password when quit Click the right button to pop 4 5 Device proper...

Page 18: ...DNS for unfixed IP domain name mapping This client software support peanut shell and 3322 DDNS Service Just apply your domain name in the proper network station refer to Part 4 7 then click OK in the...

Page 19: ...ount related password Receiver s Account Any mailbox which can receive mail Click Send A Test Mail after setup to confirm your action Notice For outlook or foxmail user need set the sender account to...

Page 20: ...it verify bit 4 5 10 Video Channel Channel Choose the channel Name Setup the channel name Resolution 4 kinds QCIF CIF Half_D1 D1 PAL NTSC Choose PAL or NTSC 4 5 11 Audio Channel Channel Number Choose...

Page 21: ...ice will auto restart after upgrade User can check current version no here Current version Display current version not allow edit File to upload Click Open find the file then click Upload the followin...

Page 22: ...input domain in the network browser can run Client 4 7 Application for DDNS Normally users use dynamic IP address in the internet User can use a static hostname instead of a dynamic IP address to moni...

Page 23: ...f Main menu Go Preset 95 enter into main menu Using Iris open and Iris close to confirm or exit main menu Using UP DOWN keys or joystick to move cursor to sub menu press Iris open to enter into menu U...

Page 24: ...ettings PATTERNS Setup for Patterns CAMERA Configure Camera related functions and data CRUISE SETTING Setup presets scan IR SETTING Setting IR ON OFF SENS DISPLAY SETUP Enable Disable of OSD display o...

Page 25: ...TYPE Choose the address type Hard Soft Add when you choose soft type the user can setup the address by remote access ADDR SOFT Setup soft address The camera ID can be set from 0 255 ADDR HARD Setup ha...

Page 26: ...to SET SCAN POSITION and enter below interface 2 Move the cursor to choose the extreme position of preset by using Left Right keys or joystick of your controller then press Iris Open to SET FRAME SCA...

Page 27: ...sitions 5 2 4 Patterns PATTERN NUMBER Set Pattern number 1 4 PROGRAM PATTERN Pattern scan program CLEAR CURRENT PATTERN Deletes data in current pattern PATTERNS PATTERN NUMBER 1 PROGRAM PATTERN CLEAR...

Page 28: ...LABEL press Iris Open to enter sub menu and edit camera label Using cursor to select the letter then press Iris Open key to save the setup CAMERA LABEL ABCDEFGHIJKLMNO PQRSTUVWXYZ a b c d e f g h I j...

Page 29: ...and Blue level manually Red adjust range 0 100 Blue adjust range 0 100 3 Auto BW This mode is the most accurate and reliable for most places BACKLIGHT COMPENSATION Backlight High Middle Low Off MOTIO...

Page 30: ...ocus and fix the status till the image change again Notice Do not use Auto Focus under the below conditions The target is too dark such as black clothes or curtains FOCUS MODE AUTO ZOOM TRACE MODE ON...

Page 31: ...enlarge or downsize press Iris Open key to back One off Auto focus and Manual focus Adjustment ZOOM TRACE MODE Manual Focus Off Auto and One off Auto Focus On Off ZOOM TRACE SPEED Fast Slow DIGITAL Z...

Page 32: ...s Open to enter into manual setup If the number of iris is set to higher the image will be brighter SHUTTER Shutter Mode Flicker Manual Auto The shutter speed of Anti flash is 1 100 NTSC 1 120 PAL Man...

Page 33: ...f Manual Enhances image brightness automatically in case that luminance level of image signal is too low Range 5 41 SSNR High Middle Low Off Enhances images by reducing noises when gain level of image...

Page 34: ...se direction keys to On and press Iris Open to setup USER PRESET MODE FOCUS EXPOSURE OTHER EXIT USER PRESET USER PRESET NUMBER NO 1 USER PRESET MODE OFF SAVE CLEAR EXIT PRESET NOT SETUP ADDITIONAL MEN...

Page 35: ...up OTHER refer to below details OTHER CAMERA TYPE OFF BW AUTO TRACE BW BLC OFF MOTION DETECTION OFF PRIVACY MASK OFF DAY NIGHT OUTER HORIZONTAL FLIP OFF VERTICAL FLIP OFF EXIT FOCUS MODE AUTO ZOOM TR...

