Important
If you want the system to show load weight in pounds, use the known calibration
load weight
in pounds
during the system calibration and enter that value accordingly. The same would
apply if you want the system to show load weight in kilograms then use the known calibration
load weight in kilograms
and enter that value into the system accordingly.
Calibration starting point
Lower the empty forks to the ground.
There should be no hydraulic
pressure in lift hydraulic circuit.
- Turn ignition switch to on position and start the engine
- LED display will show software version on the right side and number
8
will be
shown in
Mode
window.
Calibration of empty forks being lifted just above
the ground
To initiate calibration press the
“M”
button (use a paper clip) and hold
it down for approx. 5 seconds until
Mode digit 8 changes to 0
.
System is ready for automatic zeroing of the scale function
When LED display is showing “0” in Mode digit, lift the
empty forks
just above the ground
to automatically
calibrate zero value for empty forks being lifted.
Activate the lift control valve as you would do during the
normal lifting operation. Do not attempt to lift the
empty forks slowly.
After few seconds, LED display will show
“1”
in Mode digit and
“0”
value in furthest right digit display.
(Instead of 0 value it could be any other number from 0 to 9, depending
on previous calibrated load weight entered into the system)
Automatic zeroing is done!
Note: