8
Protocol: Pelco-D.
2.2.1 Camera ID Setup
The range of ID is 0~255. Factory default of Camera ID is 1.
ID number of camera is set using binary number. The number from 1~8
present 1, 2, 4, 8, 16, 32, 64, 128. For example, switch 1, 3, 5, 7 to “ON”
position, the corresponding ID should be 1+4+16+64=85.
The example is shown bellow.
ID No
Code Switch
ID No
Code Switch
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
0
0 0 0 0 0 0 0 0
10
0 1 0 1 0 0 0 0
1
1 0 0 0 0 0 0 0
20
0 0 1 0 1 0 0 0
2
0 1 0 0 0 0 0 0
30
0 1 1 1 1 0 0 0
3
1 1 0 0 0 0 0 0
50
0 1 0 0 1 1 0 0
4
0 0 1 0 0 0 0 0
100
0 0 1 0 0 1 1 0
5
1 0 1 0 0 0 0 0
101
1 0 1 0 0 1 1 0
6
0 1 1 0 0 0 0 0
150
0 1 1 0 1 0 0 1
7
1 1 1 0 0 0 0 0
200
0 0 0 1 0 0 1 1
8
0 0 0 1 0 0 0 0
255
1 1 1 1 1 1 1 1
2.2.2 Communication Protocol and Baud rate Setup