Page 36: ...side RIGHT horizontal abscissa position on the left side DAY NIGHT Day and Night function Auto 1 Auto 2 Outer Color B W mode B W MODE suit for night work COLOR MODE suit for daytime AUTO MODE change d...

Page 37: ...ip 180 when you start up Normal when shutdown VERTICAL FLIP image will flip 180 when you start up and normal when shutdown SHARPNESS adjust the sharpness of the edges Range 0 31 HUE adjust the image h...

Page 38: ...t IR light value higher than setting IR light value 81 254 could be optional IR OFF SENS IR OFF automatically when current IR light value IR SETTING IR MODE AUTO IR ON SENS 110 IR OFF SENS 90 BACK EXI...

Page 39: ...tes refer to the monitor centre BRIGHT DATA Show or hide IR light value Use direction key of CCTV Tester to modify preset and confirm by press Iris Open key 5 2 9 Restore Factory Default Move cursor t...

Page 40: ...h according to the DIP switch chart 2 Check 485 bus controls 3 Check the wiring 4 Check the control device Some function is out of control 1 RS485 communication signal is not balance 2 Control protoco...

Page 41: ...s CALL 84 Start pattern 1 CALL 85 Start pattern 2 CALL 86 Start pattern 3 CALL 87 Start pattern 4 CALL 88 Start preset 1 10 cruise CALL 89 Start preset 11 20 cruise CALL 99 Start preset 1 20 cruise Ma...

Page 42: ...7 8 1 1 0 0 0 0 0 0 0 2 0 1 0 0 0 0 0 0 3 1 1 0 0 0 0 0 0 4 0 0 1 0 0 0 0 0 5 1 0 1 0 0 0 0 0 6 0 1 1 0 0 0 0 0 7 1 1 1 0 0 0 0 0 8 0 0 0 1 0 0 0 0 9 1 0 0 1 0 0 0 0 10 0 1 0 1 0 0 0 0 11 1 1 0 1 0 0...

Page 43: ...1 0 0 59 1 1 0 1 1 1 0 0 60 0 0 1 1 1 1 0 0 61 1 0 1 1 1 1 0 0 62 0 1 1 1 1 1 0 0 63 1 1 1 1 1 1 0 0 64 0 0 0 0 0 0 1 0 65 1 0 0 0 0 0 1 0 66 0 1 0 0 0 0 1 0 67 1 1 0 0 0 0 1 0 68 0 0 1 0 0 0 1 0 69...

Page 44: ...1 0 0 0 1 1 1 0 114 0 1 0 0 1 1 1 0 115 1 1 0 0 1 1 1 0 116 0 0 1 0 1 1 1 0 117 1 0 1 0 1 1 1 0 118 0 1 1 0 1 1 1 0 119 1 1 1 0 1 1 1 0 120 0 0 0 1 1 1 1 0 121 1 0 0 1 1 1 1 0 122 0 1 0 1 1 1 1 0 123...

Page 45: ...1 167 1 1 1 0 0 1 0 1 168 0 0 0 1 0 1 0 1 169 1 0 0 1 0 1 0 1 170 0 1 0 1 0 1 0 1 171 1 1 0 1 0 1 0 1 172 0 0 1 1 0 1 0 1 173 1 0 1 1 0 1 0 1 174 0 1 1 1 0 1 0 1 175 1 1 1 1 0 1 0 1 176 0 0 0 0 1 1 0...

Page 46: ...1 221 1 0 1 1 1 0 1 1 222 0 1 1 1 1 0 1 1 223 1 1 1 1 1 0 1 1 224 0 0 0 0 0 1 1 1 225 1 0 0 0 0 1 1 1 226 0 1 0 0 0 1 1 1 227 1 1 0 0 0 1 1 1 228 0 0 1 0 0 1 1 1 229 1 0 1 0 0 1 1 1 230 0 1 1 0 0 1 1...

Page 47: ...44 253 1 0 1 1 1 1 1 1 254 0 1 1 1 1 1 1 1 255 1 1 1 1 1 1 1 1 Notice some protocols and address start from 0 if you can not control the dome camera try to do 1 of address code...

Page 48: ......

Reviews: